E-mail
lyl@utestek.com
-
Phone
17301946517
-
Address
1108 Taojing Building, Minbao Road, Longhua New District, Shenzhen, Guangdong Province
Shenzhen Youce Technology Co., Ltd
lyl@utestek.com
17301946517
1108 Taojing Building, Minbao Road, Longhua New District, Shenzhen, Guangdong Province
1AC/DC current probe 1000AOverview
The CTB series current probe is a high-precision current probe capable of measuring both DC and AC currents simultaneously. It is a clamp type current sensor that can be opened/closed for AC/DC currents below 1000A. Its characteristics include: high precision, with a typical value of 0.3%; Good frequency and temperature characteristics. This product needs to be used in conjunction with CTB104 (four channel sensor unit), mainly for high-precision current measurement, and used in conjunction with a power analyzer to achieve power analysis.
IIAC/DC current probe 1000AApplication
① Power supply (switch and linear) design
② Design of new energy and electric vehicles
③ Variable frequency household appliances
④ Electrical Experiment
⑤ Inverter/Transformer Design
⑥ Electronic ballast design
⑦ Industrial Control/Consumer Electronics Design
⑧ Design of engine drive system
⑨ Power electronics and power transmission experiments, etc
⑩ Design of transportation systems (electric vehicles, locomotives, aviation electronic equipment, etc.)
3、 Option Description
CTB104 Sensor Unit: The sensor unit of the probe, with 4 channels, can simultaneously connect 4 current probes, including probe connection interface, BNC output interface, demagnetization and zero adjustment button, and power indicator light function.
4、 Product electrical specifications
Ø f.s. can reach display value or scale length (indicating rated primary current range)
Ø rdg. Read value (indicating the current value being measured and the value indicated by the measuring instrument)
Ø Input selected wave, conductor center position, CTB104 combination, excluding various influences
Measuring instruments with an input resistance of 1M Ω or more
Please demagnetize and zero correctly before measurement
| CTB20 | CTB200 | CTB500 | CTB1000 | |
| rated current | AC/DC 20A | AC/DC 200A | AC/DC 500A | AC/DC 1000A |
| bandwidth | 1MHz | 500kHz | 100kHz | 20kHz |
| Current transmission ratio | 0.1V/A | 10mV/A | 4mV/A | 2mV/A |
| input current | Reference current rated value vs. frequency curve | |||
| precision | Explanation of Reference Accuracy List | |||
| Temperature and humidity range for use | -40 ℃~85 ℃, below 80% RH (without condensation) | |||
| Ensure accuracy range | 0 ℃~40 ℃, below 80% RH | |||
| temperature coefficient | -40℃~0℃ ﹑40 ℃~85℃ Amplitude sensitivity: ± 0.02% rdg./℃ or below Bias voltage: ≤± 0.01% f.s/℃ |
|||
| Measurable conductor diameter | Below 20 mm in diameter | Below 50mm in diameter | ||
| Influence of conductor position | Below ± 0.1% RDG (20A input, DC-100Hz, Using wire with an outer diameter of 5mm |
Below ± 0.1% RDG (100A input, DC-100Hz, Using wire with an outer diameter of 5mm |
Below ± 0.2% RDG (100A input, DC-100Hz, Using wire with an outer diameter of 10mm |
Below ± 0.2% RDG (1000A input, 50/60Hz, using wire with an outer diameter of 30mm) |
| power supply voltage | ±12V | |||
| power capacity | Less than ± 200mA (measured at 20A/45Hz, powered by ± 12V) | Less than ± 250mA (measured at 200A/45Hz, powered by ± 12V) | Less than ± 300mA (measured at 500A/45Hz, powered by ± 12V) | Less than ± 300mA (measured at 1000A/45Hz, powered by ± 12V) |
5、 Certificate