Tu Xiang PaiWater cooled screw chiller unitSuitable for chemical, electroplating, ink, fiber optics, electronics, medical, industrial equipment cooling, heat source cooling, concrete mixing plants, bridge manufacturing, (for concrete and bridge manufacturing)chillerThe model has a performance 30% higher than ordinary chillers and can be customized for various occasions such as mobile refrigeration units.
Tuxiang brand water coolingScrew type chiller unitFeatures:
1、 Using high-efficiency compressors:
Selected original imported European and American brands of semi enclosed screw and semi enclosed reciprocating compressors. The compressors are selected from original imported world-renowned brands such as BITZER (Germany), HANBELL (Taiwan), RefComp (Italy), etc., with good performance, low noise, and low energy consumption. Depending on customer needs and cooling tonnage, single or multi machine combinations are used. The compressor can automatically alternate operation according to load changes, with automatic energy regulation (25% -50% -75% -100%), balancing the operating hours of each compressor, greatly extending the service life of the chiller unit.
2、 Evaporator (high-efficiency heat exchange external threaded copper tube):
The evaporator copper tube of the TuXiang brand screw chiller adopts an internally and externally threaded reinforced tube. The surface of the copper tube has threads, the outer surface of the copper tube is smooth, and the cooling effect is good. The evaporator cylinder is insulated with a 25mm thick PE insulation board, which does not condense and reduces the loss of cooling capacity.
3、 Condenser (using high-efficiency external threaded heat exchange copper tubes from Kobe, Japan):
The condenser of the Tuxiang brand screw chiller adopts copper pipes imported from foreign countries and processed into trapezoidal low assist pipes to enhance heat transfer capacity. The surface of the copper tube is smooth, reducing water pressure and making it easy to clean and maintain.
4、 Protection devices (12 types of safety protection devices, safe and fault free operation for more than 48000 hours):
The protection system devices for all industrial chillers of the TuXiang brand include temperature control switches, antifreeze switches, fusible plugs, high and low pressure switches, overload protectors, compressor overheat protectors, compressor frequent start protectors, and abnormal indicator lights.
5、 Computer control system:
The company has developed a highly intelligent PLC and PC level computer control system, which can be used for remote monitoring and control, with simple operation and connection between the host and the power supply. Low failure rate, high safety factor, and simple installation. The system control can be adjusted in real-time, intuitive and reliable.
| TX-SA Single Machine Series Low Temperature Screw Refrigerator Parameter Table | |||||||||||||
| Model number | TX-40SA | TX-60SA | TX-70SA | TX-80SA | TX-100SA | TX-120SA | TX-140SA | TX-160SA | TX-170SA | TX-180SA | TX-200SA | ||
| Cooling capacity (KW) | -10℃ | 71.8 | 94.2 | 102.8 | 124.9 | 137.2 | 186.9 | 222.8 | 265.9 | 280.9 | 307.6 | 346 | |
| -20℃ | 48.6 | 64.6 | 72 | 85.6 | 95.9 | 127.8 | 152.2 | 181.2 | 190.8 | 211.2 | 236 | ||
| -30℃ | 30.9 | 40.2 | 44.6 | 53.6 | 60 | 79.9 | 95 | 112.6 | 119.5 | 131.6 | 148 | ||
| input power | KW | 35.6 | 45.3 | 50.7 | 59.2 | 66.7 | 88 | 104.8 | 123.6 | 130.8 | 145.4 | 162 | |
| power supply | 3PH 380V 50HZ | ||||||||||||
| refrigerant | name | R22/R404A | |||||||||||
| Control method | thermal expansion valve | ||||||||||||
| compressor | type | Semi closed screw type | |||||||||||
| Power (KW) | 35.7 | 45.4 | 50.7 | 59.2 | 66.7 | 88 | 104.8 | 123.6 | 130.8 | 145.4 | 162 | ||
| condenser | type | Efficient internal thread heat exchanger (shell and tube type) | |||||||||||
| Cooling water volume (m3/h) | 19 | 24 | 27 | 32 | 35 | 48 | 57 | 67 | 71 | 78 | 88 | ||
| Pipe diameter (DN) | 75 | 100 | 125 | ||||||||||
| evaporator | type | Efficient external thread heat exchanger (shell and tube type) | |||||||||||
| Frozen water volume (m3/h) | 23 | 30 | 33 | 40 | 44 | 59 | 70 | 84 | 89 | 97 | 109 | ||
| Pipe diameter (DN) | 75 | 100 | 125 | ||||||||||
| safety protection | Compressor overload protection, overcurrent protection, high and low pressure protection, ultra-low temperature protection, flow protection, phase sequence/phase loss protection, exhaust overheating protection, antifreeze protection. | ||||||||||||
| Mechanical dimensions | Length (mm) | 1950 | 2100 | 2400 | 2400 | 2700 | 2700 | 2700 | 3100 | 3150 | 3500 | 3550 | |
| Width (mm) | 860 | 860 | 980 | 980 | 1080 | 1080 | 1080 | 1180 | 1200 | 1200 | 1300 | ||
| Height (mm) | 1550 | 1550 | 1600 | 1600 | 1700 | 1700 | 1750 | 1750 | 1750 | 1750 | 1780 | ||
| mechanical weight | Kg | 960 | 1050 | 1250 | 1350 | 1450 | 1950 | 2250 | 2450 | 2550 | 2600 | 2700 | |
| TX-SAD Dual Machine Series Low Temperature Screw Refrigerator Parameter Table | |||||||||||||
| Model number | TX-80SAD | TX-120SAD | TX-140SAD | TX-160SAD | TX-200SAD | TX-240SAD | TX-280SAD | TX-320SAD | TX-340SAD | TX-360SAD | TX-400SAD | ||
| Cooling capacity (KW) | -10℃ | 144 | 189 | 205 | 250 | 275 | 374 | 445 | 532 | 562 | 615 | 692 | |
| -20℃ | 99 | 128 | 142 | 171 | 192 | 256 | 304 | 362 | 382 | 422 | 470 | ||
| -30℃ | 62 | 80 | 89 | 107 | 120 | 160 | 190 | 226 | 238 | 264 | 294 | ||
| Input total power | KW | 71.4 | 90.8 | 101.6 | 118.8 | 133.6 | 176 | 209.7 | 247.6 | 261 | 290.8 | 324 | |
| power supply | 3PH 380V 50HZ | ||||||||||||
| refrigerant | name | R22 or R404A | |||||||||||
| Control method | thermal expansion valve | ||||||||||||
| compressor | type | Semi closed screw type | |||||||||||
| Power (KW) | 71.4 | 90.8 | 101.6 | 118.8 | 133.6 | 176 | 209.7 | 247.6 | 261 | 290.8 | 324 | ||
| condenser | type | Efficient internal thread heat exchanger (shell and tube type) | |||||||||||
| Cooling water volume (m3/h) | 37 | 48 | 53 | 64 | 70 | 94 | 112 | 133 | 142 | 155 | 175 | ||
| Pipe diameter (DN) | 100 | 125 | 150 | ||||||||||
| evaporator | type | Efficient external thread heat exchanger (shell and tube type) | |||||||||||
| Frozen water volume (m3/h) | 45 | 60 | 65 | 78 | 86 | 117 | 140 | 167 | 177 | 193 | 220 | ||
| Pipe diameter (DN) | 100X2 | 125X2 | 150X2 | ||||||||||
| safety protection | Compressor overload protection, overcurrent protection, high and low pressure protection, ultra-low temperature protection, flow protection, phase sequence/phase loss protection, exhaust overheating protection, antifreeze protection. | ||||||||||||
| Mechanical dimensions | Length (mm) | 2800 | 2930 | 2930 | 2930 | 2930 | 3500 | 3700 | 3700 | 3700 | 3700 | 4200 | |
| Width (mm) | 760 | 760 | 760 | 760 | 760 | 870 | 1300 | 1300 | 1300 | 1300 | 1500 | ||
| Height (mm) | 1730 | 1730 | 1730 | 1730 | 1730 | 1960 | 2120 | 2120 | 2120 | 2120 | 2280 | ||
| mechanical weight | Kg | 1560 | 1920 | 2250 | 2350 | 2660 | 3280 | 3960 | 4250 | 4430 | 4720 | 5320 | |
| 1、 The refrigeration capacity is measured under the following temperature adjustment conditions: the refrigerant is a 60% ethylene glycol aqueous solution; The inlet temperature of the cooling water is 32 ℃, and the outlet temperature is 37 ℃. | |||||||||||||
| 2、 Scope of work: The cooling water temperature ranges from 21 ℃ to 38 ℃, and the temperature difference between the inlet and outlet of the cooling water ranges from 3 ℃ to 12 ℃; The outlet temperature of the refrigerant is -5 ℃ to -40 ℃, and the temperature difference between the inlet and outlet of the coolant is 2 ℃ to 10 ℃. The refrigerant is a 60% ethylene glycol aqueous solution provided by the customer. | |||||||||||||
| 3、 The above specifications and dimensions are subject to actual conditions and are subject to change without prior notice. | |||||||||||||