injection molding machine control systemFault (motor starting circuit, controller))
Motor starting circuit
Fault phenomenon1 Occasionally appearing when powered on“E.OC
Reason for malfunction1 Motor malfunction, later confirmed to be caused by a mouse bite on the coding line and signal feedback deviation leading to motor malfunction
Solution Normal after disassembling and repairing the motor
Fault phenomenon2 The motor trips immediately after starting, and the panel displays servo control abnormality, while the frequency converter alarm displays“E.EF”
Reason for malfunction2 The cause of the malfunction is due to "abnormal servo control", and upon inspection of the circuit, it was found thatB34The 'servo controller' point has no input, this input point is damaged.
Solution After replacing the input point, the fault was resolved
Fault phenomenon3 Flow setting59The above motor is overloaded
Reason for malfunction3 After removing the contactor, it was found that two pairs of contacts were burnt out
Solution Troubleshooting after replacing the new contactor
Fault phenomenon4 Power on pressure50arrive
Reason for malfunction4 B+Exposed copper wire, caused by touching the shell
Solution Which one may be observed for a few hours normally
Fault phenomenon5 The device will sound an alarm when the new machine is turned on
Reason for malfunction5 HPC09The output socket of the power board is not securely plugged in, resulting in voltage loss
Solution Twist off some parts with diagonal pliersPVCCable tray, reconnect, power on, normal
Fault phenomenon6 The motor cannot start
Reason for malfunction6 The computer board is not outputting
Solution Repair or replace the computer board
Fault phenomenon7 The motor cannot start
Reason for malfunction7 The communication contactor is broken
Solution Replace the AC contactor
Fault phenomenon8 The motor cannot start
Reason for malfunction8 Thermal protection relay or thermistor protection fault
Solution Replace the thermal protection relay and thermistor, normal
controller
Fault phenomenon1 Press the motor start button, the button light will turn on, but the motor cannot start
Reason for malfunction1 On the computer board220VThe fuse is burnt out
The solution is normal after replacement
Fault phenomenon2 As soon as the motor starts, there is pressure on the system pressure gauge
Reason for malfunction2 Proportional pressure and flow rate10VVoltage, circuit board malfunction
Solution Bring the circuit board back for repair
Fault phenomenon3 After program version change, semi-automatic loop1-5The module crashes due to unequal waiting time
Reason for malfunction3 Program issue, internal parameter usageSTAN4B1Caused by
Solution Enter the parameter screen and change the parameters again. Follow this method and there was no crash, indicating successful program transmission.
Fault phenomenon4 The screen displays' Please contact Haitian '
Reason for malfunction4 Panel(S7)Problem solution: The computer board needs to be repaired
Fault phenomenon5 Screen display in English (alarm, Fuji)09Computer)
Reason for malfunction5 Incorrect selection of a micro switch (analog) on the Fuji expansion board
Solution Adjust the position of the micro switch again
Fault phenomenon6 Alarm 'action timeout', switch to heating and motor
Reason for malfunction6 Computer internal parameter selection error
Solution Adjust the computer(HPC09)Internal parameters, no need to select 'energy-saving'
Fault phenomenon7 Reason for computer crash malfunction7 Circuit board damage
Solution Normal after replacing the circuit board
Fault phenomenon8 Manual light not on, LCD not displaying
Reason for malfunction8 Solution for broken computer board: The computer board needs to be repaired
Fault phenomenon9Manual light not on, LCD not displaying
Reason for malfunction9 Bipolar switch(380V)Jump away
Solution Normal after closing again
Fault phenomenon10 LCD white screen, no text
Reason for malfunction10 CPUBoard malfunction
Solution brought back for repair
Fault phenomenon11 After turning off the main power and restarting, the original parameters will change
Reason for malfunction11 The panel does not have a memory function
Solution: The computer board needs to be repaired
Fault phenomenon12 High proportional current, uncontrolled action
Reason for malfunction12 The locator for the proportional current of the computer board needs to be adjusted
Solution Adjust the locator, the action is normal
Fault phenomenon13 After booting up, the proportional current reaches its maximum value, and the server alarms
Reason for malfunction13 The computer board is broken and the proportional current output is at its maximum, causing the server to overload
Solution Repair computer board (can be repaired on-site)
Fault phenomenon14 The locator for adjusting the proportional current cannot adjust the current properly
Reason for malfunction14 The neutral wire is electrified
Solution Re ground and check the peripheral circuit
Fault phenomenon15 The actual positions of the switch mold, injection, and ejection actions remain unchanged0
Reason for malfunction15Motherboard(AK668)Bad
Solution: The computer board needs to be repaired
Fault phenomenon16 When fully automatic, there is a significant impact during the seat movement.
Reason for malfunction16 After high-pressure mold locking, the pressure did not release, but the inlet valve of the seat has been opened, causing
Solution Turn off the system parameter delay from the original0.05change to2The machine is running normally
Fault phenomenon17 Sometimes there is no action when pressing the button
Reason for malfunction17 Multiple buttons sometimes have poor contact
Solution: Replace some buttons
Fault phenomenon18 Traffic in15-25There is no movement between the machines
Reason for malfunction18 There is an issue with the linearity of traffic
Solution After readjusting the internal parameters of the computer, it returned to normal
Fault phenomenon19 During normal production, the computer will restart
Reason for malfunction19 There is an issue with the panel
Solution: The computer board needs to be repaired
Fault phenomenon20 All the movements of the machine have slowed down
Reason for malfunction20 Abnormal proportional current
Normal after adjusting the solution
warranty
New products are guaranteed for one year;For all products and projects that we repair or sell (old parts), we offer a three-month full warranty (i.e. we provide warranty for any type of malfunction during the warranty period). In case of special circumstances, we will communicate with you clearly before the repair. Let you understand and consume with peace of mind.
support
When both of us have already understood each other and you have a certain amount of transactions every month, during the maintenance period of your repair products, as long as we have the same model of finished products in stock, we can lend them to you for free until your repair products are repaired; Whether you have worked with us or not, if you have any technical issues, you can consult us for free by phone, and we will do our best to assist you in solving the problem.
contact information
Dongguan Kesichuang CNC Technology Co., Ltd
Phone:/
Fax:
contacts:
contacts:
Office Address: Guoxin Commercial Building, Yunhe East Third Road, Nancheng, Dongguan City702chamber