injection molding machine control systemFault (electrical main circuit, frequency converter))
Main electrical circuit
Fault phenomenon1 The motor can start without any action, and the number of the frequency converter remains unchanged
cause of failure1 No feedback signal from pressure sensor
Solution Pressure sensors andJ5The wiring between the boards is loose, but after tightening, it is normal
Fault phenomenon2 During the production process, the main switch often trips
cause of failure2 MAThe machine configuration leakage switch must be equipped with a dedicated switch
Solution Temporarilyru38(Carrier frequency),Originally for4change to2)After observation, there was no further tripping. The final configuration requires a current greater than300MAThe leakage switch.
Fault phenomenon3 The motor can start, the ammeter shows current, but the machine does not move
cause of failure3 Enable no
Solution The relay has poor contact, but after replacing the contacts, it returned to normal
Fault phenomenon4 The position ruler data fluctuates greatly
cause of failure4 Communication connection issue
Solution Turn off the power, unplug the communication cable, and then power on again. The position gauge data is normal and all actions are normal
Fault phenomenon5 The machine has no movement
cause of failure5 Flow proportional valve ammeter current none
Solution The plug of the flow valve coil is loose, but it works normally after being plugged in
Fault phenomenon6 Manual light not on, LCD not displaying
cause of failure6 Peripheral phase loss, fuse broken
Solution Normal after replacing the fuse
Fault phenomenon7 The machine cannot operate, and there is an abnormal alarm in the safety circuit
cause of failure7 The safety relay is broken
Solution Need to replace the safety relay
Fault phenomenon8 All temperatures are displayed988
cause of failure8 Peripheral phase loss, faulty air switch
Solution Normal after replacing the air switch
Inverter (Huichuan)
Fault phenomenon1 When the pressure is relatively high, the pressure gauge will shake
cause of failure1 Unreasonable internal parameter settings of the frequency converter
Solution Normal after modifying the internal parameters of the frequency converter
Fault phenomenon2 Display "servo controller abnormal" alarm
cause of failure2 The zero position of the frequency converter is incorrect
Solution The frequency converter returns to normal after resetting to the zero position
Fault phenomenon3 All movements are relatively slow
cause of failure3 Remove the frequency converter and replace it with a power frequency connection
Solution for normal production
Fault phenomenon4 After a period of production, the frequency converter will appearOH2call the police
cause of failure4 The solution is that the peripheral waterway has not been properly connected Normal after adjusting the waterway
Fault phenomenon5 Inverter overheating alarm,E.OHcall the police
cause of failure5 The waterway is blocked and the cooling water is not turned on
Solution Normal operation after opening the cooling water
Fault phenomenon6 Inverter overtemperature alarm
cause of failure6 The frequency converter is broken
Solution Repair or replace the frequency converter
warranty
New products are guaranteed for one year;For all products and projects that we repair or sell (old parts), we offer a three-month full warranty (i.e. we provide warranty for any type of malfunction during the warranty period). In case of special circumstances, we will communicate with you clearly before the repair. Let you understand and consume with peace of mind.
support
When both of us have already understood each other and you have a certain amount of transactions every month, during the maintenance period of your repair products, as long as we have the same model of finished products in stock, we can lend them to you for free until your repair products are repaired; Whether you have worked with us or not, if you have any technical issues, you can consult us for free by phone, and we will do our best to assist you in solving the problem.
Contact Information
Dongguan Kesichuang CNC Technology Co., Ltd
Phone:/
Fax:
Contact Person:
Contact Person:
Office Address: Guoxin Commercial Building, Yunhe East Third Road, Nancheng, Dongguan City702room