-
E-mail
hanswu1225@163.com
-
Phone
13916002376
-
Address
Room 302, Building B, Yanke Plaza, No. 1111 Xinzhen Street, Xinqiao Town, Songjiang District, Shanghai
Shanghai Kerui Instrument Technology Co., Ltd
hanswu1225@163.com
13916002376
Room 302, Building B, Yanke Plaza, No. 1111 Xinzhen Street, Xinqiao Town, Songjiang District, Shanghai
| brand | Agilent/Agilent | Origin category | Import |
|---|---|---|---|
| Chromatographic type | Conventional temperament | price range | 1.5-2 million |
| Instrument type | TSQ Quantum GC | Application field | Environmental protection, food, chemical, petroleum, energy |
Agilent 7010B GC/MS gas chromatography-mass spectrometry systemIt is a new version of the compact desktop triple quadrupole (MS/MS) system, which can provide Ak level detection limit in electron impact ionization (EI) mode. 7010B adopts a brand new dynamic MRM (dMRM) mode for data acquisition, which has unprecedented ease of use and efficiency.
If your laboratory has Agilent 5975 or 5977 GC/MSD systems, you can load GC/MSD SIM and Scan methods on 7010B to balance the analytical capabilities of all available instruments. An efficient EI ion source can provide more than 20 times more ions than the previous generation, greatly improving analysis efficiency.
Agilent 7010B GC/MS gas chromatography-mass spectrometry systemPerformance:
Improving laboratory analysis capabilities - adopting a new dMRM collection mode, the creation and editing of collection methods have become unprecedentedly simple
Utilize the new single quadrupole method compatibility to increase laboratory productivity - load and execute GC/MSD methods to process more samples that require SIM or Scan collection
Utilizing efficient EI ion sources to improve sensitivity - * EI ion sources can provide extremely low detection limits. Performance indicators verified after installation: 2 fg OFN injection, IDL ≤ 0.5 fg
MassHunter software not only simplifies workflows, but also controls the entire process from tuning to report generation.
Save time and costs - significantly simplified sample preparation procedures and reduced sample injection volume reduce daily maintenance requirements
Improving mass spectrometry performance - utilizing a heatable gold-plated quadrupole, three-axis HED-EM detector, and fast exhaust function to reduce common pollutants, neutral noise, and shorten cooling time
Greatly extend normal working hours and scheduled maintenance - integrated gas chromatography-mass spectrometry system functionality and early maintenance feedback (EMF) can match and monitor gas chromatography-mass spectrometry system operation
By utilizing the new JetClean intelligent hydrogen cleaning ion source upgrade option, the frequency of manual ion source cleaning can be reduced by 80%, and analysis efficiency can be improved
High performance chromatography - Agilent 7890B gas chromatography has a complete set of performance enhancing characteristics and can significantly save time and resources
The gas chromatography technology includes inert flow path, microplate flow path control technology, and programmable helium gas storage module, comprehensively optimizing the gas chromatography-mass spectrometry system
The method retention time lock software can reproduce the retention time of one Agilent gas chromatograph to another anytime and anywhere, allowing method transfer to be performed anywhere in the world.
Adopting sleep/wake mode to reduce energy consumption - In sleep mode, energy consumption can be reduced, and the system scheduler will wake up the gas chromatography-mass spectrometry system and prepare it for analysis on the next working day.