Which is a good intelligent high-frequency noise simulator

NegotiableUpdate on 01/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Japanese NOISEKEN 2KV high-frequency noise simulator NS-S220 meets the Japanese JIS industrial standard, with a high voltage of 2kV and a bandwidth of up to 1 μ s. The new model uses semiconductor relays to improve the stability of the test pulse waveform and adds options for various tests.

Product Details

NOISEKEN 2KV High Frequency Noise Simulator from JapanINS-S220

Meets Japanese JIS industrial standards, with a high voltage of 2kV and a bandwidth of up to 1 μ s. The new model uses semiconductor relays to improve the stability of the test pulse waveform, enabling better quantitative and reproducible testing than before; Add options for various tests.

NOISEKEN 2KV High Frequency Noise Simulator from JapanINS-S220Product Features:

  • Can achieve high-speed pulse cycle switching testing: because the frequency of pulse switching is very fast, the occurrence rate of misoperation will also increase, and it can be expected that the testing time will be shortened;

  • The setting of pulse width is very simple: simply press the button to set in 50ns steps, which shortens the setting time and reduces the occurrence of wiring errors;

  • The stability of the test pulse waveform is better, and it can achieve highly reproducible testing;

  • Reduced the quantity of consumables and effectively lowered usage costs;

  • By using a short-circuit plug, it is very easy to switch between common mode/differential mode testing;

  • The instrument is equipped with a 50 Ω terminal, which is easy to wire;

  • Through the output panel, the EUT's AC plug can be directly connected; (Optional)

  • Simulators can conduct various experiments through various probes, coupling clips, adapters, etc; (Optional)

  • By adding a coupling network, experiments on EUT power supply three-phase 5-wire can be conducted; (Optional)

Specifications:

project

Specifications

Pulse setting range ①

Pulse output voltage

0.5kV~0.99kV ± 10% 0.01k step

pulse width

100ms~1000ns±10%

repetition cycle

1ms~999ms ± 10% 1ms step

Pulse setting range ②

Pulse output voltage

1.00kV~2.00kV ± 10% 0.01kV step

pulse width

50ns~1000ns ± 10% 50ns step

repetition cycle

10ms~999ms ± 10% 1ms step

output voltage

0.5-2kV ± 10% (10V step)

polarity

Positive/Negative

rise time

Below 3ns

output impedance

50Ω

Terminal impedance

50Ω

repetition cycle

Line phase

50Hz/60Hz injection phase angle 0-360 °± 10 ° (1 ° step) superimposed with L-N synchronous output

duration

1ms to 999ms ± 10% (pulse setting range ①)

10ms to 999ms ± 10% (pulse setting range ②)


external trigger

Selection period: 10ms or more Pulse width: 1ms or more Input level: TTL/Open circuit rectifier negative logic

If LINE PHARE mode is selected and the input period is 16-20ms, it will be recognized as the synchronization signal of CDN


1 SHOT

Press the 1SHOT key once to output once

Synchronize the phase angle output with the phase angle output in PHARE mode


Memory capacity

5 experiments

Test time

1-999s ± 10% 1-second step

Overlay phase switching

L (+), N (-), PE/PULSE OUT ※ Manually switch with coaxial line

Blending Mode

Common mode/differential mode ※ Manual switching with short circuiting plug

Power capacity of the tested equipment (EUT)

单相 AC240V/DC125V 16A(L(+),N(-),PE)

power supply

AC100~240V 50Hz/60Hz

Temperature/humidity range for use

15~35℃ 25~75℃

Size

(W) 430 × (H) 249 × (D) 540mm (excluding protrusions)/approximately 20kg

High voltage coaxial joint

NMHV Noiseken

attachment

Coaxial line 30cm (02-00013A): 2 pieces, SG short-circuit plug (02-00106A): 1 piece, SG connection wire (05-00103A): 1 piece, output panel: 1 piece, AC power cord: 1 piece, operation manual: 1 volume, accessory package: 1 piece

Attachment:

name

model

quantity

description

coaxial cable

02-00013A

2 pieces

Set line for pulse output, 30cm

SG sets short-circuit plug

02-00106A

1 piece

NMHV NOISEKEN specification plug

SG connection line

05-00103A

1 piece

Grounding connection wire

Output panel

1 piece

NMHV NOISEKEN specification panel, installed

power cord

1 piece

Single phase terminal lifting type AC240V/DC60V 16AMax

Operation Manual

1 volume

attachment package

1 piece

High frequency noise simulatorRecommended configuration:

High frequency testing standards

Model Configuration

description

Japanese JIS Industrial Standards

INS-S220

High frequency noise simulator;

EFTD

Pulse group experimental table;

Other testing options:

Non standard options

IJ-4050

Three phase coupling network: AC415V 50A

18-00084A

Output panel; Provide plugs for plugging in

00-00017A

Attenuator for waveform observation; DC~2GHz:40dB

00-00011A

Attenuator; 20dB • N-type connector

15-00014A

Coupling clip; Capacitive coupling, wire diameter 20mm, high input voltage: 4000V

CA-805B

Coupling clip (capacitive coupling); Device for testing signal lines

CA-806

Coupling clip; Magnetic field coupling, wire diameter 27mm, high input voltage: 2000V

H2-B

EMS probe kit; Accessories for radiation testing

INS-S220选件