Welcome Customer !

Membership

Help

Shenzhen Simpson Refrigeration Technology Co., Ltd
Custom manufacturer

Main Products:

plast-mach>Products

Shenzhen Simpson Refrigeration Technology Co., Ltd

  • E-mail

    Simpsan@163.com

  • Phone

    189-2749-0225

  • Address

    Simpson Industrial Park, Maoyuan Industrial Zone, Huanguan South Road, Longhua District, Shenzhen

Contact Now

Binary stacked ultra-low temperature refrigeration unit

NegotiableUpdate on 04/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The binary cascade ultra-low temperature refrigeration unit is the third generation cascade ultra-low temperature unit designed and developed by our company based on years of design and development experience combined with various actual measured operating parameters. It has the characteristics of stable performance, high efficiency, and high self-control, and can provide ultra-low temperature liquid cooling source from -135 ℃ to -40 ℃.
Product Details
The binary cascade ultra-low temperature refrigeration unit is the third generation cascade ultra-low temperature unit designed and developed by our company based on years of design and development experience combined with various actual measured operating parameters. It has the characteristics of stable performance, high efficiency, and high self-control, and can provide ultra-low temperature liquid cooling source from -135 ℃ to -40 ℃.
Product characteristics of binary stacked ultra-low temperature refrigeration unit
1. Using Bitzer imported compressors from Germany as the main engine, the main components are all internationally renowned brands. Combined with Siemsn industrial grade PLC and microcomputer control system from Germany, the system is safe and reliable, with a fully automatic control system and unmanned automatic alarm information function.
2. The binary stacked double ultra-low temperature refrigeration unit system is more optimized and stable, and can meet the demand for process cold sources in 24-hour continuous production in industrial production.
3. We can provide ultra-low temperature liquid cooling sources ranging from -135 ℃ to -40 ℃.

Two Cascade Low Temperature Chiller Technical Parameters Table
Model No. of Simpson SPT35LD(FD) SPT40LD(FD) SPT45LD(FD) SPT55LD(FD) SPT75LD(FD) SPT100LD(FD) SPT108LD(FD)
Rated Cooling Capacity -45~-50℃ KW 34.9 40.1 45.3 54 74.8 98.1 106.8
-55~60℃ 22.5 25.9 29.4 3.7 52.2 68.5 74.6
-65~70℃ 13.5 17.4 19.4 24.2 33.6 44.1 48
Power supply - 3Φ-380V-50Hz
Distribution Power Input Power KW 35 45 52 70 90 105 115
First stage compressor
step Compressor
Power Supply KW 17.7 19.4 23 35.9 45.6 51 59.7
Refrigerant - R404A
Starting mode - Part of the coil start Y-△
Second step compressor Power Supply KW 17.7 19.4 23 35.9 45.6 51 59.7
Refrigerant - R23
Starting mode - Part of the coil start Y-△
evaporator condenser
Condensor Evaporator
Type Type - Plate heat exchanger
evaporator
Evaporator
Type of form - Plate heat exchanger
Refrigerant flow rate Flow m3/h 15 17.2 19.4 23.1 32.1 42 45.8
Condenser Type of form - Shell and tube heat exchanger
Water flow m3/h 11.8 13.5 15.3 19.7 26.3 32.7 36.4
Take over specifications
Joint pipe diameter
Condenser mm DN40 DN50 DN50 DN65 DN65 DN80 DN80
Evaporator mm DN50 DN50 DN65 DN65 DN80 DN80 DN80
External dimensions
Dimension
Long (L) mm 2000 2200 2400 2600 2800 3000 3200
Width (W) mm 1000 1000 1100 1100 1200 1200 1300
High (H) mm 1650 1700 1700 1750 1750 1800 1850
Weight Net weight (Dry) KG 3285 3480 3540 3600 3780 4140 4650
Operating weight (Wet) KG 3614 3828 3894 3960 4158 4554 5115
Two Cascade Low Temperature Chiller Technical Parameters Table
Model No. of Simpson Unit Unit SPT130LD(FD) SPT145LD(FD) SPT168LD(FD) SPT180LD(FD) SPT195LD(FD) SPT215LD(FD) SPT235LD(FD)
Rated Cooling Capacity -45~-50℃ KW 130.2 142.9 168.4 177.9 194.6 210.7 232
-55~60℃ 90.9 99.8 117.6 124.2 135.9 147.1 162
-65~70℃ 58.6 64.3 75.7 80 87.5 94.8 104.3
Power supply - 3∮-380V-50Hz
Distribution Power Input Power KW 130 150 160 170 190 210 240
Primary compressor
First step Compressor
Power Supply KW 67.1 76.4 80.3 88.3 96.1 105.2 124.3
Refrigerant - R404A
Starting mode - Y-△
Second step compressor Power Supply KW 55.6 60.5 68.2 71.7 78.9 86.1 95.7
Refrigerant - R23
Starting mode - Y-△
evaporator condenser
Condensor Evaporator
Type Type - Plate heat exchanger
evaporator
Evaporator
Type of form - Plate heat exchanger
Refrigerant flow rate Flow m3/h 55.8 61.2 72.2 76.2 83.4 90.3 99.4
Condenser Type of form - Shell and tube heat exchanger
Water flow m3/h 43.4 48 54.3 57.9 63.4 68.9 77.5
Take over specifications
Joint pipe diameter
Condenser mm DN80 DN80 DN100 DN100 DN100 DN100 DN100
Evaporator mm DN100 DN100 DN100 DN100 DN100 DN100 DN100
External dimensions
Dimension
Long (L) mm 3400 3600 3800 3800 4000 4100 4200
Width (W) mm 1400 1500 1500 1500 1600 1600 1800
High (H) mm 1900 1900 2000 2000 2100 2100 2200
Weight Net weight (Dry) KG 3285 3480 3540 3600 3780 4140 4650
Operating weight (Wet) KG 3614 3828 3894 3960 4158 4554 5115

RE:
1. The cooling capacity is measured under temperature conditions: the refrigerant is alcohol, the inlet temperature of the cooling water is 32 ℃, and the outlet temperature is 37 ℃.
Cooling Conditions for above refrigerating capacity: Refrigerating medium is alcohol, cooling water inlet 32 ℃, outlet 37℃.
2. Scope of work: The outlet temperature of the cooling water is 22 ℃~37 ℃, and the inlet temperature difference of the cooling water is 3.5 ℃~10 ℃. The outlet temperature of the refrigerant is -40 ℃~-80 ℃, and the temperature difference between the inlet and outlet of the refrigerant is 2.5 ℃~10 ℃
Cooling range: Chilled water outlet temperature 22℃~37℃, inlet temperature difference 3.5℃~10℃. Refrigerating fluid outlet temperature -40℃~-80℃, inlet temperature difference 2.5℃~10℃.
3. Paired cooling water and refrigerant inlet and outlet connecting flanges are provided at the factory, and the refrigerant (alcohol) is provided by the user.
With pairing connecting flange for inlet and outlet of cooling water and refrigerating fluid. The refrigerating medium(alcohol) equipped by user.
4. The above specifications may change due to product improvements without prior notice. If there are special requirements, please specify them before placing an order
The above specification will change due to product improvement, without prior notice. Please contact us before order if you have special requirements .