Computer maintenance of Nippon Steel injection molding machine

NegotiableUpdate on 02/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Computer maintenance of Nippon Steel injection molding machine
Product Details




Computer maintenance of Nippon Steel injection molding machine



injection molding machine control systemFault (Controller)


controller

Fault phenomenon1 Press the motor start button, the button light will turn on, but the motor cannot start

Reason for malfunction1 On the computer board220VThe fuse is burnt out

The solution is normal after replacement

Fault phenomenon2 As soon as the motor starts, there is pressure on the system pressure gauge

Reason for malfunction2 Proportional pressure and flow rate10VVoltage, circuit board malfunction

Solution Bring the circuit board back for repair

Fault phenomenon3 After program version change, semi-automatic loop1-5The module crashes due to unequal waiting time

Reason for malfunction3 Program issue, internal parameter usageSTAN4B1Caused by

Solution Enter the parameter screen and change the parameters again. Follow this method and there was no crash, indicating successful program transmission.

Fault phenomenon4 The screen displays' Please contact Haitian '

Reason for malfunction4 Panel(S7)Problem solution: The computer board needs to be repaired

Fault phenomenon5 Screen display in English (alarm, Fuji)09Computer)

Reason for malfunction5 Incorrect selection of a micro switch (analog) on the Fuji expansion board

Solution Adjust the position of the micro switch again

Fault phenomenon6 Alarm 'action timeout', switch to heating and motor

Reason for malfunction6 Computer internal parameter selection error

Solution Adjust the computer(HPC09)Internal parameters, no need to select 'energy-saving'

Fault phenomenon7 Reason for computer crash malfunction7 Circuit board damage

Solution Normal after replacing the circuit board

Fault phenomenon8 Manual light not on, LCD not displaying

Reason for malfunction8 Solution for broken computer board: The computer board needs to be repaired

Fault phenomenon9Manual light not on, LCD not displaying

Reason for malfunction9 Bipolar switch(380V)Jump away

Solution Normal after closing again

Fault phenomenon10 LCD white screen, no text

Reason for malfunction10 CPUBoard malfunction

Solution brought back for repair

Fault phenomenon11 After turning off the main power and restarting, the original parameters will change

Reason for malfunction11 The panel does not have a memory function

Solution: The computer board needs to be repaired

Fault phenomenon12 High proportional current, uncontrolled action

Reason for malfunction12 The locator for the proportional current of the computer board needs to be adjusted

Solution Adjust the locator, the action is normal

Fault phenomenon13 After booting up, the proportional current reaches its maximum value, and the server alarms

Reason for malfunction13 The computer board is broken and the proportional current output is at its maximum, causing the server to overload

Solution Repair computer board (can be repaired on-site)

Fault phenomenon14 The locator for adjusting the proportional current cannot adjust the current properly

Reason for malfunction14 The neutral wire is electrified

Solution Re ground and check the peripheral circuit

Fault phenomenon15 The actual positions of the switch mold, injection, and ejection actions remain unchanged0

Reason for malfunction15Motherboard(AK668)Bad

Solution: The computer board needs to be repaired

Fault phenomenon16 When fully automatic, there is a significant impact during the seat movement.

Reason for malfunction16 After high-pressure mold locking, the pressure did not release, but the inlet valve of the seat has been opened, causing

Solution Turn off the system parameter delay from the original0.05change to2The machine is running normally

Fault phenomenon17 Sometimes there is no action when pressing the button

Reason for malfunction17 Multiple buttons sometimes have poor contact

Solution: Replace some buttons

Fault phenomenon18 Traffic in1525There is no movement between the machines

Reason for malfunction18 There is an issue with the linearity of traffic

Solution After readjusting the internal parameters of the computer, it returned to normal

Fault phenomenon19 During normal production, the computer will restart

Reason for malfunction19 There is an issue with the panel

Solution: The computer board needs to be repaired

Fault phenomenon20 All the movements of the machine have slowed down

Reason for malfunction20 Abnormal proportional current

Normal after adjusting the solution



warranty

New products are guaranteed for one year;For all products and projects that we repair or sell (old parts), we offer a three-month full warranty (i.e. we provide warranty for any type of malfunction during the warranty period). In case of special circumstances, we will communicate with you clearly before the repair. Let you understand and consume with peace of mind.

support

When both of us have already understood each other and you have a certain amount of transactions every month, during the maintenance period of your repair products, as long as we have the same model of finished products in stock, we can lend them to you for free until your repair products are repaired; Whether you have worked with us or not, if you have any technical issues, you can consult us for free by phone, and we will do our best to assist you in solving the problem.

contact information

Dongguan Kesichuang CNC Technology Co., Ltd

Phone:/

Fax:

contacts:a weaponMr./

contacts:kingMiss/

Office Address: Guoxin Commercial Building, Yunhe East Third Road, Nancheng, Dongguan City702chamber