Welcome Customer !

Membership

Help

Shanghai Tianpu Analytical Instrument Co., Ltd
Custom manufacturer

Main Products:

plast-mach>Products
Product Categories

Shanghai Tianpu Analytical Instrument Co., Ltd

  • E-mail

    shtianpu@163.com

  • Phone

    13701654867

  • Address

    Room 2303, No. 3, Lane 51, Longcao Road, Xuhui District, Shanghai

Contact Now

Quotation for liquid chromatography instrument

NegotiableUpdate on 04/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The LC8000 high-performance liquid chromatograph has high precision, stability, and efficiency. A static motor control circuit designed with independent technology is used to achieve automatic feedback and tracking of motor control signals.
Product Details

LC8000 High Performance Liquid Chromatography SystemIt has the advantages of high precision, high stability, and high efficiency. The experience and techniques gained from the widespread use of LC-8000 HPLC in various fields of analytical chromatography have been applied to the development of new technologies, continuously enriching the various functions required for experiments.

Instrument features:

The static motor control circuit designed using independent technology achieves automatic feedback and tracking of motor control signals, effectively improving motor control accuracy and ensuring the reliability and stability of the pump.

Pump form: series or parallel double plunger;

Floating self correcting sealing ring technology and pump head self-cleaning function technology can extend the service life of the sealing ring, ensuring the durability and high efficiency of the instrument;

Convenient and easy-to-use flow and pressure calibration functions ensure high precision and stability of the instrument;

Using two gradient running program designs: linear gradient and step gradient are optional;

Programmable solvents and compression factors that can be automatically compensated;

Complete pre cleaning function, facilitating quick solvent replacement;

Adopting holographic dual grating technology;

Using high-precision photodiode design to expand linear range;

Convenient and fast self correction function for light intensity gain coefficient;

Holmium glass cell design, full wavelength scanning, convenient wavelength correction;

Universal sample cell design, easy to replace between trace and constant cells;

Deuterium lamps are easy and fast to replace, and can be used without calibration.

LC8000 High Performance Liquid Chromatography SystemTechnical Specifications:

High pressure Shuye pump

flow range

0.001-10ml/min (set step size 0.001mL/min)

traffic volume

≤±0.25%(0.001-10mL/min)

work pressure

42.0MPa with adjustable upper and lower limits, automatic alarm

Display pressure error

<±0.5MPa(0~42MPa)

pressure pulsation

<0.1MPa

Sealing performance of the pump

The pressure is 42MPa, the time is 10 minutes, and the pressure drop is less than 0.5MPa

Flow precision

RSD<0.05%<>

gradient

2 yuan or 3 yuan

Gradient method

The gradient elution internal software can be self controlled and controlled through a PC and pump

power supply

AC110V/220V,50Hz/60Hz

Overall dimensions

400mm×300mm×180mm

UV detector

light source

Deuterium lamp/tungsten lamp

optical path design

Monochromator with dual channel silicon photodiode detector

linear range

2.8AU(5%)

wavelength range

190-700nm increments of 1nm

wavelength repeatability

0.2nm

Wave length

±1nm

Band width

<6nm<>

Absorption range

0.000U/mV-4AU/mV

Data system output

4AU/V injection signal control, automatic zeroing, supports dual output of integrator and recorder

baseline noise

≤± 0.25 × 10-U (empty pool, response time 1 second, 20 ℃)

≤2×10-U(甲醇,1ml/min,254nm,20℃)

baseline drift

≤ 0.4 × 10-4AU/hr (empty pool, response time 1 second, 20 ℃)

≤2×10-4/hr(甲醇,1ml/min,254nm,20℃)

Small detection concentration

4 × 10-9g/mL (methanol solution of naphthalene)

sample pool

Analysis cell (10mm optical path, 10.0ul volume)

power supply

AC110V/220V,50Hz/60Hz

size

400mm×300mm×180mm

Excitation wavelength range

190~900nm

Emission wavelength range

190~900nm

Detector response range

190~900nm (photomultiplier tube), 300~800nm (single photon counter)

spectral bandwidth

激发5 nm/10nm/15nm/20nm, 发射5 nm/10nm/15nm/20nm

Wave length

±1nm

Wavelength property

±0.2nm

monochromator

1200 line holographic grating

Shuye pump

flow range

0.001-10ml/min

degree

±1%

precision

0.25%

pressure range

0-42MPa

gradient

2 yuan

Gradient method

The gradient elution internal software can be self controlled and controlled through a PC and pump

power supply

100to240VAC,50to60Hz,80watts

size

40CM(L)×30CM(W)×18CM(H)

weight

8.0kg

detector

light source

Deuterium lamp/tungsten lamp

optical path design

Monochromator with dual channel silicon photodiode detector

wavelength range

190-700nm increments by 1nm, can be set by keyboard or RS232/485/USB

bandwidth

<6m<>

Wavelength accuracy

±1nm

wavelength repeatability

0.2nm

Absorption range

0.000U/mV-4AU/mV

Data system output

4AU/V injection signal control, automatic zeroing, supports dual output of integrator and recorder

noise

±0.5x10-U

drift

2x10-4AU(P-P)

sample pool

Standard conical pool (10mm optical path, 4.5ul volume), semi prepared (5mm optical path, 3.5ul volume)

power supply

100to240VAC,50to60Hz,80watts

size

40CM(L)×30CM(W)×18CM(H)

weight

8.0kg