The multifunctional plastic automatic chiller has a high degree of automation, compact structure, beautiful appearance, convenient use, and energy saving.
Multi functional plastic automatic chillerFeatures:
1. Stable performance: Multiple compressors are used in parallel, each compressor comes with an independent refrigeration circuit, that is, the evaporator and condenser are also independent; All compressors are commanded by a unified microcomputer control system, and they are turned on and off one by one without interfering with each other. In addition, all machines of this brand are made of original genuine products, and the single machine failure rate is extremely low. Considering the above reasons, this series of machines can ensure highly stable performance.
2. Energy saving: Multiple small and medium power compressors are used in parallel, with minimal interference to the power grid during start-up and shutdown. As the load changes, the unit automatically determines the number of compressors to be started, ensuring that the compressors are in working condition and effectively saving electricity.
3. Long service life: The evaporator and condenser are designed very reasonably and placed above the compressor. Throughout the entire operation, the vast majority of lubricating oil stays inside the compressor, ensuring good lubrication of the compressor.
Notes:
1. Check whether the industrial chiller is damaged before installation.
2. In order to facilitate future use and maintenance, the site for installing industrial chillers must be a flat surface.
3. Industrial chillers should be placed in ventilated and temperature controlled machine rooms. In winter, if the temperature is too low, antifreeze should be added.
4. Choose the appropriate pipe diameter for the cooling system and chilled water system during high-power operation of the chiller, and connect them correctly.
5. For ordinary applications, the water flow velocity through the evaporator and condenser is approximately between 1-8m/s.
6. Under any load condition, the water flow rate should remain stable.
7. After the leak test is completed, all the connecting ports of the chiller must be treated with rust prevention.
Multi functional plastic automatic chillerMaintenance work:
1. Place the chiller in a ventilated and cool place for use, preferably below 40 degrees Celsius.
2. Regularly clean the condenser and dust screen of the chiller to prevent dust accumulation.
3. Regularly replace the circulating cooling water, and clean the water tank regularly, usually every 3 months.
4. The quality and temperature of circulating water can affect the service life of laser tubes. It is recommended to use deionized water and control the water temperature at around 25 degrees Celsius.
5. When using a UV laser chiller, the machine room should be kept clean and well ventilated, and the condenser should be cleaned regularly to ensure the normal operation of the unit.
6. When the unit malfunctions and alarms for shutdown, the alarm shutdown button should be pressed first, and then the cause of the fault should be checked. Remember not to forcefully start the machine before troubleshooting.
7. If there is no emergency situation during use, do not shut down the unit by cutting off the power supply at will; If the unit is not used for a long time in winter, turn off the unit first, then turn off the main power, and drain the water in the ultraviolet laser chiller.