Changchun Street East Section, Shuncheng District, Fushun City, Liaoning Province
Closed sampler (liquid) process diagram, nozzle table, and single unit accessory table
Taking crude benzene as an example, the medium pressure is atmospheric pressure, the medium temperature is room temperature, and the volume of the sampling bottle (glass) is 500ML.


IIOperating procedures for closed samplers (liquids)
1) Before sampling, ensure that all valves are in the closed state, install the sampling bottle, and ensure that the double needle is in place
Insert into the bottle;
2) Open the inlet valve of the medium and adjust the directional valve to the circulation mode. Shake the hand pump handle to circulate the material;
3) After sufficient circulation, adjust the directional valve to the sampling mode, and the sample enters the sampling bottle,
Observe the liquid level and close the inlet valve when the sampling amount is reached.
4)Blowing: Open the blowing valve and blow the residual crude benzene in the pipeline to the sampling bottle. Adjust the reversing valve to the circulation mode and continue blowing. After blowing is complete, close the blowing valve and adjust the reversing valve to the closed mode
5)Remove the sampling bottle and complete the sampling.
IIIotherOptional features
The above introduction shows that the liquid sealed sampler is a conventional type that collects media at room temperature and pressure. For different liquid media, the following functions can be added:
1. Heat tracing type: used for sampling low-temperature and easily condensable media
2Cooling type: used for sampling high-temperature media. The cooler can be built inside the box or externally connected separately
3Pressure reducing type: equipped with a pressure reducer, used for sampling high-pressure gaseous media to prevent overpressure damage to sampling equipment and fittings
4Filter type: used for sampling impure media with high impurities
5. Fully automatic type: One click completion of sampling operation
4、 Installation of closed sampler
The side inlet and outlet flanges of the closed sampler can be connected to the on-site inlet and outlet flanges


5、 Inquiry parameter table for closed sampler
Liaoning Bisun Petrochemical Technology Co., Ltd
Inquiry parameter table for closed sampler:
item eye |
detailed description |
medium name |
|
Operating pressure and temperature |
|
Design pressure and temperature |
|
Sampling quantity per time |
|
Tag or tag number |
|
Installation location |
|
Sampler nozzle |
|
flange |
|
quantity |
|
|
|
|
|
Reminder: Users need to provide our sales and technical personnel with effective on-site sampling medium pressure, temperature, medium type, and specific sampling environment.
Users can choose valve and pipe fittings brands for closed sampling devices! The default quotation is for the valve and pipe fittings brand selected by our company's independent closed sampler.
Keywords: closed sampler; Gas sealed sampler; High viscosity closed sampler; Hydrogen sulfide closed sampler; Sealed slurry sampler; Dopak closed sampler; Petrochemical closed sampler