Welcome Customer !

Membership

Help

Changzhou Shuangcheng Thermal Instrument Factory
Custom manufacturer

Main Products:

plast-mach>Products
Product Categories

Changzhou Shuangcheng Thermal Instrument Factory

  • E-mail

    18961158186@189.cn

  • Phone

    13861234680

  • Address

    Lingqiao Village, Weicun, Changzhou City

Contact Now

Supplier of anti-corrosion glass rotor flowmeter manufacturer

NegotiableUpdate on 03/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
PVDF glass rotor flowmeter DK900 glass rotor flowmeter is a process detection instrument for measuring the flow rate of single-phase non pulsating fluid (liquid or gas) in closed pipelines. It is suitable for measuring strongly corrosive media and has the advantages of resistance to strong acid and alkali corrosion. PVDF material has high strength and strong corrosion resistance
Product Details

  PVDF glass rotor flowmeterDK900 Overview is a process detection instrument for measuring the flow rate of single-phase non pulsating fluids (liquids or gases) in closed pipelines. It is suitable for measuring strongly corrosive media and has the advantages of being resistant to strong acids and alkalis. PVDF material has high strength and strong corrosion resistance.

The new corrosion-resistant PVDF material product developed by Changzhou Shuangcheng Thermal Instruments has a complete range of specifications, advanced manufacturing technology, stable and reliable quality,PVDF glass rotor flowmeterThe DK900 series glass rotor flowmeter is widely used in chemical, petroleum, light industry, pharmaceutical, fertilizer, synthetic fiber, food, dye, papermaking, as well as national defense, scientific research and other units. It can also be customized with special flow rates and materials for customers to manufacture.

The glass rotor flowmeter, manufactured with professional technology and equipment, has advantages such as high measurement accuracy, good interchangeability, wide measurement range, multiple connection methods, and easy installation and maintenance compared to similar domestic products. In addition, it can provide users with flow scales for different fluids, states, and viscosities based on their physical quantities such as temperature, pressure, density, and viscosity, solving the problem of correcting measurement display values and facilitating user use.

Working Principle:PVDF glass rotor flowmeterThe DK900 series glass rotor flowmeter is a variable area flowmeter, mainly composed of a vertically expanding glass cone tube from bottom to top and a float that can move up and down with the flow rate (see Figure 1). When the fluid flows through the glass cone tube from bottom to top, the lift S and buoyancy A generated by the fluid on the float cause the float to rise. Due to the increased annular flow area between the float and the inner wall of the cone tube, the lift generated by the fluid kinetic energy on the float decreases accordingly. When the sum of lift S and buoyancy S is equal to the weight G of the float itself, the float is in equilibrium and stable at a certain height, which represents the flow rate of the fluid through the flowmeter. Because there is a certain proportional relationship between the flow rate through the flowmeter and the rising height of the float, that is, with the flow area of the flowmeter, the height position of the float can be used as two degrees of flow rate.

1、 DK900 glass rotor flowmeter specializes in technology and equipment manufacturing. Depending on its purpose and structural characteristics, it can be installed in various types such as ordinary, corrosion-resistant, and panel type, suitable for measuring small flow rates. The DK900 series glass rotor flowmeter can easily replace the glass cone tube and float without removing them from the pipeline. The DK900-2 model can measure extremely low flow rates, with a small measurement range of 0.002L/h for water and 0.1L/h for air.

Technical parameter table:

(1)measurement range

Water(20℃)0.002~160L/h

air1.2X10⁵pa,200.1~4300L/h

(5)浮子形状:球型 cone

(6)Allow the condition of the fluid being tested

High pressure:1.0Mpa, 1.6Mpa

Medium temperature: -5~+120

Ambient temperature-20~+100

-20~+165

(2)Scope:1:10

(7)Overall length:145mm

(3)Accuracy level: 2.5level 4level

(8)Connection method:1/4NPTinternal thread

(4)Cone tube: Light tube, Reinforced pipe

Length:100mm

ruler Flow scale

(9)Weight:0.4Kg

Note: The calculation of accuracy level for imported flow meters is based on standard VDI/VDE3513. Error is taken as 1/4 reference error+3/4 relative error.

Model specification table


path(mm)

model

Measurement range(L/h

Water(20℃)

air

1.2X10⁵pa,20

2

DK900-2


0.002~0.02

0.004~0.04

0.1~1.3

0.5~2.7



4



DK900-4




0.25~2.5

0.5~5

0.8~8

1.6~16

4~40

6~60




6



DK900-6


0.5~5

1.2~12

2.5~25

4~40

6~60

10~100

16~160

100~1000 180~1800

25~250 240~2400

50~500 240~2400

80~800 350~3500

100~1000 430~4300


Contact measurement of fluid component materials

model

Component materials

float

base

stop file

Sealing rings and gaskets

needle valve

DK900-( )

Agate or stainless steel coated with PTFE

PVDF

fluoroplastic

Fluororubber or solvent resistant rubber

PEK

Note: Special materials 316 or 316L can be customized

Outline and installation dimension diagram


model

DK900-2

DK900-2F

DK900-46

DK900-4F,6F

D(mm)

φ9

φ11.5

E(mm)

M8X1

M10X1

Outer diameter of metal tube(mm

φ5

φ6

Note: If the customer requires panel installation, special material requirements, etc., please specify them in the purchase contract. If not specified, basic models will be provided.