1 Overview
DTSD1352-4S seriesRail type multi circuit power meterMainly used for full electrical parameter measurement of multiple circuits, it can simultaneously connect up to 4 three-phase circuits or 12 single-phase circuits for current input. It can measure parameters such as voltage, current, power factor, phase angle, imbalance, harmonics, etc.
2 Product functions and technical parameters
2.1 Product Features
The specific functions are as follows:
Measurement of full electrical parameters for 4-channel three-phase or 12 channel single-phase circuits, with external current transformers;
Monitor the zero sequence current frequency of each phase voltage/current;
Monitor the total power of each phase (active and reactive power);
Monitor the power factor of each phase and the total power factor;
Monitor voltage/current phase angle and voltage/current imbalance;
Monitor the total harmonic and 2-31st harmonic of voltage and current;
Record the extreme values of voltage, current, and power for the current month and the previous month;
● Current power demand and real-time current real-time power demand;
200 event records, recording the action status of DIDO;
● Support alarm outputs such as overvoltage, overcurrent, phase loss, DI linkage, etc;
● Rate setting for 4 time zones and 14 time periods;
Four quadrant electricity, 12-month compound rate electricity statistics;
31 day four quadrant and compound rate energy freeze, forward and reverse energy metering;
Four passive switch inputs, two active switch inputs, and one switch output for RS485 communication;
● Two passive switch input and two switch output RS485 communication;
Note: Four passive switch inputs, two active switch inputs, one switch output, and two passive switch inputs and two switch outputs can only be selected as one.
2.2 Main technical parameters
Table 1 DTSD1352-4S Main Technical Parameters

2.3 Other technical parameters
Table 2 Other Technical Parameters

3 matching transformers
DTSD1352-4S seriesRail type multi circuit power metermatchingThe current transformer adopts a crystal head interface, with a primary side current of 100A-600A and a secondary side output current of 50mA. If the current transformers are different, customers can modify the current ratio through the instrument interface or communication according to actual usage. The transformer is shown in Figure 1 and Figure 2.

Table 3 DTSD1352-4S Supporting Current Transformer

Note: Special transformers can be consulted for specific information.
4 External dimensions (unit: mm)