Welcome Customer !

Membership

Help

Shanghai Kerui Instrument Technology Co., Ltd
Custom manufacturer

Main Products:

plast-mach>Products

Shanghai Kerui Instrument Technology Co., Ltd

  • E-mail

    hanswu1225@163.com

  • Phone

    13916002376

  • Address

    Room 302, Building B, Yanke Plaza, No. 1111 Xinzhen Street, Xinqiao Town, Songjiang District, Shanghai

Contact Now

Agilent 7010B GC/MS gas chromatography-mass spectrometry system

NegotiableUpdate on 05/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Agilent 7010B GC/MS gas chromatography-mass spectrometry system is a new version of the compact desktop triple quadrupole (MS/MS) system, which can provide an Ak level detection limit in electron impact ionization (EI) mode. 7010B adopts a brand new dynamic MRM (dMRM) mode for data acquisition, which has unprecedented ease of use and efficiency.
Product Details
brand Agilent/Agilent Origin category Import
Chromatographic type Conventional temperament price range 1.5-2 million
Instrument type TSQ Quantum GC Application field Environmental protection, food, chemical, petroleum, energy

Agilent 7010B GC/MS gas chromatography-mass spectrometry systemIt is a new version of the compact desktop triple quadrupole (MS/MS) system, which can provide Ak level detection limit in electron impact ionization (EI) mode. 7010B adopts a brand new dynamic MRM (dMRM) mode for data acquisition, which has unprecedented ease of use and efficiency.

If your laboratory has Agilent 5975 or 5977 GC/MSD systems, you can load GC/MSD SIM and Scan methods on 7010B to balance the analytical capabilities of all available instruments. An efficient EI ion source can provide more than 20 times more ions than the previous generation, greatly improving analysis efficiency.

Agilent 7010B GC/MS gas chromatography-mass spectrometry systemPerformance:

  • Improving laboratory analysis capabilities - adopting a new dMRM collection mode, the creation and editing of collection methods have become unprecedentedly simple

  • Utilize the new single quadrupole method compatibility to increase laboratory productivity - load and execute GC/MSD methods to process more samples that require SIM or Scan collection

  • Utilizing efficient EI ion sources to improve sensitivity - * EI ion sources can provide extremely low detection limits. Performance indicators verified after installation: 2 fg OFN injection, IDL ≤ 0.5 fg

  • MassHunter software not only simplifies workflows, but also controls the entire process from tuning to report generation.

  • Save time and costs - significantly simplified sample preparation procedures and reduced sample injection volume reduce daily maintenance requirements

  • Improving mass spectrometry performance - utilizing a heatable gold-plated quadrupole, three-axis HED-EM detector, and fast exhaust function to reduce common pollutants, neutral noise, and shorten cooling time

  • Greatly extend normal working hours and scheduled maintenance - integrated gas chromatography-mass spectrometry system functionality and early maintenance feedback (EMF) can match and monitor gas chromatography-mass spectrometry system operation

  • By utilizing the new JetClean intelligent hydrogen cleaning ion source upgrade option, the frequency of manual ion source cleaning can be reduced by 80%, and analysis efficiency can be improved

  • High performance chromatography - Agilent 7890B gas chromatography has a complete set of performance enhancing characteristics and can significantly save time and resources

  • The gas chromatography technology includes inert flow path, microplate flow path control technology, and programmable helium gas storage module, comprehensively optimizing the gas chromatography-mass spectrometry system

  • The method retention time lock software can reproduce the retention time of one Agilent gas chromatograph to another anytime and anywhere, allowing method transfer to be performed anywhere in the world.

  • Adopting sleep/wake mode to reduce energy consumption - In sleep mode, energy consumption can be reduced, and the system scheduler will wake up the gas chromatography-mass spectrometry system and prepare it for analysis on the next working day.