1.Ankerui 20 channel temperature monitoring intelligent electrical deviceOverview
The ARCM300-T20 series multi circuit temperature measuring detector (hereinafter referred to as the detector) is designed for TT and TN systems below 0.4kVMonitor and manage fire hazard parameters such as wire temperature in distribution circuits to prevent electrical fires from occurring.
The product adopts excellent microcontroller technology, with high integration, compact size, easy installation, and integrates intelligence, digitization, and networking,It is an ideal choice for building electrical fire prevention monitoring, system insulation aging estimation, etc.
2.Ankerui 20 channel temperature monitoring intelligent electrical deviceModel Description

3. Technical Parameters

4. Buttons and operation instructions
Can monitor temperature and issue alarm commands based on the magnitude of the temperature. And when the input signal reaches the alarm setting, it emits a light alarm.

Indicator Light Instructions
run/Alarm lamp:
Status 1: The indicator light is green and keeps flashing, with a flashing frequency of approximately once per second; Indicates that the instrument is in normal operation.
State 2: The indicator light is red and constantly on; Indicates that the instrument is in an alarm state.
5. Precautions
Sensor matching and installation
The external sensor is a temperature sensor, which is a customized product and cannot be replaced with products from other manufacturers at will. The temperature probe should be tightly attached to the cable during installationInstall on the surface of the busbar or at cable joints, and tighten with nylon zip ties during installation. In addition, according to customer requirements, the temperature probe can also be suspended or tightly attachedCabinet installation, used to measure the temperature of the environment or cabinet.
The setting of the electrical fire monitoring system should not affect the normal operation of the power supply system and should not automatically cut off the power supply.
After installation, technical personnel should set parameters that meet the actual requirements on site, and conduct operational experiments to ensure the normal operation of the detectorthat 's ok.