The pH electrode uses a linear glass film with a measurement range of 0-14 pH. It also adopts a structure that inhibits the outflow of silver chloride from the liquid junction of the comparative electrode. It can measure continuously and stably under various measurement conditions such as high temperature, dilute solution, and reducing solution.

Product Details

DKK-TOA industrial process control pH and ORP analyzer and transmitter can be obtained from Gengsheng, providing multiple options and configurations to adapt to various applications.

Each process monitoring environment has * requirements, including electrode sensor configuration, battery type and configuration, system pressure and cleaning requirements.

In addition to the main controller, Gengsheng also provides automatic sensor cleaning equipment, including water jet, ultrasonic, chemical and physical sensor cleaning devices

lKCl Supply typepH electrode

pHThe electrode adopts a glass film with linearity *, and the measurement range can reach0~14pHAnd adopt a structure that suppresses the outflow of silver chloride from the liquid junction of the comparative electrode. canContinuous and stable measurement under various measurement conditions such as high temperature, dilute solution, and reducing solution.

Fluorine resistant glass film can be used in solutions containing fluoric acid; In addition, there are electrodes that are resistant to organic solvents, and the reference electrode sealing material is made of Perfluororo material, which has * drug resistance. Moreover, the temperature compensation resistor (TC: 10K Ω) adopts a protruding structure, which improves the response of temperature compensation.

model

Internal liquid injection

Entry method

window film

category

pH

Measurement range

Temperature range for use

reference electrode

sealing material

Lead wire material

Immersion sheath

representative model

5600-F

No pressure applied

Standard film

0~14pH

-570

FPM(fluororubber)

heat-resistantPVC

HC-763

5601-F

-595

FPM

silicon

HC-703F

5602-F

-570

Perfluororubber

heat-resistantPVC

HC-703T

5603-F

-595

Perfluororubber

silicon

HC-703T

5605-F

Fluorine resistant film

2~11pH

-550

FPM

heat-resistantPVC

HC-703C

5610-F

Pressurized type

Standard film

0~14pH

-570

FPM

heat-resistantPVC

HC-753

5611-F

-595

FPM

silicon

HC-753F

5612-F

-570

Perfluororubber

heat-resistantPVC

HC-753T

5613-F

-595

Perfluororubber

silicon

HC-753T

5615-F

Fluorine resistant film

2~11pH

-550

FPM

heat-resistantPVC

HC-753C

Electrode lead length(5: 5m , 10: 10m)

lKCl Supply typeORP electrode

ORPThe sensing part of the electrode is made of platinum(Pt), or alloys primarily made of gold(M)Platinum electrodes are used for general purposesORPProcess control, alloy electrodes are used for wastewater, sewage, urine and feces treatment processes.

Built in temperature sensor(T)Automatically perform temperature compensation during temperature measurement and standard solution calibration. reference electrode(R)andpHThe reference electrode structure is the same, and the reference solution is3M(KCl)Solution.

model

constitute

Reference liquid

注入方式

Temperature range for use

reference electrode

sealing material

Lead wire material

sheath

Model representative

2600-F

Pt+R+T

pressure-free

-570

FKM

heat-resistantPVC

HC-763

2601-F

Pt+R+T

pressure-free

-595

FKM

silicon

HC-703F

2602-F

Pt+R+T

pressure-free

-570

Perfluororubber

heat-resistantPVC

HC-703T

2605-F

M+R+T

pressure-free

-570

FKM

heat-resistantPVC

HC-763

2610-F

Pt+R+T

Pressurized type

-570

FKM

heat-resistantPVC

HC-753

2615-F

M+R+T

Pressurized type

-570

FKM

heat-resistantPVC

HC-753

Electrode lead length(5: 5m , 10: 10m)