Welcome Customer !

Membership

Help

Shanghai Zhongcheng Pump Manufacturing Co., Ltd
Custom manufacturer

Main Products:

plast-mach>Products

Shanghai Zhongcheng Pump Manufacturing Co., Ltd

  • E-mail

    info@cnspump.com

  • Phone

  • Address

    9F, No. 7, Lane 3088, Gonghe New Road (Xiangteng Fortune Plaza), Shanghai, China

Contact Now

D. DG type horizontal boiler feed centrifugal pump

NegotiableUpdate on 04/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The D-type horizontal, single suction multi-stage, segmented centrifugal pump products comply with the JB/T1051-93 "Types and Basic Parameters of Multi stage Clean Water Centrifugal Pumps" standard. It has the characteristics of high efficiency, wide performance range, safe and stable operation, low noise, long service life, and easy installation and maintenance. It is used to transport clean water or other liquids with physical and chemical properties similar to water. It can also be used to transport hot water, oil, corrosive or abrasive media by changing the material and sealing form of the pump flow components and adding cooling systems. Suitable for industrial and urban water supply and drainage, high-rise building pressurized water supply, garden sprinkler irrigation, fire pressurization, long-distance water supply, heating, bathroom and other cold and warm water circulation pressurization and equipment matching, especially suitable for small boiler water supply. Our multi-stage pumps are all designed and optimized using computers. The company has strong technical strength, rich production experience, and comprehensive testing methods to ensure stable and reliable product quality.
Product Details

Product Introduction


The D-type horizontal, single suction multi-stage, segmented centrifugal pump products comply with the JB/T1051-93 "Types and Basic Parameters of Multi stage Clean Water Centrifugal Pumps" standard. It has the characteristics of high efficiency, wide performance range, safe and stable operation, low noise, long service life, and easy installation and maintenance. It is used to transport clean water or other liquids with physical and chemical properties similar to water. It can also be used to transport hot water, oil, corrosive or abrasive media by changing the material and sealing form of the pump flow components and adding cooling systems. Suitable for industrial and urban water supply and drainage, high-rise building pressurized water supply, garden sprinkler irrigation, fire pressurization, long-distance water supply, heating, bathroom and other cold and warm water circulation pressurization and equipment matching, especially suitable for small boiler water supply. Our multi-stage pumps are all designed and optimized using computers. The company has strong technical strength, rich production experience, and comprehensive testing methods to ensure stable and reliable product quality.

Product features:

  1. The hydraulic model is advanced, efficient, and has a wide range of performance.
  2. The pump runs smoothly with low noise.
  3. The shaft seal adopts soft packing seal or mechanical seal, which is safe, reliable, structurally simple, and easy to maintain.
  4. The shaft is a fully enclosed structure, ensuring no contact with the medium, no corrosion, and a long service life.

Technical parameters: Flow rate: 6.3-300m3/h; Head: 13-650m; Power: 2.2-400KW; Speed: 1450-2950r/min; Caliber: 50-200; Temperature range: ≤ 105 ℃; Work pressure: ≤ 3.0Mpa.

Model Meaning


D(DG) 46 - 50×12

D - Segmented centrifugal pump for water supply


G - Boiler pump

46- Design flow rate (m3/h)50- Single stage head (m)


12- Level
Selection range Suitable for industrial and urban water supply and drainage, high-rise building pressurized water supply, garden sprinkler irrigation, fire pressurization, long-distance water supply, heating, bathroom and other cold and warm water circulation pressurization and equipment matching, especially suitable for small boiler water supply. performance parameter This data is for reference only, please refer to the actual order! Performance parameter table of D-type horizontal multi-stage centrifugal pump: Model
series internet traffic lift power rotational speed
m?/h 3 18 5 28.5 3 2950
4 38 4
5 47.5 5.5
6 57 5.5
7 66.5 7.5
8 76 7.5
9 85.5 7.5
10 95 11
11 104 11
12 114 11
L/S 2 32.4 9 22.7 3 2950
3 34.1 5.5
4 45.5 7.5
5 56.8 7.5
6 68.1 11
7 79.5 11
8 90.8 15
9 102.1 15
10 113.5 18.5
11 124.9 18.5
12 136.2 18.5
(mm) 2 43 12 60 15 2950
3 90 18.5
4 120 22
5 150 30
6 180 37
7 21 45
8 240 55
9 270 55
10 300 55
(Kw) 2 54 15 32 7.5 2950
3 48 15
4 64 18.5
5 80 22
6 96 22
7 112 30
8 128 30
9 144 37
10 160 45
11 176 55
12 132 55
(r/min) 2 108 30 40 18.5 2950
3 60 30
4 80 37
5 100 45
6 120 55
7 140 75
8 160 75
9 180 90
10 200 90
50D8
80D12 80D30 100D16 125D25 Performance parameter table of DG type horizontal multi-stage centrifugal pump: model series rotational speed
internet traffic lift power efficiency Required cavitation allowance rpm m3/h
m 3 2950 3.75 76.5 2.37 4 33 2
6.3 75 2.86 45 2
7.5 73.5 3.19 47 2.5
4 3.75 102 3.16 5.5 33 2
6.3 100 3.81 45 2
7.5 98 4.26 47 2.5
5 3.75 127.5 3.95 5.5 33 2
6.3 125 4.77 45 2
7.5 122.5 5.32 47 2.5
6 3.75 153 4.73 7.5 33 2
6.3 150 5.72 45 2
7.5 147 6.39 47 2.5
7 3.75 178.5 5.52 7.5 33 2
6.3 175 6.67 45 2
7.5 171.5 7.45 47 2.5
8 3.75 204 6.31 11 33 2
6.3 200 7.63 45 2
7.5 196 8.52 47 2.5
9 3.75 229.5 7.1 11 33 2
6.3 225 8.58 45 2
7.5 220.5 9.58 47 2.5
10 3.75 255 7.89 15 33 2
6.3 250 9.53 45 2
7.5 245 10.65 47 2.5
11 3.75 280.5 8.68 15 33 2
6.3 275 10.5 45 2
7.5 269.5 11.71 47 2.5
12 3.75 306 9.47 15 33 2
6.3 300 11.44 45 2
7.5 294 12.78 47 2.5
shaft power 3 2950 7.5 84.6 3.93 5.5 44 2
12.5 75 4.73 54 2
15 69 5.32 53 2.5
4 7.5 112.8 5.24 7.5 44 2
12.5 100 6.3 54 2
15 92 7.09 53 2.5
5 7.5 141 6.55 11 44 2
12.5 125 7.88 54 2
15 115 8.89 53 2.5
6 7.5 169.2 7.85 15 44 2
12.5 150 9.46 54 2
15 138 10.64 53 2.5
7 7.5 197.5 9.16 15 44 2
12.5 175 11 54 2
15 161 12.41 53 2.5
8 7.5 225.6 10.41 15 44 2
12.5 200 12.61 54 2
15 184 14.18 53 2.5
9 7.5 253.8 11.78 18.5 44 2
12.5 225 14.18 54 2
15 207 15.95 53 2.5
10 7.5 282 13.09 18.5 44 2
12.5 250 15.76 54 2
15 230 17.73 53 2.5
11 7.5 310.2 14.4 22 44 2
12.5 275 17.34 54 2
15 253 19.5 53 2.5
12 7.5 338.4 15.7 22 44 2
12.5 300 18.9 54 2
15 276 21.3 53 2.5
Motor Power 3 2950 7.5 162 8.8 18.5 37.8 2
12.5 150 10.6 48 2
15 139.5 11.9 48 2.5
4 7.5 216 11.7 22 37.8 2
12.5 200 14.1 48 2
15 186 15.9 48 2.5
5 7.5 270 14.6 30 37.8 2
12.5 250 17.7 48 2
15 232.5 19.8 48 2.5
6 7.5 324 17.6 30 37.8 2
12.5 300 21.3 48 2
15 279 23.7 48 2.5
7 7.5 378 20.4 37 37.8 2
12.5 350 24.8 48 2
15 325.5 27.7 48 2.5
8 7.5 432 23.3 37 37.8 2
12.5 400 28.4 48 2
15 372 31.7 48 2.5
9 7.5 468 26.3 45 37.8 2
12.5 450 31.9 48 2
15 418.5 35.7 48 2.5
10 7.5 540 29.2 45 37.8 2
12.5 500 35.5 48 2
15 465 39.6 48 2.5
11 7.5 594 32.1 55 37.8 2
12.5 550 39 48 2
15 511.5 43.5 48 2.5
12 7.5 648 35 75 37.8 2
12.5 600 42.6 48 2
15 558 47.8 48 2.5
(%) 3 2950 15 102 8.33 15 50 2.2
25 90 9.88 62 2.2
30 82.5 10.7 63 2.6
4 15 136 11.1 18.5 50 2.2
25 120 13.1 62 2.2
30 m 14.26 63 2.6
5 15 170 13.89 22 50 2.2
25 150 16.47 62 2.2
30 137.5 17.83 63 2.6
6 15 204 16.67 30 50 2.2
25 180 19.17 62 2.2
30 165 21.4 63 2.6
7 15 238 19.44 30 50 2.2
25 210 23.1 62 2.2
30 192.5 24.96 63 2.6
8 15 272 22.22 37 50 2.2
25 240 26.4 62 2.2
30 220 28.53 63 2.6
9 15 306 25 37 50 2.2
25 270 29.65 62 2.2
30 247.5 32.1 63 2.6
10 15 340 27.8 45 50 2.2
25 300 32.9 62 2.2
30 275 35.7 63 2.6
DG6-25 3 2950 15 154.5 15.78 22 40 2.5
25 150 18.91 54 2.8
30 144 20.64 57 3.2
4 15 206 21.04 30 40 2.5
25 200 25.22 54 2.8
30 192 27.5 57 3.2
5 15 257.5 26.2 37 40 2.5
25 250 31.52 54 2.8
30 240 34.4 57 3.2
6 15 309 31.56 45 40 2.5
25 300 37.82 54 2.8
30 288 41.28 57 3.2
7 15 380.5 38.86 55 40 2.5
25 350 44.1 54 2.8
30 336 48.16 57 3.2
8 15 412 42 75 40 2.5
25 400 50.45 54 2.8
30 384 55.04 57 3.2
9 15 463.5 47.33 75 40 2.5
25 450 56.74 54 2.8
30 432 61.92 57 3.2
10 15 515 52.59 75 40 2.5
25 500 63.04 54 2.8
30 480 68.8 57 3.2
11 15 566 57.8 90 40 2.5
25 550 69.3 54 2.8
30 528 75.68 57 3.2
12 15 618 63.11 110 40 2.5
25 600 75.65 54 2.8
30 576 82.56 57 3.2
DG12-25 3 2950 30 102 13.02 22 64 2.4
46 90 16.11 70 3
55 81 18.84 68 4.6
4 30 136 17.36 30 64 2.4
46 120 21.48 70 3
55 108 23.79 68 4.6
5 30 170 21.7 37 64 2.4
46 150 26.85 70 3
55 135 29.74 68 4.6
6 30 204 26.04 37 64 2.4
46 180 32.21 70 3
55 162 35.68 68 4.6
7 30 238 30.38 45 64 2.4
46 210 37.58 70 3
55 189 41.63 68 4.6
8 30 274 34.72 55 64 2.4
46 240 42.95 70 3
55 216 47.58 68 4.6
9 30 306 39.06 55 64 2.4
46 270 48.32 70 3
55 243 53.53 68 4.6
10 30 340 43.3 75 64 2.4
46 300 53.7 70 3
55 270 59.5 68 4.6
DG12-50 3 2950 30 166.5 25.19 37 54 2.5
46 150 29.83 63 2.8
55 138 32.3 64 3.2
4 30 222 33.59 45 54 2.5
46 200 39.77 63 2.8
55 184 43.06 64 3.2
5 30 277.5 41.98 55 54 2.5
46 250 49.71 63 2.8
55 230 53.85 64 3.2
6 30 333 50.38 75 54 2.5
46 300 59.65 63 2.8
55 276 64.59 64 3.2
7 30 388.5 58.78 90 54 2.5
46 350 69.6 63 2.8
55 322 75.36 64 3.2
8 30 440 67.18 90 54 2.5
46 400 79.54 63 2.8
55 368 86.12 64 3.2
9 30 499.5 75.57 110 54 2.5
46 450 89.48 63 2.8
55 414 96.89 64 3.2
10 30 555 83.97 132 54 2.5
46 500 99.42 63 2.8
55 460 107.66 64 3.2
11 30 610.5 92.37 132 54 2.5
46 550 109.36 63 2.8
55 506 118.42 64 3.2
12 30 666 100.8 132 54 2.5
46 600 119.3 63 2.8
55 552 129.2 64 3.2
DG25-30 2 2950 55 102 24.25 37 63 3.2
85 90 28.94 72 4.2
100 78 30.33 70 5.2
3 55 153 36.38 55 63 3.2
85 135 43.4 72 4.2
100 117 45.52 70 5.2
4 55 204 48.5 75 63 3.2
85 180 57.87 72 4.2
100 156 60.7 70 5.2
5 55 255 60.63 90 63 3.2
85 225 72.34 72 4.2
100 195 75.86 70 5.2
6 55 306 72.75 110 63 3.2
85 270 86.81 72 4.2
100 234 91.04 70 5.2
7 55 357 84.88 132 63 3.2
85 315 101.3 72 4.2
100 273 106.2 70 5.2
8 55 408 97 132 63 3.2
85 360 115.7 72 4.2
100 312 121.4 70 5.2
9 55 459 109.1 160 63 3.2
85 405 130.2 72 4.2
100 351 136.6 70 5.2
no 3 2950 55 222 57.3 90 58 3.3
85 201 68.4 68 4
100 183 73.3 68 4.4
4 55 296 76.4 110 58 3.3
85 268 91.2 68 4
100 244 97.7 68 4.4
5 55 370 95.6 132 58 3.3
85 335 114 68 4
100 305 122.2 68 4.4
6 55 444 114.7 160 58 3.3
85 402 136.9 68 4
100 366 146.6 68 4.4
7 55 518 133.8 200 58 3.3
85 469 159.6 68 4
100 427 171 68 4.4
8 55 592 152.9 220 58 3.3
85 536 182.4 68 4
100 488 195.4 68 4.4
9 55 666 172 250 58 3.3
85 603 205.2 68 DG25-50
100 549 219.9 68 4.4
DG46-30 3 2950 100 228 97 132 64 3.2
155 201 114.7 74 5
185 177 123.9 72 6.6
4 100 304 129.3 200 64 3.2
155 268 152.9 74 5
185 236 165.1 72 6.6
5 100 380 161.6 220 64 3.2
155 335 191.1 74 5
185 295 206.4 72 6.6
6 100 456 194 280 64 3.2
155 402 229.3 74 5
185 354 247.7 72 6.6
7 100 532 226.3 315 64 3.2
155 469 267.5 74 5
185 413 289 72 6.6
8 100 608 258.6 355 64 3.2
155 536 305.7 74 5
185 472 330.3 72 6.6
9 100 684 290.9 400 64 3.2
155 603 344 74 5
185 531 371.6 72 6.6
DG46-50 3 1480 185 141 103 160 69 3
280 129 127.7 77 4.7
335 114 138.7 75 6
4 185 188 137.3 200 69 3
280 172 170.3 77 4.7
335 152 184.9 75 6
5 185 235 171.6 250 69 3
280 215 212.9 77 4.7
335 190 231.1 75 6
6 185 282 205.9 315 69 3
280 258 255.5 77 4.7
335 228 277.3 75 6
7 185 329 240.2 355 69 3
280 301 298.1 77 4.7
335 266 323.6 75 6
8 185 376 274.5 400 69 3
280 344 340.7 77 4.7
335 304 369.8 75 6
9 185 423 308.9 450 69 3
280 387 383.2 77 4.7
335 342 416 75 6
DG85-45 5 2980 15 433 55 75 32 3.2
25 400 60.5 45 3.5
30 390 72.1 44 5
6 15 519.6 66 90 32 3.2
25 480 72.6 45 3.5
30 468 86.52 44 5
7 15 606.2 77 110 32 3.2
25 560 84.7 45 3.5
30 546 100.94 44 5
8 15 692.8 88 132 32 3.2
25 640 96.8 45 3.5
30 624 115.36 44 5
9 15 779.4 99 132 32 3.2
25 720 108.9 45 3.5
30 702 129.78 44 5
10 15 866 110 160 32 3.2
25 800 121 45 3.5
30 780 144.2 44 5
11 15 952.6 121 200 32 3.2
25 880 133.1 45 3.5
30 858 158.62 44 5
12 15 1039.2 132 200 32 3.2
25 960 145.2 45 3.5
30 936 173.04 44 5
DG85-67 7 2950 36 585.2 114.8 180 50 3.9
45 560 124.6 55 4
62 477.4 143.5 56 5.5
8 36 668.8 131.2 200 50 3.9
45 640 142.4 55 4
62 545.6 164 56 5.5
9 36 752.4 147.6 220 50 3.9
45 720 160.2 55 4
62 613.8 184.5 56 5.5
10 36 836 164 250 50 3.9
45 800 178 55 4
62 682 205 56 5.5
11 36 919.6 180.4 280 50 3.9
45 880 195.8 55 4
62 750.2 225.5 56 5.5
12 36 10032 196.8 280 50 3.9
45 960 213.6 55 4
62 818.4 246 56 5.5
4,0 7 2950 54 616 170.9 250 53 4.5
85 560 199.3 65 4.4
108 490 218.4 66 5.3
8 54 704 195.3 280 53 4.5
85 640 227.8 65 4.4
108 560 249.6 66 5.3
9 54 792 219.8 355 53 4.5
85 720 256.3 65 4.4
108 630 280.7 66 5.3
10 54 880 244.2 355 53 4.5
85 800 284.8 65 4.4
108 700 311.9 66 5.3
11 54 968 268.6 400 53 4.5
85 880 313.2 65 4.4
108 770 343 66 5.3
12 54 1056 293 450 53 4.5
85 960 341.7 65 4.4
108 840 374.3 66 5.3
DG155-67 6 2950 120 630 307 450 67 3.4
150 600 353 70 4.8
180 540 368 72 5.5
7 120 735 359 500 67 3.4
150 700 412 70 4.8
180 630 429 72 5.5
8 120 840 410 630 67 3.4
150 800 470 70 4.8
180 720 491 72 5.5
9 120 945 461 630 67 3.4
150 900 518 70 4.8
180 810 552 72 5.5
10 120 1050 512 800 67 3.4
150 1000 588 70 4.8
180 900 613 72 5.5
DG280-43 4 2950 250 420 386.4 450 74 5.1
280 400 396 77 5.6
300 392 416 77 5.9
5 250 525 483 630 74 5.1
280 500 495 77 5.6
300 490 520 77 5.9
6 250 630 579.6 710 74 5.1
280 600 594 77 5.6
300 588 624 77 5.9
7 250 735 676.2 800 74 5.1
280 700 693 77 5.6
300 686 728 77 5.9
8 250 840 772.8 1000 74 5.1
280 800 792 77 5.6
300 784 832 77 5.9
9 250 945 869.4 1120 74 5.1
280 900 891 77 5.6
300 882 936 77 5.9
10 250 1050 966 1250 74 5.1
280 1000 990 77 5.6
300 980 1040 77 5.9

DG25-80


DG45-80

DG85-80D、DG型卧式锅炉给水离心泵

DG150-100DG280-100


D、DG型卧式锅炉给水离心泵 D、DG型卧式锅炉给水离心泵

structural drawings

D、DG型卧式锅炉给水离心泵 D、DG型卧式锅炉给水离心泵

The D-type water pump is a multi-stage segmented type, with its suction port located on the inlet section in a horizontal direction, and its discharge port vertically upward on the outlet section. Its head can be increased or decreased according to the needs of use. Whether the water pump is well assembled or not has a significant impact on its performance, especially the outlet of each impeller and the inlet and outlet center of the guide vanes. Any slight deviation will reduce the flow rate and head of the water pump, resulting in poor efficiency. Therefore, attention must be paid to assembly after maintenance. The main components of a D-type water pump include: inlet section, middle section, outlet section, impeller, guide vane baffle, outlet section guide vane, shaft, sealing ring, flat flushing disc, shaft sleeve, tail cover, and bearing body. The inlet section, middle section, guide vane baffle, outlet guide wing, outlet section, and tail cover are all made of rust iron, forming the working chamber of the pump together. The impeller is made of high-quality rust iron and has blades inside. The liquid enters on one side along the axial direction. Due to the unequal pressure on the front and back of the impeller, there must be axial force, which is borne by the flat punch plate. The impeller is manufactured through static balance testing. The shaft is made of high-quality carbon steel, with an impeller installed in the middle, fixed on the shaft with keys, shaft sleeves, and shaft sleeve nuts. One end of the shaft is equipped with a coupling component, which is directly connected to the motor. The sealing ring is made of rust iron to prevent high-pressure water from leaking back into the inlet section of the water pump. It is fixed on the inlet and middle sections respectively and is a vulnerable part. After wear, it can be replaced with spare parts. The balance ring is made of cast iron and fixed on the outlet section. It, together with the balance plate, forms a flat flushing device. The balance plate is made of wear-resistant rust iron and is installed on the shaft, located between the water outlet section and the tail cover, to balance axial forces. The shaft sleeve is made of rust iron and is located at the packing chamber. It is used to fix the impeller and protect the pump shaft. It is a vulnerable part and can be replaced with spare parts after wear. The bearing is a single row radial ball bearing lubricated with calcium based grease. The packing plays a sealing role, preventing air from entering and a large amount of liquid from leaking out. The packing seal consists of a packing chamber on the inlet section and tail cover, a packing gland, a packing ring, and packing, etc. A small amount of high-pressure water flows into the packing chamber to act as a water seal. The tightness of the filler must be appropriate, neither too tight nor too loose, based on the ability of the liquid to seep out drop by drop. If the packing is too tight, the shaft sleeve is prone to heating and consumes power. The packing is too loose, which reduces the efficiency of the water pump due to liquid loss.


Structural diagram of D-type pump series horizontal multi-stage centrifugal pump:
  1. Installation size
  2. This data is for reference only, please refer to the actual order!
  3. Installation dimension diagram of D-type pump series horizontal multi-stage centrifugal pump:
  4. precautions
  5. Loading, unloading, starting, running, and stopping
  6. (1) Connection sequence:
  7. Tightly install the sealing rings on the inlet section and guide vane baffle respectively.
  8. Install the guide wing on the middle section, and then install the guide wing baffle on all the middle sections.
  9. Insert the installed shaft sleeve A and suspected shaft through the water inlet section, and push them into the impeller. Place a layer of paper pad on the middle section, install the middle section, and then push in the second impeller. Repeat the above steps to install all impellers and the middle section.
  10. Install the balance ring, balance sleeve, and outlet guide wing onto the water section separately.
  11. Install the water outlet section on the middle section, and then tighten the water inlet section, middle section, and water outlet section together with tightening bolts.
Install the flat punch plate and shaft sleeve B (not included in the 50DB pump).
  1. Install the paper pad onto the tail cover, install the tail cover onto the outlet section, and sequentially install the packing, packing ring, and packing cover into the packing chambers of the inlet section and tail cover.
    1. Install the bearing bodies separately onto the inlet section and the tail cover, and tighten them with bolts.
    2. Install the bearing positioning sleeve, ball bearing, and secure with nuts.
    3. Add an appropriate amount of butter into the bearing body, and cover the bearing cover with a paper pad. Install the bearing cover onto the bearing body and tighten it with screws.
  2. Install the coupling components, air release cock, and all square screw plugs. Disassemble according to the opposite steps.
    1. (2) Installation:
    2. Preparation work before installation.
    3. Check the water pump and motor.
    4. Prepare tools and lifting machinery.
    5. The foundation of the inspection machine.
    6. Installation sequence:
    7. The entire water pump has been transported to the site, and the electric motor has been installed with the base. It is not necessary to remove the water pump and motor when looking for a flat base.
Place the base on the foundation, place wedge-shaped shims near the anchor screws, and raise the base by about 20 degrees? 40mm, ready to level and fill with water grout.
  1. Use a spirit level to check the levelness of the base, level it, tighten the foot nuts, and fill the base with cement slurry.
  2. Through 3? After 4 days of cement solidification, check the water level again.
  3. Clean the dirt on the support plane of the base, the water pump foot, and the motor foot plane; , and place the water pump and motor on the base.
  4. Adjust the level of the pump shaft, tighten the nut appropriately after leveling to prevent movement. After the adjustment is completed, install the motor. Place an iron plate at the non level position, and leave a certain gap between the pump and the coupling.
  5. Place a ruler on the coupling and check if the axis of the water pump coincides with the axis of the motor. If not, place a thin sheet under the feet of the motor or pump to make the outer circles of the two couplings level with the ruler. Then take out several thin iron sheets from the pad and replace them with a whole iron plate that has been planed, and recheck the installation. In order to check the installation accuracy, use a feeler gauge at several opposite positions to measure the gap between the two coupling planes. The maximum and minimum gap difference on the coupling plane should not exceed 0.3 millimeters, and the difference between the center lines of both ends should not exceed 0.1 millimeters.
  6. (3) Start and Stop:
  7. Apply all the oil applied to the shaft and other oiled parts.
  8. Clean the bearings and oil chamber with gasoline, and wipe them clean with cotton yarn.
  9. Add calcium based spring oil into the bearing body.
  10. The experiment was successful. Check if the motor direction is correct and prevent the nut from loosening due to the rotation of the water pump. Then start the motor.
Inject water into the pump or empty the pump to draw water.
  1. Close the valve and pressure gauge plug on the discharge pipe.
  2. After the above process is completed, start the motor and open the pressure gauge plug
  3. When the water pump is running at normal speed, the pressure gauge displays the appropriate pressure, then open the vacuum gauge and gradually open the gate valve on the drainage pipeline until the required pressure is reached.
  4. When stopping the water pump, slowly close the gate valve on the drainage pipeline Close the vacuum gauge plug And stop the motor Then close the pressure gauge plug.

When the water pump is stopped for a long time The water pump should be disassembled Wipe off the water from the pump components And apply rust proof oil on the sliding surface for proper storage.


(4) Operation Pay attention to the temperature of the water pump bearings It shall not exceed the external temperature of 351, and its maximum temperature shall not exceed 751. The normal water leakage rate in the grave material room is not more than 15 milliliters per minute, and the tightness of the packing cover should be adjusted at any time.
Regularly inspect the shaft and pay attention to the temperature rise of the motor bearings. If there is any rattling or abnormal sound during operation, the vehicle should be stopped immediately to investigate the cause Troubleshooting
Fault reason solution
1. The water pump does not absorb water, and the pointers of the pressure gauge and vacuum gauge jump violently. The water injected into the pump is not enough, and there is air leakage in the pipes and instruments. Inject water into the water pump again Tighten and block the leak.
2. The water pump does not absorb water, and the vacuum gauge indicates high vacuum. The bottom valve is not open or has been blocked. The resistance of the suction pipe is too high. The water absorption height is too high. Correct or modify the bottom valve condition or change the suction pipe to reduce the suction height.
3. The pressure gauge has pressure, but the water pump still does not produce water. The resistance of the outlet pipe is too high, the rotation direction is incorrect, the impeller is blocked, and the water pump speed is not enough. Inspect or shorten water pipes and inspect motors. Remove the water pipe joint and clean the impeller. Increase the rotational speed of the water pump shaft.
4. The traffic is lower than the design requirements. The water pump is blocked, the sealing ring is worn too much, and the speed is insufficient. Clean the water pump and pipes, replace the sealing ring, and increase the speed of the water pump shaft.
5. The power consumption of the water pump is too high. The packing gland is too tight, the heating impeller of the packing box is worn, and the water supply of the pump increases. Loosen the packing cap. Replace the impeller and increase the resistance of the outlet pipe to reduce the flow rate.
6. The internal sound of the water pump is abnormal, and the water pump does not fill water. The flow rate is too high, and the resistance inside the suction pipe is too high. There is air infiltration at the water absorption point. The temperature of the liquid being sucked is too high. Increase the resistance inside the outlet pipe to reduce the flow rate. Inspect the suction pipe of the pump. Check the bottom valve, reduce the suction height, block the leakage area, and lower the suction height.