PVDF glass rotor flowmeterDK900 Overview is a process detection instrument for measuring the flow rate of single-phase non pulsating fluids (liquids or gases) in closed pipelines. It is suitable for measuring strongly corrosive media and has the advantages of being resistant to strong acids and alkalis. PVDF material has high strength and strong corrosion resistance.

The new corrosion-resistant PVDF material product developed by Changzhou Shuangcheng Thermal Instruments has a complete range of specifications, advanced manufacturing technology, stable and reliable quality,PVDF glass rotor flowmeterThe DK900 series glass rotor flowmeter is widely used in chemical, petroleum, light industry, pharmaceutical, fertilizer, synthetic fiber, food, dye, papermaking, as well as national defense, scientific research and other units. It can also be customized with special flow rates and materials for customers to manufacture.
The glass rotor flowmeter, manufactured with professional technology and equipment, has advantages such as high measurement accuracy, good interchangeability, wide measurement range, multiple connection methods, and easy installation and maintenance compared to similar domestic products. In addition, it can provide users with flow scales for different fluids, states, and viscosities based on their physical quantities such as temperature, pressure, density, and viscosity, solving the problem of correcting measurement display values and facilitating user use.

Working Principle:PVDF glass rotor flowmeterThe DK900 series glass rotor flowmeter is a variable area flowmeter, mainly composed of a vertically expanding glass cone tube from bottom to top and a float that can move up and down with the flow rate (see Figure 1). When the fluid flows through the glass cone tube from bottom to top, the lift S and buoyancy A generated by the fluid on the float cause the float to rise. Due to the increased annular flow area between the float and the inner wall of the cone tube, the lift generated by the fluid kinetic energy on the float decreases accordingly. When the sum of lift S and buoyancy S is equal to the weight G of the float itself, the float is in equilibrium and stable at a certain height, which represents the flow rate of the fluid through the flowmeter. Because there is a certain proportional relationship between the flow rate through the flowmeter and the rising height of the float, that is, with the flow area of the flowmeter, the height position of the float can be used as two degrees of flow rate.

1、 DK900 glass rotor flowmeter specializes in technology and equipment manufacturing. Depending on its purpose and structural characteristics, it can be installed in various types such as ordinary, corrosion-resistant, and panel type, suitable for measuring small flow rates. The DK900 series glass rotor flowmeter can easily replace the glass cone tube and float without removing them from the pipeline. The DK900-2 model can measure extremely low flow rates, with a small measurement range of 0.002L/h for water and 0.1L/h for air.
Technical parameter table:
|
(1)measurement range Water(20℃)0.002~160L/h air1.2X10⁵pa,20℃)0.1~4300L/h |
(5)浮子形状:球型 , cone |
|
(6)Allow the condition of the fluid being tested High pressure:1.0Mpa, 1.6Mpa Medium temperature: -5℃~+120℃ Ambient temperature-20℃~+100℃ -20℃~+165℃ | |
(2)Scope:1:10 |
(7)Overall length:145mm |
(3)Accuracy level: 2.5level 4level |
(8)Connection method:1/4NPTinternal thread |
|
(4)Cone tube: Light tube, Reinforced pipe Length:100mm ruler Flow scale |
(9)Weight:0.4Kg |
Note: The calculation of accuracy level for imported flow meters is based on standard VDI/VDE3513. Error is taken as 1/4 reference error+3/4 relative error.
Model specification table
path(mm) |
model |
Measurement range(L/h) |
|
Water(20℃) |
air (1.2X10⁵pa,20℃) |
||
2 |
DK900-2 |
0.002~0.02 0.004~0.04 |
0.1~1.3 0.5~2.7 |
|
4 |
DK900-4 |
0.25~2.5 |
0.5~5 0.8~8 1.6~16 4~40 6~60 |
|
6 |
DK900-6 |
0.5~5 1.2~12 2.5~25 4~40 6~60 10~100 16~160 |
100~1000 180~1800 25~250 240~2400 50~500 240~2400 80~800 350~3500 100~1000 430~4300 |
Contact measurement of fluid component materials
model |
Component materials |
||||
float |
base |
stop file |
Sealing rings and gaskets |
needle valve |
|
DK900-( ) |
Agate or stainless steel coated with PTFE |
PVDF |
fluoroplastic |
Fluororubber or solvent resistant rubber |
PEK |
Note: Special materials 316 or 316L can be customized
Outline and installation dimension diagram

model |
DK900-2 DK900-2F |
DK900-4,6 DK900-4F,6F |
D(mm) |
φ9 |
φ11.5 |
E(mm) |
M8X1 |
M10X1 |
Outer diameter of metal tube(mm) |
φ5 |
φ6 |
Note: If the customer requires panel installation, special material requirements, etc., please specify them in the purchase contract. If not specified, basic models will be provided.