Welcome Customer !

Membership

Help

Shenzhen Chenyi Technology Co., Ltd
Custom manufacturer

Main Products:

plast-mach>Products
Product Categories

Shenzhen Chenyi Technology Co., Ltd

  • E-mail

    noiseken@vip.163.com

  • Phone

    18138274970

  • Address

    5A033, Unit 1, B2 Office Building, Gaobei Sixteen, No.16 Gaoxin North Sixth Road, Songpingshan Community, Xili Street, Nanshan District, Shenzhen

Contact Now

Quotation for fast transient pulse group simulator for power supply

NegotiableUpdate on 01/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The FNS-AX4-B63 electric fast transient pulse group simulator meets the IEC61000-4-4Ed.3 standard, with a high voltage of up to 5000V and a high frequency of up to 2MHz. It can be connected to a computer to use software and achieve automated testing. Adding options can also evaluate and test the anti-interference performance of signal lines and substrates.

Product Details

Electric Fast Transient Pulse Group SimulatorFNS-AX4-B63

Meets the IEC61000-4-4Ed.3 standard, with a voltage of up to 5000V and a frequency of up to 2MHz. It can be connected to a computer to use software and achieve automated testing. Add options and evaluate the anti-interference performance of signal lines and substrates through testing

Electric Fast Transient Pulse Group SimulatorFNS-AX4-B63Product features:

  • The simulator program has a self checking function, which makes the test results more reliable;

  • By using optional components, differential modeling tests can be conducted to simulate the interference sources that actually cause faults; (Optional)

  • The use of three color indicator lights at the beginning of the test ensures safer testing; (Optional)

  • EUT plugs can be connected to corresponding socket box sockets; (Optional)

  • The new simulator has a smaller size and is easy to transport;

  • A simple and clear panel can reduce errors when connecting EUT;

  • The operation screen of the LCD panel has a clearer operating experience, and the multi language function in the program can meet the needs of different languages;

  • You can use control software corresponding to AndroidTM (tablet) and Windows (computer) to operate the simulator; (Optional)

  • The software has multiple functions such as "correction date notification" and "help"; (Only available on Android/Windows software)

  • The output voltage of the simulator can reach 5kV, and the pulse frequency can reach 2MHz, which can perform tests far beyond the standard test level.

  • CDN capacity has reached single ▪ The three-phase model AC600V/63A can meet higher EUT power capacity requirements.

  • Use high-capacity CDN (100A or 150A) to meet higher testing requirements of EUT; (Optional)

  • The anti-interference tolerance of signal lines and substrates can be evaluated and tested using coupling clips and EMS probe kits. (Optional)

generatorSpecifications:

project

Specification and Function

output voltage

200~5000V 10V step

polarity

Positive or negative, pulse group polarity can be continuously reversed

pulse frequency

0.1kHz ~ 2000kHz

0.1kHz~1kHz/0.01kHz Step accuracy ± 5%

1.0kHz~10kHz/0.1kHz step accuracy ± 5%

10kHz~100kHz/1kHz Step accuracy ± 5%

100kHz~1000kHz/10kHz Step accuracy ± 5%

1000kHz~2000kHz/100kHz Step accuracy ± 10%

When the pulse is continuously output, there is a limit to the voltage

pulse count

1~1000/1 step

Set limit: Within 1 pulse group, 1 pulse/ms (pulse frequency above 1kHz)

Pulse group time

Calculation method: (number of pulses)/(pulse frequency)

The adjustable range of pulse group time for direct setting: 0.01~999ms

pulse train period

10~1000ms ± 10% 10ms step (500ms for polarity reversal)

Polarity reversal function

Each pulse group cycle has a positive/negative polarity, alternating between outputs

Setting conditions: The pulse group period is more than 500ms, and the pulse group rest time [(pulse group period) - (pulse group time)] is more than 100ms.

Maximum test time: 10 minutes

Pulse continuous output

0 ~ 1000V 10kHz 以下

0 ~ 2000V 4kHz 以下

0 ~ 5000V 1kHz 以下

The maximum test time for all experiments is 10 minutes

frequency modulation

Continuous frequency transition from the set frequency to approximately -10%. A triangular wave with a modulation frequency of approximately 20Hz

external trigger

When an external input signal is received, the simulator is synchronously triggered to output one pulse train. The input specification for the trigger signal is Hi (+5V) → Lo (0V), and one pulse train is output

pulse waveform

At 50 Ω load

Pulse peak voltage: (set voltage/2) ± 10%

Rise time: 5ns ± 30%

Pulse width: 50ns ± 30%

pulse waveform

At 1K Ω load

Pulse peak voltage: (set voltage x 0.95) ± 20%

Rise time: 5ns ± 30%

Pulse width: 35~150ns

DC blocking inductor

10nF ±20%

CDNSpecifications:

project

Specification and Function

power capacity

Three phase AC600V/63A, DC125V/63A (but N/PE is 10A)

Shi Jiaxiang

L1/L2/L3/N/PE can be single-phase, full phase, or each phase separately

coupling mode

Common mode usage options allow for differential mode coupling

Input/output mode

6mm safety socket

coupling capacitor

33nF

Output waveform specifications

Pulse peak voltage: (set voltage)/2 ± 10%

Rise time: 5.5 ns ± 1.5 ns

Pulse width: 45 ns ± 15 ns

(Set voltage ± 4000V; indicators for frequency 5kHz~100kHz)

Input residual voltage

Set the pulse voltage to below 10%

(Indicator when EUT power cord input is 50 Ω terminal and power cord output is open circuit)

AC power line synchronization

Can be set synchronously or asynchronously

Set phase angle: 0~360 °± 10 ° 1 ° step

Voltage can be set during synchronization: from AC85V to rated voltage, phase as reference: between L1-N2

Other specifications:

project

Specification and Function

Emergency stop

Press switch (test stop, EUT power cord OFF)

EUT FAIL function

An external FAIL signal (Hi → Lo) was detected during the experiment

FAIL signal specifications VLO: 0V, VHI:+5V

When the FALL signal action is detected, the test can be temporarily stopped

FAIL input is 3 channels

external interface

REMOTE: Fiber optic communication interface, connected when controlled by an external PC

CDN I/F: CDN control interface, connected when using an external CDN

INDICATOR: Connect warning lights and display lights for use

EUT FAIL INPUT: Temporarily tested for use in case of EUT malfunction

(External CDN and warning lights are optional)

working environment

Temperature range of 15~35 ℃

Relative humidity 25~75%

External dimensions/weight

W430 × H199 × D370mm (excluding protrusions)/approximately 22 kg

drive power supply

AC100~240V ± 10% 50/60Hz, approximately 120VA

Attachment:

name

Specification

Operation Manual

1 set

Factory Verification Report

1 copy

power cord

1 piece

SG cable

1 piece

Corresponding standards and configurations:

Electrical Fast Transient Pulse Group Testing Standard

Model Configuration

description

IEC61000-4-4 Ed.3

FNS-AX4-B63

Test host;

ESDD

Pulse group test environment;

15-00012A

Coupling clip; Device for testing signal lines (optional)

00-00017A

Attenuator for waveform observation; Matching impedance 50 Ω, 40dB

00-00018A

Attenuator for waveform observation; Matching impedance 1000 Ω, 60dB

<strong><strong>电快速瞬变脉冲群模拟器</strong></strong>


辰仪科技