-
E-mail
674338455@qq.com
-
Phone
18611900152
-
Address
Institute of Physics, Chinese Academy of Sciences, Zhongguancun, Haidian District, Beijing
Beijing Beidouxing Technology Co., Ltd
674338455@qq.com
18611900152
Institute of Physics, Chinese Academy of Sciences, Zhongguancun, Haidian District, Beijing
Portable gas calorific value analyzerpGas2000-CGprincipleThe gas sensor adopts infrared photometer and electrochemical testing principle
Application of Calorimeter: Analysis of natural gas, gas field or * gas, petroleum gas, and condensate gas field; The main components of liquefied petroleum gas are propane, butane, etc; Analysis of the main components of coal gas; Analysis of the main components of coal mine gas; Combustible ice detection.

Portable gas calorific value analyzerInstrument Features:
According to the actual situation of the user, the analysis of CO, H2, CH, CO2, H2S, H2O gas content can be achieved on one instrument
Equipped with convenient backpack, printing and reading functions, it is particularly convenient for on-site testing or laboratory testing of on-site sampling
Calorimeter function:
Directly sampling with a learning probe
All keyboard settings are available for operation, and the window prompts that a serial micro printer can be included
On site LCD 4 × 20 character rotating display of multiple environmental parameters
Support calorific value calculation
Quickly detect parameters and temperature values, and perform temperature correction and cross correction
Inert gas software zeroing, standard sample or substitute calibration
Technical parameters of portable gas calorific value detector:
Resolution: 0.025% FS
Repetition accuracy: 0.05% FS
Response time:<1min; >
Long term stability: ± 10%/year (general)
Power supply: 12V rechargeable battery
Operating environment temperature: -10 ℃~60 ℃; Humidity: 10%~90% R (no condensation)
Storage environment temperature: 0 ℃~50 ℃; Humidity: 10%~80% R (no condensation)
Standard sampling conditions: temperature: 0~40 ℃; Pressure: 0.9~1.1 kgf/cm2
Portable gas calorific value tester pGas2000 CG
Detection parameters:
gas |
range |
repeatability accuracy |
accuracy |
carbon monoxide CO |
0~20% |
±0.1%FS |
<±1%fs<> |
20~99% |
<5%r<> |
||
Hydrogen H2 |
0~8% |
<1%r<> |
<2%r<> |
Hydrocarbons HC |
0~99% |
<±0.1%abs<> |
<±0.25%abs<> |
Carbon dioxide CO2 |
0~25% |
<±0.1%abs<> |
<±0.25%abs<> |
Oxygen O2 |
0~30% |
<±0.1%abs<> |
<±0.2%abs<> |
Hydrogen sulfide H2S |
0~1000ppm |
<±1%r<> |
<±2%r<> |
H2O |
100ppm~3% |
||
calorific value |
0~40MJ/NM3 Refer to user situation |
PGas2000 CG Calorimeter
Common Gas Composition Table:
Composition% |
blast furnace gas |
coke oven gas |
Generator gas |
Converter gas |
natural gas |
methane |
23~27 |
3~6 |
~100 |
||
Carbon hydrogen compound |
2-4 (unsaturated hydrocarbons above C2) |
≤0.5 |
|||
carbon monoxide |
27~30 |
5~8 |
26~31 |
60~80 |
|
hydrogen |
1.5~1.8 |
55~60 |
9~10 |
||
nitrogen |
55~57 |
3~8 |
55 |
||
carbon dioxide |
8~12 |
1.5~3 |
1.5~3.0 |
15~20 |
|
oxygen |
0.3~0.8 |
||||
|
Calorific value (kcal/Nm3) Heavy (kg/Nm3) Ignition point (℃) main properties |
850~950 1.295 700 colorless and odorless toxic flammable and explosive |
3900~4400 0.45~0.55 600~650 Colorless Odorous and toxic flammable and explosive |
1400~1700 1.08~1.25 700 Colored, odorous, and toxic flammable and explosive |
1800~2200 650~700 Colorless, odorless, toxic flammable and explosive |
8500~90000 0.7~0.8 550 Colorless with garlic odor Suffocating anesthesia Extremely flammable and explosive |
Beijing Beidouxing Industrial Chemistry Research Institute
Beijing Beidouxing Technology Co., Ltd