The purpose of the Youwei Environmental Protection Pipeline UV Disinfector is that UV is a type of light wave that is invisible to the naked eye and exists on the outer side of the spectral UV ray end, hence it is called UV. The ultraviolet system comes from one of the electromagnetic waves emitted by the sun, and is a special form of material movement, consisting of a stream of unconnected particles. Each ultraviolet photon with a wavelength of 253.7nm has an energy of 4.9eV.
Purpose of Uwei Environmental Protection Pipeline UV Disinfector
UV irradiation intensity sensor/UV irradiation intensity monitor: The UV irradiation intensity sensor can monitor the output intensity of the UV disinfection system in real-time online, and output mixed signals of 0-5V or 4-20mA for use by the monitor. The ultraviolet irradiation intensity monitoring device receives signals from sensors and can set the alarm value of irradiation intensity and the service life of the lamp tube according to requirements. Real time monitoring of the system to ensure the normal operation of equipment.
Sleeve cleaning system: It has a selectable manual or fully automatic cleaning system. Each type can be cleaned online without stopping the machine. Quartz casing will scale if it comes into contact with water for a long time, and it must be effectively cleaned. This product has a simple cleaning ring structure and is not prone to aging. The flexible cleaning components of the cleaning ring can actively adapt to quartz sleeves, ensuring cleaning effectiveness even if there are deviations in sleeve installation without wearing down the quartz sleeves.
Purpose of Uwei Environmental Protection Pipeline UV Disinfectormaintain:
1) Dismantling of quartz tube: First, turn off the power, open the protective covers on both sides of the sterilizer, remove the lamp tube, remove the end caps, take out the "O" ring inside the water seal seat, and then slowly remove the quartz tube.
2) Assembly of quartz tube: Operators should not directly touch the surface of the quartz tube with their hands to avoid dirtying and affecting transparency. Align the quartz tube with the water seal holes at both ends, insert the quartz tube with equal clearance at both ends, insert the "O" - shaped rubber ring, slowly and evenly tighten the pressure cover, and do not apply too much force to prevent the quartz tube from breaking. Then conduct a water test. If there is water leakage, gently tighten the pressure cover until there is no water leakage, and then install the lamp tube for operation.