Which is a good desktop hot wire tester

NegotiableUpdate on 01/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The remote-controlled hot wire tester is a device used to test the flammability and flame resistance of materials or products under the action of high-temperature hot wires. It is widely used in industries such as electrical, electronics, and building materials. Its remote control function can improve the safety and convenience of operation. By heating a hot wire of a specified size and shape to a specific temperature (such as 550 ℃, 750 ℃, 960 ℃, etc.) and applying a certain pressure and time to the sample, the combustion behavior of the sample is observed, such as whether it catches fire, the duration of the flame, and whether there are droplets, to evaluate the flame retardant performance of the sample.
Product Details

Hot wire tester (remote control)

It is a device used to test the flammability and flame resistance of materials or products under the action of high-temperature hot wires, widely used in industries such as electrical, electronic, and building materials. Its remote control function can improve the safety and convenience of operation. Here is the relevant introduction:

working principle

By heating a specified size and shape of hot wire to a specific temperature (such as 550 ℃, 750 ℃, 960 ℃, etc.) and applying a certain pressure and time to the sample, the combustion behavior of the sample is observed, such as whether it ignites, the duration of the flame, and whether there are droplets, to evaluate the flame retardant performance of the sample.

structural composition

Heating wire component: made of nickel chromium alloy wire, it is the core component of the instrument, which can be heated to the desired temperature through heating elements and precisely controlled and monitored by a temperature control system.

Sample fixture: used to fix the sample, ensuring that the sample remains stable during the testing process and maintains the correct relative position with the hot wire.

Remote control system: equipped with a wireless remote control, the instrument can be operated from a certain distance, such as starting and stopping the test, adjusting the temperature of the heating wire, applying time, etc., to avoid close contact between operators and high-temperature components during the test process and improve safety.

Temperature measurement and control system: high-precision temperature sensors (such as thermocouples) are used to measure the temperature of the heating wire in real time, and the temperature is controlled within the specified error range through the control system to ensure the consistency of the test conditions.

Combustion chamber: provides a relatively enclosed space for testing, preventing flames, smoke, and other substances generated during the testing process from affecting the surrounding environment, while also facilitating observation of the combustion situation of the sample.

1、 Heating wire temperature: adjustable within the range of room temperature to 1000 ℃.

2、 The temperature measuring thermocouple adopts nickel chromium and nickel aluminum (K) type armored filament thermocouples with a nominal diameter of Ø 1.0mm.

3、 Heating wire is a ring made of nickel/chromium (80/20) wire with a diameter of 4mm ± 0.04mm and a specification size

4、 Maintain a pressure of 1N ± 0.2N between the heating wire and the test sample, and limit the pressing depth to 7 ± 0.5mm.

5、 The application time of the heating wire to the test sample can be adjusted within the range of 0 to 999.9 seconds. Generally set at 30 seconds according to standard requirements, with a timer for measuring ignition time and flame extinguishing time.

6、 Dimensions (length x width x height): 1150m x 690mm x 1250mm.

7、 Working power supply: AC 220V/50Hz.

1、 Heating wire temperature: adjustable within the range of room temperature to 1000 ℃.

2、 The temperature measuring thermocouple adopts nickel chromium and nickel aluminum (K) type armored filament thermocouples with a nominal diameter of Ø 1.0mm.

3、 Heating wire is a ring made of nickel/chromium (80/20) wire with a diameter of 4mm ± 0.04mm and a specification size

4、 Maintain a pressure of 1N ± 0.2N between the heating wire and the test sample, and limit the pressing depth to 7 ± 0.5mm.

5、 The application time of the heating wire to the test sample can be adjusted within the range of 0 to 999.9 seconds. Generally set at 30 seconds according to standard requirements, with a timer for measuring ignition time and flame extinguishing time.

6、 Dimensions (length x width x height): 1150m x 690mm x 1250mm.

7、 Working power supply: AC 220V/50Hz.

Hot wire tester (remote control)Main technical parameters

The temperature range of the heating wire is generally between 500 ℃ and 1000 ℃, which can be adjusted according to different testing standards and requirements. The temperature accuracy is usually ± 5 ℃.

Heating wire application time: can be set arbitrarily within the range of 0-99.9s, with an accuracy of ± 0.1s.

Sample size: It can adapt to samples of different sizes. Common sample fixtures can fix sample sizes of length x width ≤ 150mm x 150mm and thickness ≤ 60mm.

1、 Heating wire temperature: adjustable within the range of room temperature to 1000 ℃.

2、 The temperature measuring thermocouple adopts nickel chromium and nickel aluminum (K) type armored filament thermocouples with a nominal diameter of Ø 1.0mm.

3、 Heating wire is a ring made of nickel/chromium (80/20) wire with a diameter of 4mm ± 0.04mm and a specification size

4、 Maintain a pressure of 1N ± 0.2N between the heating wire and the test sample, and limit the pressing depth to 7 ± 0.5mm.

5、 The application time of the heating wire to the test sample can be adjusted within the range of 0 to 999.9 seconds. Generally set at 30 seconds according to standard requirements, with a timer for measuring ignition time and flame extinguishing time.

6、 Dimensions (length x width x height): 1150m x 690mm x 1250mm.

7、 Working power supply: AC 220V/50Hz.


灼热丝试验仪(遥控式)