CQ Engineering Plastic Magnetic Pump

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
CQ Engineering Plastic Magnetic Pump
Product Details

CQ Engineering Plastic Magnetic Pump


Detailed information on CQ engineering plastic magnetic pump:
1、 Product Overview of CQ Engineering Plastic Magnetic Pump:
CQ engineering plastic magnetic drive pump (i.e. magnetic pump) applies modern magnetic principles, uses internal and external magnetic steel push-pull transmission, and uses an isolation sleeve in the middle of the magnetic circuit to seal the liquid inside the isolation sleeve, replacing dynamic sealing with static sealing, completely solving the problems of running, emitting, dripping, and leaking that other pump mechanical seals cannot avoid. This pump is made of reinforced polypropylene, steel jade ceramics, PTFE graphite and other materials, and can be widely used in chemical, pharmaceutical, petroleum, electroplating, food, film photography and printing, material research institutions, national defense industry and other units to pump acids, alkalis, oils, rare and valuable liquids, venoms, volatile liquids, etc. This pump is more ideal.
2、 CQ Engineering Plastic Magnetic Pump Product Features:
Magnetic pumps replace dynamic seals with static seals, ensuring that the overcurrent components of the pump are in a completely sealed state, completely solving the problems of running, emitting, and dripping that cannot be avoided by other pump mechanical seals. Magnetic pumps use corrosion-resistant and high-strength engineering plastics, corundum ceramics, stainless steel, and other materials as manufacturing materials, so they have good corrosion resistance and can protect the transported medium from pollution.
The overcurrent components are made of corrosion-resistant materials such as colored stainless steel, high-density carbon, high-purity alumina ceramics, and filled with polytetrafluoroethylene. With a leak free sealing structure design, they ensure the safe transportation of chemical fluids.
The maximum efficiency of the pump reaches 50-55%, and the design process of the pump fully considers energy conservation.
The structure is simple, with modular main components for easy and quick disassembly and inspection. Vulnerable parts can be replaced separately.
3、 CQ Engineering Plastic Magnetic Pump Product Usage:
CQ engineering plastic magnetic drive pump is made of corrosion-resistant, high-strength stainless steel, engineering plastic silicon nitride ceramics and other materials. Suitable for pumping acid, alkali, oil, venom, rare and valuable liquids, volatile liquids, and supporting circulating water equipment in petroleum, chemical, pharmaceutical, electroplating, environmental protection, food, water treatment research institutions, national defense industry and other units. This pump is particularly suitable for pumping liquids that are prone to leakage, flammable, and explosive, making it an ideal choice.
CQ engineering plastic magnetic drive pump has the advantages of simple structure, beautiful appearance, small volume, low noise, smooth operation, easy use and maintenance. Divided into two categories based on material: stainless steel and engineering plastics. Plastic components are all injection molded, resulting in high production efficiency, low processing costs, and a highly competitive price advantage. It is currently the most widely used leak free pump

CQ EngineeringPlastic magnetic pumpPerformance parameters:

Model number
Caliber (mm)
internet traffic
(m3/h)
lift
(m)
npsh
(NPSH)r(m)
Motor Power
(KW)
rotational speed
(r/min)
supply voltage
(V)
Import
Export
10CQ-3
10
8
0.9
3
7.8
0.010
2900
220
14CQ-5
14
10
1.2
5
7.0
0.12
220/380
16CQ-8
16
10
1.8
8
6.0
0.18
20CQ-12
20
15
2.5
12
6.0
0.37
25CQ-15
25
20
5.4
15
5.0
1.1
380
32CQ-15
32
25
6.5
15
6.0
1.1
32CQ-25
32
25
4.8
25
5.5
1.1
40CQ-20
40
32
10.8
20
3.5
2.2
50CQ-25
50
40
12.5
25
3.5
3.0
50CQ-32
50
40
12.5
32
3.5
4
65CQ-32
65
50
25
32
4.0
7.5

VIStructural diagram of CQ engineering plastic magnetic pump
7、 CQ EngineeringPlastic magnetic pumpInstallation and use:
1. Magnetic pumps should be installed horizontally and not vertically. The plastic pump body should not bear the weight of the pipeline. For special requirements for vertical installation, the motor must face upwards.
2. When the suction liquid level is higher than the pump axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve.
3. Before using the pump, it should be checked that the motor fan blades rotate flexibly, without jamming or abnormal noise, and all fasteners should be tightened.
4. Check if the rotation direction of the motor is consistent with the direction mark of the magnetic pump.
5. After the motor starts, slowly open the discharge valve and adjust it to the desired opening after the pump enters normal operation.
6. Before the pump stops working, the discharge valve should be closed first, and then the suction pipe valve should be closed.
8、 CQ EngineeringPlastic magnetic pumpPrecautions for use:
1. Due to the fact that the cooling and lubrication of magnetic pump bearings rely on the medium being transported, it is absolutely forbidden to operate them in idle mode, while also avoiding the possibility of spatiotemporal rotation caused by power outages and restarts during operation.
2. If the conveyed medium contains solid particles, a filter screen should be added to the pump inlet; if it contains ferromagnetic particles, a magnetic filter should be added.
3. The ambient temperature of the pump during use should be less than 40 ℃, and the temperature rise of the motor should not exceed 75 ℃.
4. The conveyed medium and its temperature should be within the allowable range of the pump material (see attached table for details). The operating temperature of engineering plastic pumps is less than 60 ℃, the operating temperature of metal pumps is less than 100 ℃, the conveying suction pressure is not greater than 0.2Mpa, the maximum working pressure is 1.6Mpa, the density is not greater than 1600kg/m3, and the particle size is not greater than 30 × 10-6m2/S, which is a liquid without hard particles and fibers.
5. For media that are prone to precipitation and crystallization during transportation, they should be cleaned promptly after use to drain the accumulated liquid in the pump.
6. After 100 hours of operation of the magnetic pump, the wear of the bearings and end face moving rings should be disassembled and inspected, and vulnerable parts that are no longer suitable for use should be replaced.
7. The magnetic couplings inside and outside this series of pumps are made of high-performance permanent magnet materials, which may pose potential hazards to the following components. Please keep the following components at a distance from this series of pumps. Such as pacemakers, credit cards and other magnetic cards, calculators, computer disks, watches, etc.

CQ EngineeringPlastic magnetic pumpFaults and troubleshooting methods

failure mode
cause
Troubleshooting
The pump is not producing water
1. Reverse rotation of water pump
2. Leakage at the beginning of the inlet pipe
3. Insufficient water storage in the pump chamber
4. The voltage is too high, causing the coupling to slip during startup
5. The suction distance is too high
Change the motor wiring
Eliminate air leakage
Increase storage capacity
Adjust the positive voltage
Installation position of Longlow pump
Insufficient traffic
1. The suction pipe diameter is too small
2. Impeller channel blockage
3. Head too high
4. The speed is too low
Replace the inlet pipe
Clean the impeller
Turn up the outlet valve
Restore rated speed
Low head
1. Excessive traffic
2. The speed is too low
Turn down the outlet valve
Restore rated speed
too much noise
1. Severe wear of the shaft
2. Severe wear of the shaft sleeve
3. Drive the magnetic steel cup to contact the isolation sleeve
Replace the pump shaft
Replace the shaft sleeve
Dismantle the pump head and reassemble it
Leakage of liquid
O-ring damaged
Replace the O-ring seal