E-mail
qdjchb@foxmail.com
-
Phone
13127012891
-
Address
15th Floor, Building 3, No. 266 Jiushui East Road, Licang District, Qingdao City, Shandong Province
Qingdao Juchuang Environmental Protection Group Co., Ltd
qdjchb@foxmail.com
13127012891
15th Floor, Building 3, No. 266 Jiushui East Road, Licang District, Qingdao City, Shandong Province
Automatic infrared oil analyzer
1、 Product Introduction
Juchuang JC-OIL-6DPlus typeAutomatic infrared oil analyzerIt consists of a fully automated operating software system, an infrared spectroscopy system, and a pre-processing extraction system. Fully automated, without the need for operators to come into contact with tetrachloroethylene, including automatic sampling, extraction, water and impurity removal, measurement, cleaning, drainage, and data storage.
The machine adopts drum type three-dimensional mixing technology to extract oil from water, remove water and impurities, and then measure it in a colorimetric dish. The built-in magnesium silicate adsorption device can measure the content of petroleum and animal and vegetable oils. After the measurement is completed, the instrument will automatically discharge and clean the waste.
Instrument application scope:
Environmental monitoring systems are used in testing rooms and laboratories for petrochemical, hydrological and water conservancy, water supply companies, sewage treatment plants, thermal power plants, steel enterprises, scientific research and teaching in universities, agricultural environmental monitoring, railway environmental monitoring, automobile manufacturing, marine environmental monitoring, transportation environmental monitoring, environmental research, etc.
2、 Product parameters
project |
Technical Specifications |
Water sample measurement range |
Measurement range: 0-100000mg/L, (dilution or enrichment extraction) |
Instrument detection limit |
0.03mg/L |
Method Detection Limit |
0.002mg/L |
repetitiveness |
RSD ≤ 1% (tested 11 times for 20-100mg/L oil standard sample) |
Measurement accuracy |
Error<± 1> |
resolution |
0.001mg/L |
correlation coefficient |
R>0.9995 |
Volume of water sample taken |
5ml-600ml or 5ml-1000ml |
Sample size for testing |
Continuous testing of 10 samples (standard), optional with other digit injectors |
Extraction amount of tetrachloroethylene |
Integer multiples of 10-25ml |
measure time |
5-10 minutes |
Wavenumber range |
2930、2960、3030cm-1 |
Range of absorbance |
0.0000-2.0000 AU (i.e. transmittance of 100-1% T) |
Wave number accuracy and wave number repeatability |
±0.5cm-1 |
Use power supply |
(220±22)V、(50±1)Hz、50VA |
Use temperature and humidity |
Temperature range 1 ℃ -40 ℃, humidity ≤ 90% |
external dimensions |
750mm (length) x 420mm (width) x 420mm (height) |
3、 Product Features
1. Fully automated: Fully automated sampling, extraction, water filtration, measurement, drainage, cleaning, can continuously produce 10 water samples.
2. Health and safety: The entire operation does not require the participation of analysts and does not come into contact with tetrachloroethylene, ensuring the health and safety of operators.
3. High precision automatic injector: reagent 0-50ml can be set arbitrarily, automatic dilution for excessive concentration, automatic preparation of quality control samples and standards, and automatic one click calibration.
4. Compliant with the national standard HJ637-2018, the true three wavenumber and infrared three wavenumber spectra are clear and accurately calibrated, displaying the absorption spectra and absorbance generated by the three wavenumbers clearly.
5. Core oil-water separation technology: equipped with imported anti clogging oil-water separation membrane, with an effective filtration area of over 45mm, dual membrane separation filtration, replacingAnhydrous sulfur sodiumOne film can be used about a hundred times.
6. The manufacturer is equipped with an infrared standard oil filter, which can be used for a long timePerform single point calibration, lifetime replacement free for one standard curve, and no need to prepare standard oil reagents.
7. The instrument is equipped withTetrachloride*The dual extraction mode of tetrachloroethylene can use tetrachloroethylene instead of tetrachloride as the extractant.
8. It can perform fully automatic detection of total oil, petroleum or animal and vegetable oils, automatically display the remaining amount of magnesium silicate or automatically fill and replace magnesium silicate.
9. Baseline stability: Zero point automatic real-time adjustment (eliminating the impact of baseline drift).
10. Built in 11 inch multi touch computer control terminal, with a small size that can be placed in a standard fume hood.
11. One click completion: Multiple water sample tests can be completed with just one click upon startup, without the need for other operations, reducing the workload of operators.
12. One click calibration: automatic detection and calibration of blank and standard oil, 2-8 multi-point calibration, and single point calibration are all automatically completed.
13. The built-in computer adopts the Windows 10 operating system and USB 2.0 interface technology, and can also be connected to an external desktop computer.
14. Adopting efficient high-speed and fast drum three-dimensional positive and negative magnetic stirring extraction, 8-12 water samples are extracted simultaneously, fully sealed, non-volatile and non-toxic.
15. Stable 4.0 green installation free, automatic wavelength positioning, UV infrared dual system one click switching oil analyzer software, semi-automatic and fully automatic operation one click switching.
16. The sampling bottle is an extraction bottle with a scale display. It can be directly extracted on the machine without dividing the sample. The method complies with HJT91-2002, and the extraction results are consistent with the national standard method.
17. Automatic fault detection: The pre-processing system for automatic detection upon startup has *, and the automatic detection host has *, which is convenient for users to maintain and operate. It can also upgrade the mobile app function.
18. Manual and automatic dual operation modes, which can measure samples automatically or manually.
19. The automatic sampling system is an integrated system for simultaneous extraction of water samples, achieving precise positioning of water sample cups. Independent pipelines are configured for reagent addition, sample extraction, and waste liquid discharge, and multiple samples can be extracted simultaneously without interference, improving work efficiency.
20. The entire extraction system adopts large-diameter pipeline materials that are acid and alkali resistant, tetrachloroethylene or carbon tetrachloride resistant, fully corrosion-resistant, non oleophilic, emulsifying and anti blocking, reducing cross contamination and minimizing interference with emulsified water samples.
21. Automatic separation of water and tetrachloroethylene waste liquid, automatic collection of waste liquid such as tetrachloroethylene reagents, and discharge of wastewater.