Welcome Customer !

Membership

Help

Wuhan Hongtuo Technology Service Co., Ltd
Custom manufacturer

Main Products:

plast-mach>Products
Product Categories

Wuhan Hongtuo Technology Service Co., Ltd

  • E-mail

    13342204665@189.cn

  • Phone

    13342204665

  • Address

    No. 3 Huangjiahu West Road, Hongshan District, Wuhan City, Hubei Province

Contact Now

Second hand atomic absorption spectrophotometer price

NegotiableUpdate on 02/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Physical specification parameters, project specifications, overall weight of approximately 35kg (including standard configuration), host size not clearly marked in search results (designed as a compact desktop instrument), additional explanation, installation space requirement, experimental bench area reserved ≥ 0.8 m ² (including supporting operating space); Reserve heat dissipation space at the rear (recommended ≥ 20cm) to ensure instrument stability
Product Details

Based on the physical parameter information of Beijing Puxi TAS-990 series atomic absorption spectrophotometer in the search results, the volume and weight specifications are summarized as follows:


Physical specification parameters


Project specifications


The total weight of the machine is about 35kg (including standard configuration)


The size of the host is not clearly indicated in the search results (designed as a compact desktop instrument)


Supplementary explanation


Installation space requirements


Reserve a laboratory bench area of ≥ 0.8 m ² (including supporting operating space);


Reserve a heat dissipation space in the rear (recommended ≥ 20cm) to ensure stable operation of the instrument.


Extended accessory impact


If equipped with accessories such as an automatic sampler (such as TAS-990G), graphite furnace, or atomizer, it may result in additional weight and space occupation.


For example:


The weight of the dedicated graphite tube is about 500g per piece;


The weight of the metal sleeve glass atomizer is not disclosed (needs to be installed separately).


Note: For specific host dimensions, it is recommended to directly refer to the equipment operation manual or contact the supplier for accurate data.


The following is a comprehensive summary of the core specification parameters of Beijing Puxi TAS-990 series atomic absorption spectrophotometer:


Optical system parameters


Project specifications


Wavelength range 190-900nm


Spectral bandwidth automatically switches between five levels: 0.1nm, 0.2nm, 0.4nm, 1.0nm, and 2.0nm


Wavelength accuracy ± 0.25nm (standard model)/± 0.15nm (SUPER model)


Wavelength repeatability ≤ 0.15nm (standard model)/≤ 0.05nm (SUPER model)


Baseline drift ≤ 0.004Abs/30min (static)


Background correction


Deuterium lamp calibration: capable of calibrating 1.0Abs background


Self suction correction: capable of correcting 1.8Abs background (SUPER models up to 1.8A)|


Analyze performance parameters


Flame analysis method


Project specifications


Characteristic concentration (Cu) ≤ 0.04 μ g/mL/1% (standard model)/≤ 0.02 μ g/mL/1% (SUPER model)


Detection limit (Cu) ≤ 0.006 μ g/mL (standard model)/≤ 0.004 μ g/mL (SUPER model)


Precision (RSD) ≤ 1.0%


Graphite furnace analysis method


Project specifications


Characteristic quantity (Cd) ≤ 1.0 × 10 ⁻¹² g (standard model)/≤ 0.4 × 10 ⁻¹² g (SUPER model)


Detection limit (Cd) ≤ 1.0pg (standard model)/≤ 0.5pg (SUPER model)


Precision (RSD) ≤ 3.0%


Hardware configuration and functionality


Project specifications


Optical system dual beam design, aberration correcting C-T monochromator


Elemental lighting system with eight automatic turret lights, supporting automatic positioning and fine-tuning


Burner type: Pre mixed all titanium combustion head (flame method)


Horizontal heating design of graphite furnace technology, optimization of temperature uniformity


Security protection


Real time flame monitoring+automatic cutting off of acetylene leakage


Cooling water flow monitoring+abnormal pressure protection|


|Software Platform | AAWin 2.0 Workstation, supporting standard curve method, standard addition method, GLP specification|


Physical parameters


Project specifications


The total weight of the machine is about 35kg (including standard configuration)


Installation requirements


Experimental bench area ≥ 0.8m ² (including operating space)


Rear heat dissipation space ≥ 20cm|


Key Explanation


Model difference


Suffix identification:


F: Flame type


G: Graphite furnace type


FG: Flame+Graphite Furnace Manual Type


AFG: Flame+Graphite Furnace Automatic Type


SUPER model: higher accuracy (such as wavelength repeatability ≤ 0.05nm)


Extended functionality


Automatic sampler (such as TAS-990G) supports 60 sample grades and 8 standard sample positions


The gas flow rate adopts a mass flowmeter, which has higher accuracy than a rotor flowmeter


Operational requirements


The flame method requires an air compressor pressure of 0.2-0.3MPa and an acetylene pressure of 0.05-0.06MPa


Cooling water needs to be supplied before graphite furnace analysis, and the flow rate should be started after reaching the standard


Note: Specific parameters are subject to the equipment operation manual. Additional accessories such as atomizers and automatic samplers may require additional weight and space.