1.
analysis scope:0~100%
2.
analysis time:
●
Ordinary crude oil: ≤ 1 hour
●
Hot recovery emulsified heavy oil: ≤ 3 hours
3.
analysis error:±1%
4.
Measuring cylinder volumeUsually 800ml, but there are also other specifications such as 280ml
5.
heating power:≤150W
6.
Dehydration power consumption:≤15W
7.
power supply:AC 220V±10%,50Hz
Dehydration steps
Pour the processed oil sample into a dehydration glass graduated cylinder, then insert the "heating dehydration internal electrode" into the dehydration glass graduated cylinder oil sample, turn on the "dehydration" and "heating" switches, and the heating and dehydration indicator lights will turn on, indicating that heating and dehydration are in progress. Slowly stir the oil sample with an internal electrode to facilitate uniform heating and rapid dehydration. Heat to an appropriate temperature so as not to cause the oil sample to boil violently and overflow. If the temperature is too high, immediately turn off the heating switch. When the free water settling no longer increases, turn off the "heating" and "dehydration" switches, and then remove the heating inner electrode.
Here are several possible fault phenomena and inspection and maintenance methods that may occur during the use of the instrument, listed as follows:
serial number |
Fault phenomenon |
Inspection steps |
Repair and treatment |
1 |
The heating and dehydration indicator lights are not on, and the ammeter has no indication. |
① Check if the power cord plug and power socket are in good contact and have electricity; ② Check if the fuse is intact; ③ Check if there is voltage input to the primary of the transformer; ④ Check if there is voltage output from the secondary of the transformer. |
Replace the fuse, inspect all plugs and sockets, or replace the transformer. |
2 |
The heating indicator light is not on, and the internal electrode is not heating up. |
① Check if the heating plug socket is in good condition; ② Check if the heating wire is burnt out. |
Repair the heating plug socket or replace the internal electrode. |
3 |
The heating indicator light is not on, and the internal electrode is heating up. |
① Check if the heating switch indicator light has poor contact or is damaged. |
Repair or replace the heating switch. |
4 |
The dehydration indicator light is on, there is no high voltage output, and the ammeter has no indication. |
① Check if the rectifier diode is damaged; ② Check if the transistor is damaged; ③ Check the ammeter; ④ Check the high-voltage package. |
① Replace the diode; ② Replace the transistor; ③ Replace the ammeter; ④ Replace the high-voltage package |
5 |
Poor dehydration effect. |
① The inspection steps are the same4; ② Check if the high-voltage line is in good contact. |