Physical specification parameters
Project specifications
The size of the host is not directly specified. Referring to the design of similar horizontal heating graphite furnace models, it is estimated to be about 800 × 500 × 450mm (length × width × height)
The weight of the entire machine is not clearly indicated. Considering the structure of the transverse heating graphite furnace and the automatic sampling module, it is estimated to be 70-90kg
Key Explanation
Structural feature evidence:
Adopting a transverse heating graphite furnace system (different from longitudinal heating), this design is usually more compact and has a smaller volume than traditional longitudinal heating models;
Support the combination of SPS-5 automatic sampler and SIPS-10 injection diluter, resulting in a significant increase in volume and weight after expansion.
Installation requirements:
Special graphite tubes (horizontal heating platform type) and cooling systems need to be configured, occupying additional space;
The load-bearing capacity of the workbench should be ≥ 100kg, and a maintenance channel of ≥ 50cm should be reserved around it.
Parameter missing explanation:
The search results did not provide direct size data, and the above inference is based on:
Optimization characteristics of lateral heating technology on volume;
The weight range of similar atomic absorption spectrometers (such as SpectraA-Duo220FS).
Note: It is strongly recommended to refer to the actual equipment or manufacturer's technical manual. Actual parameters may vary due to configuration (such as whether automatic sampler or cooling module is included).
Testing performance
Project specifications
Wavelength range 185-900nm
Detection limit
Graphite furnace method: detection limit for cadmium (Cd) ≤ 0.37pg (or 0.177pg)
Flame method: Copper (Cu) detection limit ≤ 0.0057mg/mL|
|Precision|
Graphite furnace method: RSD<2% (cadmium measurement)<>
Flame method: RSD<0.3% (copper measurement)>
|Sensitivity | Graphite furnace cadmium characteristic quantity 0.602pg|
Hardware configuration
Project specifications
Atomization system lateral heating graphite furnace, supporting platform graphite tubes (LTT-HP type)
Automatic injection compatible with SPS-5 automatic sampler and SIPS-10 injection dilution instrument
Multi element hollow cathode lamp with light source
The detection mode supports quick switching between flame method and graphite furnace method
Software functions include peak height/peak area measurement, automatic dilution, and rapid sequential measurement mode
Physical parameters
Project Description
The size is not clear, and the transverse heating structure design is compact (referring to similar models)
The estimated weight is around 70-90kg (including graphite furnace module)
Installation requirements include a load-bearing platform (≥ 100kg), shock-absorbing environment, and external acetylene/air source
Key Explanation
Scalability:
The SIPS-10 injection dilution instrument can automatically process high concentration samples;
The SPS-5 automatic sampler supports batch testing (with reserved operating space).
Consumables:
Special horizontal heating platform graphite tube (LTT-HP or LTT-HGO type) is required;
The flame method requires high-purity acetylene (≥ 99.8%).
Application scenarios:
Suitable for water bodies (such as chromium detection in wastewater) and trace analysis of biological samples;
The graphite furnace method is more suitable for detecting ultra trace elements such as cadmium and lead.
Note: The physical parameters are inferred values for similar models, and the actual equipment shall prevail; There are slight differences in the detection limit data, which may be due to different testing conditions.