The HCP8000 series current clamp, a favored current probe series among engineers, is a high-frequency current probe that can measure both DC and AC simultaneously. It has a three-year warranty period, which is superior to warranty services in the same industry. Engineers often use it as a replacement for high-frequency current probe series such as Tektronix, Sidon, Lico, and Yokogawa. The key is its high cost-effectiveness. If you want to save money and use practical current probes, you can make a free appointment for our engineers to come and demonstrate. If you are satisfied with our product, you can decide whether to purchase it.Our products will make you feel at ease when buying and using them!

-HCP8000 Series Current Clamp with Zhiyong Probe
This product is lightweight and can be easily used in crowded circuit boards; Small clamps can detect current in tight spaces while still being able to clamp wires with a diameter of up to 5mm; It can provide a bandwidth of 50MHz, and the probe has two ranges to choose from: 30A (10X) and 5A (1X). The 5A (1X) range is particularly suitable for small current measurement, with a resolution of up to 1mA. It can measure continuous current of 30A and peak current of 50A. The CP8000 series current probe is commonly used in the design and testing applications of switch power sources, motor drivers, electronic rectifiers, LED lighting, new energy, etc.
1Oscilloscope current probe 150AProduct Features:
1. High bandwidth, capable of accurately and quickly capturing current waveforms;
2. High precision, with an accuracy of up to 1% within the current measurement range, meeting the needs of most testing fields;
3. Two measurement ranges are available for selection, making it convenient for small current measurements;
4. Automatic demagnetization and zero adjustment function, easy to use;
5. Sound and light overcurrent alarm function, reminding range switching;
6. Electronic touch sensitive button design for longer lifespan;
7. Standard BNC output interface, compatible with any manufacturer's oscilloscope.
IIOscilloscope current probe 150AApplication:
1. Power supply (switch and linear) design
2. Lighting design
3. Electric vehicle design
4. New energy
5. Variable frequency household appliances
6. Electrical Experiment
7. Semiconductor Device Design
8. Inverter/Transformer Design
9. Electronic ballast design
10. Industrial control/consumer electronics design
11. Design of engine drive system
12. Power electronics and power transmission experiments, etc
13. Design of transportation systems (electric vehicles, locomotives, aviation electronic equipment, etc.)
3、 Product electrical specifications:
| model | HCP8030 |
HCP8030D |
HCP8050 | HCP8150 | HCP8300 | HCP8500 | ||||
| Bandwidth (-3dB) | HCP8030 | DC-50MHz | DC-50MHz | DC-12MHz | DC-6MHz | DC-5MHz | ||||
| HCP8030D | DC-100MHz | |||||||||
| rise time | HCP8030 | ≤7ns | ≤7ns | ≤29ns | ≤58ns | ≤70ns | ||||
| HCP8030D | ≤3.5ns | |||||||||
| Continuous current value | HCP8030 | 30Arms | 50Arms | 150Arms | 300Arms | 500Arms | ||||
| HCP8030D | 30Arms | |||||||||
| peak current | 50Apk | 75Apk | 300Apk | 500Apk | 750Apk | |||||
| range | 5A | 1X attenuation | 7.5A | 1X attenuation | 30A | 10X attenuation | 50A | 10X attenuation | 75A | 10X attenuation |
| 30A | 10X attenuation | 50A | 10X attenuation | 150A | 100X attenuation | 300A | 100X attenuation | 500A | 100X attenuation | |
| Overcurrent alarm value | 5A | ≥5A | 7.5A | ≥7.5A | 30A | ≥30A | 50A | ≥50A | 75A | ≥75A |
| 30A | ≥50A | 50A | ≥75A | 150A | ≥300A | 300A | ≥500A | 500A | ≥750A | |
| Current transmission ratio | 5A | 1V/A | 7.5A | 1V/A | 30A | 0.1V/A | 50A | 0.1V/A | 75A | 0.1V/A |
| 30A | 0.1V/A | 50A | 0.1V/A | 150A | 0.01V/A | 300A | 0.01V/A | 500A | 0.01V/A | |
| resolution | 5A | 1mA | 7.5A | 1mA | 30A | 5mA | 50A | 5mA | 75A | 5mA |
| 30A | 10mA | 50A | 10mA | 150A | 50mA | 300A | 50mA | 500A | 50mA | |
| Accuracy (DC, 45-66Hz, continuous current) | 5A | ±1%±1mA | 7.5A | ±1%±1mA | 30A | ±1%±10mA | 50A | ±1%±10mA | 75A | ±1%±10mA |
| 30A | ±1%±10mA | 50A | ±1%±10mA | 150A | ±1%±100mA | 300A | ±1%±100mA | 500A | ±1%±100mA | |
4、 Principle of current probe:
The current flowing through the wire will cause the formation of an electromagnetic flux field around the wire. The current probe is designed to sense the field strength of this magnetic flux field and convert it into the corresponding voltage for measurement using an oscilloscope. This allows the use of an oscilloscope to view and analyze current waveforms. When combined with the voltage measurement function of an oscilloscope, the current probe also allows for various power measurements. According to the waveform mathematical operation function of the oscilloscope, these measurements can include instantaneous power, real power, apparent power, and phase.
The current probes of oscilloscopes are basically divided into two categories: AC current probes and AC/DC current probes. AC current probes are usually passive probes, while AC/DC current probes are usually active probes. Both types use the same conversion principle, which is to sense the current in the wire.
To perform conversion, a current must first flow through the wire, and a magnetic flux field must be constructed and eliminated based on the amplitude and direction of the current flow. When a coil is placed in this field, the changing magnetic flux field will induce voltage in the coil through a simple conversion operation. This conversion operation is the basis of AC current probes.
5、 Other products:
The SNA5000X series Vector Network Analyzer has a measurement frequency of up to 8.5GHz and supports 4-port S-parameter measurement, differential (balanced) measurement, time-domain measurement, filter insertion loss, bandwidth, Q value and other one click measurements. It also supports port impedance conversion, port expansion function, limit testing, ripple testing function, fixture simulation and de embedding function, linear frequency scanning, logarithmic frequency scanning, segmented frequency scanning, linear power scanning mode, SOLT, SOLR, TRL, Response, Enhanced Response and other calibration methods. It can be widely used in the research and development, production and manufacturing of filters, duplexers, antennas, active devices, RF cables and other fields.