1、 Product Introduction
JC-OIL-6Infrared oil analyzer, water oil analyzer, new national standard HJ637-2018Using tetrachloroethylene andcarbon tetrachlorideExtract oil substances from the sampleDetermine the total oil content, then adsorb the extract with magnesium silicate to remove polar substances such as animal and vegetable oils, and determine the petroleum content.
The content of total oil and petroleum is calculated based on the absorbance A2930, A2960, and A3030 at spectral bands with wave numbers of 2930cm-1 (C-H bond in CH2 group), 2960cm-1 (stretching vibration of C-H bond in CH3 group), and 3030cm-1 (stretching vibration of C-H bond in aromatic ring), respectively. The content of animal and vegetable oils is calculated based on the difference between the total extract and petroleum content.
This instrument is suitable for the determination of petroleum and animal and plant oils in groundwater, surface water, industrial wastewater, and domestic sewage.
2、 Product parameters
| 1 | Method detection limit: | When the sample volume is 1000ml and the extraction solution volume is 25ml, the detection limit is 0.01mg/L |
| 2 | Instrument detection limit: | DL ≤ 0.04mg/L (3 times SD of 11 measurements of carbon tetrachloride blank solution) |
| 3 | Wave number accuracy: | ± 0.5cm-1. Using automatic positioning calibration, oil samples above 30mg/L are automatically calibrated at 2930cm-1, 2960cm-1, and 3030cm-1, eliminating the influence of human positioning |
| 4 | Repeatability: | The RSD of the 30-40mg/L oil standard sample measured 11 times is ≤ 0.6% or the RSD of the 0.5mg/L water sample is ≤ 5%. The instrument's optical and electrical systems are self-contained and highly integrated, thereby improving the reliability and repeatability of the instrument |
| 5 | Accuracy error: | ≤1% |
| 6 |
correction factor Accuracy: |
Using carbon tetrachloride as a reference solution and a 4cm colorimetric dish, measure 2mg/L, 5mg/L, 20mg/L, 50mg/L, and 100mg/L petroleum standard solutions with an error of ± 10% |
| 7 | Scanning speed: | Full spectrum scanning, 30 seconds/time; Non dispersive infrared method for 2 seconds |
| 8 |
basic Measurement range: |
0.0~800mg/L |
| 9 |
Zui Low Detected concentration: |
0.0008mg/L (water sample concentration) |
| 10 |
zuibig Measurement concentration: |
99.99%oil |
| 11 | Linear correlation coefficient | Linear correlation coefficient r>0.999 |
| 12 | Wave number range: | 3400cm-1~2400cm-1(即2941nm~4167nm) |
| 13 | Absorption range: | 0.0000-3.0000 AU (i.e. transmittance of 100-1% T) |
| 14 | temperature | 10-55℃ |
| 15 | relative humidity | 5%-95% |
| 16 |
host Power Supply: |
(220±22)V、(50±1)Hz、50VA |
| 17 | Shell material | Integrated engineering plastic structure (PC+ABS), anti electromagnetic radiation treatment, impact resistance, anti-corrosion |
3、 Product Features
1Infrared oil analyzer, water oil analyzer, new national standard HJ637-2018,Select a 10.8-inch Windows 8 tablet, embedded in the host instrument, the tablet can be flexibly removed, and the host reserves an external computer communication control interface.
2. Multiple usage modes: tablet embedded in host instrument, tablet removed from host instrument, external PC, these three usage modes do not affect the overall layout of the instrument host, and the system realizes touch control compatible with wireless keyboard and mouse control.
3. Equipped with self checking and result judgment functions: it will prompt if the energy is abnormal, and at the same time, it will prompt possible causes for reference in troubleshooting; Capable of generating instrument self checking energy information log recording function; Equipped with software to determine whether the sample exceeds the standard prompt function.
4. Communication method: Bluetooth USB、 Serial port.
5. Cloud database: The instrument is equipped with a cloud database that stores the self checking status information of the instrument and the content of each test (operator, time, test results, sample name, etc.).
6. The instrument uploads cloud data using GPRS, NB-IOT, and WIFI.
7. Baseline stability: Real time automatic adjustment of zero point (eliminating the influence of baseline drift), the computer collects both the signal when the light source emits light and the signal when the light source goes off, achieving real-time automatic adjustment of zero point, simplifying operation and improving long-term signal stability.
8. Software system: Adopting dual system analysis to meet the use of carbon tetrachloride or tetrachloroethylene as extractants.
9. Calibration method: The instrument can be calibrated using both standard curves and coefficients, with multiple calibration methods to meet different environmental requirements.
10. Light source system: The lifespan of the light source can reach over 50000 hours. The light source uses electrical modulation to regulate the light source technology, preventing the internal temperature of the instrument from affecting stability.
4、 Product selection
1. Confirm the usage location and environment first
① Laboratory bench: JC-OIL-8, JC-OIL-6, JC-OIL-6A
② Field test: JC-OIL-6B
③ On site real-time monitoring: JC-OIL-6Z online water quality analyzer
2. Confirm the configuration you need
JC-OIL-6 instrument+Windows tablet+single jet extractor can replace manual extraction.(Recommended type)
There are other configurations to choose from, such as triple extractors, etc.