E-mail
821614517@qq.com
-
Phone
19124373227
-
Address
301, Building B, HI Space, No. 3 Fufu Road, Yongping Street, Baiyun District, Guangzhou City
Guangzhou Noda Electronics Co., Ltd
821614517@qq.com
19124373227
301, Building B, HI Space, No. 3 Fufu Road, Yongping Street, Baiyun District, Guangzhou City
gas detection |
Fluorine gas F2 |
quantity Cheng |
/0-100PPM/0-50PPM/0-20PPM (More ranges can be consulted); |
divide distinguish rate |
0.01PPM |
Detection Principle |
electrochemistry |
essence degree |
≤±3F. S |
display mode |
320 * 240 high-definition color screen |
response time |
T90<30S |
recovery time |
≤30S(T90-T10) |
service life |
Sensor 2-3 years |
Detection method |
diffusion |
heavy again sex |
≤±1 %F.S |
succeed electricity device |
Capacity 220VAC 3A/24VDC 3A |
|
Wireless output Optional |
433M (≤ 3 kilometers accessible)(定制) GPRS (unlimited distance)(定制) WIFI/zigbee/LORA(定制) |
Wired output Optional |
485+switch outputStandard configuration 4-20mA+RS485+Switch alarm output (定制) Choose one of the above options |
Protection level |
IP66 |
Explosion-proof rating |
Explosion proof type: Exd Ⅱ CT6 Gb |
ruler inch |
205*140*92mm(L×W×H) |
Probe material |
Aluminum alloy, stainless steel (optional) |
Installation method |
Wall mounted, pole mounted, pipeline mounted |
heavy quantity |
1KG |
Working Voltage |
12-35VDC, Commonly used 12VDC, 24VDC |
electrical interface |
Wiring port size: internal thread M20*1.5( G1/2 Internal thread G3/4 internal thread, 1/2NPT |
Standard Accessories |
Detector, manual, infrared remote control, manufacturer's factory inspection report |
select match document |
Explosion proof sound and light alarm, installation bracket, pipeline installation accessories, etc |
working environment |
Temperature: Catalytic combustion: -40~+70 ℃; Electrochemistry: -20~+50 ℃; PID:-20~+50℃; Infrared: -20~+50 ℃; Fluorescence method:-20~+50℃;Zirconia: -40 ℃~+700℃ Pressure: 86-110KpaZirconia: ≤0.6Mpa) Humidity: 15% RH~95% RH (no condensation) |
||
Product power consumption |
Electrochemical sensor: P ≤ 1.2W Infrared sensor: P ≤2.0W Conventional catalytic sensor :P ≤ 2.6W Low power catalytic sensor :P ≤ 1.5W Thermal conductivity sensor :P ≤2.0W |
||
|
execution standard |
GB15311.1-2003; GB3836.1-2010; GB3836.2-2010; GB3836.4-2010; |
||
Feature Overview
★Fast Core System: Equipped with a 32-bit high-speed microprocessor and an Epson data processing system, it can quickly detect hazardous gases and warn of toxic gas leaks;
★ Multi level calibration: Industry intelligent multi-level calibration technology, multiple filtering technology, more accurate and faster feedback of on-site concentration values;
★ Alarm system: sound and light alarm;
★ Stability: After strict feeding screening process and the ingenuity of R&D personnel with more than ten years of industry experience, it is resistant to EMC and EMI interference;
★ Multi structure communication method: Supports 4-20mA and RS485 single or multiple simultaneous communication, wired and built-in wireless 433M/GPRS wireless multi-channel communication (optional);
★ Standard specifications: JJF 1363-2012, JJF 1368-2012, JJF 1421-2013, JJF 1364-2012; GB3836-2010,GB 12476.5-2013;
Introduction to Fluorine Gas F2 Gas
Fluorine gas is a light yellow, highly toxic gas. Highly corrosive and chemically active, it is a highly oxidizing elemental substance that can even react with some inert gases under certain conditions. It is a highly toxic gas that can irritate the eyes, skin, and respiratory mucosa. Due to its immediate reaction with water to produce hydrogen fluoride, it exhibits the same toxicity as hydrogen fluoride in most cases.