1、 Product Usage:
EXHFKLT2-II rope switch and emergency stop switch are switch type sensors (i.e. contactless travel switches) that have the characteristics of travel switches and micro switches, as well as sensing performance. They have reliable action, stable performance, frequency response, long service life, strong anti dry ability, waterproof, shockproof, corrosion-resistant and other characteristics. Widely used in various industries such as conveyor machinery, mining, textile, papermaking, printing, chemical, metallurgical, light industry, valves, power, security, railway, aerospace, etc.
The use of stainless steel double bearing transmission structure avoids direct friction between the transmission shaft and the housing or shaft sleeve during switch operation, resulting in increased clearance, poor sealing or jamming, greatly extending the service life of the rope switch; The surface of the shell is finely baked with paint, which is not easy to peel off and has no odor; The transmission shaft is made of stainless steel material with high strength and smooth surface; The operating rod is precision cast to avoid welding, with a built-in copper lining and overall smooth and strong finish. This switch has the characteristics of long service life, flexibility and practicality, safety and reliability, and easy maintenance. When the maintenance personnel have not evacuated or there are other abnormal situations, as long as the rope switch is locked in the stop position, there is no need to worry about the tape machine being mistakenly started.
EXHFKLT2-II Explosion proof Bidirectional Rope Switch
2、 Product Description:
The rope (wire) switch is bi-directional and can be installed in the middle position of the conveyor or at both ends
The universal installation design allows the cable switch to be installed on both sides of the conveyor longitudinal beam, as well as on the top of the conveyor longitudinal beam
Durable cast aluminum casing, with special surface treatment options for the environment
The integral cover plate makes wiring and switch adjustment convenient and simple, without the need to disassemble the switch
Compact design of structural components
Prominent black arm initial support with yellow or silver shell, easy to distinguish between alarm or normal status
Provide complete accessories, including wire ropes, rope clamps, and cable support bolts
Manual lever reset
Used for Class II areas, with the addition of isolation covers, it can be used for Class I areas
Optional red flag for alarm indication

3、 Application scope:
Conventional belt conveyor
Shuttle conveyor
Skirt type feeding conveyor
bucket elevator
packaging line
Stacking/retrieval system, crane, excavator
Ship loading and unloading system
Horizontal feeder
4、 Installation instructions:
1. The rope switches are installed in pairs on the left and right sides of the belt conveyor. Drill a 12mm hole in the corner iron frame next to the belt conveyor and tighten the rope switches with M10 × 40mm bolts.
2. Install one rope switch every 40 meters, and its position should be on the belt and convenient for on-site use.
3. The pull rope is tied to a closed arm, and a plastic coated steel wire rope with a diameter of 3-5mm can be used for the pull rope. The steel wire rope is fixed with rope clamps, and a support ring is installed every 3 meters or so to prevent excessive sagging of the steel wire rope and ensure reliable pulling action. On the premise of meeting the normal operation of the switch, tighten the rope as much as possible to reduce the deflection of the steel wire rope.
4. For the climbing section belt conveyor, the distance between the rope switches and the length of the rope should be shortened as much as possible.
5. Wiring: The pull rope switch is equipped with a 1.2-meter-long four core rubber sheathed cable when it leaves the factory. The core wire is equipped with wire numbers 1, 2, 3, and 4, where 1 and 2 are normally open contacts for alarm signals, and 3 and 4 are normally closed contacts for shutdown signals. EXHFKLT2-I,HFKLT2-I,HFKLT2-I,KLT2-II,KLT2-I