Welcome Customer !

Membership

Help

Hangzhou Aoke Environmental Testing Equipment Co., Ltd
Custom manufacturer

Main Products:

plast-mach>Products
Product Categories

Hangzhou Aoke Environmental Testing Equipment Co., Ltd

  • E-mail

    aoke@hzaoc.com

  • Phone

    15957190121

  • Address

    No. 10 Hengyi Street, Linping District, Hangzhou City

Contact Now

Semi automatic high and low temperature alternating humidity test chamber

NegotiableUpdate on 03/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Application of AOC product in high and low temperature alternating humidity test chamber: The product is suitable for adaptability testing of electrical and electronic products, components, parts and their materials during storage, transportation and use in high and low temperature environments, as well as temperature gradient testing. Stress screening tests can also be conducted on electronic components.
Product Details

AOC high and low temperature alternating humidity test chamber

Product Usage:
AOC high and low temperature alternating humidity test chamberThe product is suitable for adaptability testing of electrical and electronic products, components, parts and their materials during storage, transportation and use in high and low temperature environments, as well as temperature gradient testing. Stress screening tests can also be conducted on electronic components.

Technical Specifications

  1. Temperature range:-20℃~150℃(A)、-30℃~150℃(B)、-40℃~150℃(C)、

-60℃~150℃(D)、-70℃~150℃(E)

2. Humidity range:20%~98% R.H (temperature between 25 ℃~80 ℃)

3. Temperature uniformity:≤± 2 ℃ (when unloaded)

4. Humidity uniformity:+2% -3%R.H

5. Temperature fluctuation:≤± 0.5 ℃ (when unloaded)

6. Humidity fluctuation:±2%

7. Temperature deviation:≤±2℃

8. Humidity deviation:≤±2%

9. Cooling rate:0.7~1.0℃/min(When unloaded);

10.heating rate1.0~3.0℃/min

11.Power supply voltage:380V±10%

12.Total power of equipment:3KW~15KW

High and low temperature alternating humidity test chamber

refrigeration system

1. Low temperature refrigeration adopts FranceTaikang "fully enclosed compressor unit. Use R404A environmentally friendly refrigerant. Evaporative condenser serves as both a high-temperature evaporator and a low-temperature condenser

2. To ensure the safe operation of the system, high and low voltage control, overpressure, overload and other protection systems are installed in the system. At the same time, in order to monitor the operation of the system, a high voltage meter must be installed at the high voltage end to monitor the operation of the system

Heating and humidification system

1. The heater adopts a porcelain frame nickel chromium wire electric heater, which has low thermal inertia and long service life. Can be output by the instrument

Control pulse duty cyclePID signal, controlled by solid-state relay, ensuring smooth and reliable control

2. Steam boiler electric heating and humidification method, armored electric heating tube,PID control method, using contactless periodic pulse

Adjust the widthSSR (Solid State Relay) control, equipped with water level control device and heater anti dry burning device

control system

1. Control system: adopts LCD touch screen temperature controlwetDegree controller, capable of setting values and running programs.

2. Sensor:PT100 temperature sensor

3. Safety protection measures should be installed in the control system, including phase loss protection, phase sequence error protection, and fan overload protection French Taikang Compressor

Protection, over temperature, power outage protection, unit high voltage protection, unit overload protection, unit over temperature protection, leakage protection, etc

  • In addition to the main controller, an independent overtemperature protector is also installed in the system. Even if the main controller fails, the overtemperature protector can reliably disconnect the heating power supply to protect the safety of the equipment and test samples

applicablestandard

1. GB/T2423.1-200 8;

2. GB/T2423.2-2008;

3. GB/T2423.3-2006

4. GB/T2423.4-2008;

5. GB/T2423.22-2012;

6. GB/T10592-2008;

7. GB/T10589-2008;

8. GB/T10586-2006;

9. GB/T11158-2008;

10.IEC68-2-1;

11.IEC68-2-2;

12. Other standards applicable to the test conditions

produce

product

rule

grid

model

Studio size D × W × H (cm)

Dimensions D × W × H (cm)

GDJS-50

320×350×450

950870×1420

GDJS-100

400×500×500

1030×1020×1470

GDJS-150

500×500×600

1080×1050×1570

GDJS-225

500×600×750

1080×1120×1700

GDJS-250

500×600×810

1100×1120×1780

GDJS-500

700×800×900

1260×1320×1920

GDJS-800

1000×800×1000

1610×1320×1960

GDJS-010

1000×1000×1000

1610×1560×1960