Production of Karl Fischer Moisture Analyzer with Capacity Method

NegotiableUpdate on 01/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Karl Fischer titration method is a very important moisture detection method specified in the 2015 Pharmacopoeia Appendix 0832 *. Our company's S-300 fully automatic Karl Fischer titration moisture analyzer meets the requirements of the 2015 Pharmacopoeia and can quickly and accurately detect moisture in various raw materials, excipients, and finished drugs. It has been validated by hundreds of pharmaceutical industries.

Product Details

The Karl Fischer titration method is a very important moisture detection method specified in the 2015 Pharmacopoeia Appendix 0832 *. Our company's S-300 fully automatic Karl Fischer titration moisture analyzer meets the requirements of the 2015 Pharmacopoeia and can quickly and accurately detect moisture in various raw materials, excipients, and finished drugs. It has been validated by hundreds of pharmaceutical industries.

1. High precision titration system, capable of delivering up to 1 μ L in small increments;

2. The imported integrated electromagnetic three-way valve reduces the dead volume inside the valve body, and the liquid circuit switching speed only takes one hundredth of a second;

3. The integrated electromagnetic three-way valve solves the problem of traditional three-way valve leakage, with an outlet pressure of up to 100kPa. Even if the pipeline is blocked, there is no need to worry about three-way valve leakage;

4. Convenient and efficient operation interface, with multiple shortcut menus for quick access to functions. Simple and clear menu settings allow you to become an operation expert without the need for training;

5. Real time display of changes in reaction cup current allows for a more intuitive observation of the entire reaction process and more accurate measurement of the sample;

6. Provide 10 methods for setting titration speed, titration delay, and other targeted settings based on different samples, which can measure samples faster and more accurately;

7. Real time drift measuring instrument, which can monitor drift according to the changes in climate in the environment, and can set whether it needs to be deducted in the method as needed;

8. Measurement information that complies with GLP standards and can store 200 measurement results;

9. It is possible to connect to a printer and print stored measurement information.

10. Automated solvent and waste liquid suction and discharge functions make operation simpler;

11. Multiple personalized functions, including date, operator number, burette type, endpoint current, etc

12. One click cleaning, the instrument has one click cleaning functions such as power on cleaning and power off cleaning, which can be easily used without complicated operations;

A large capacity drying bottle can more effectively filter moisture in the air and reduce the impact of the environment on measurement results;

14. Fully enclosed operating environment, without contact with reagents throughout the operation, can effectively protect the safety of operators;

15. Low operating noise, almost no sound of mechanical structure operation during the entire titration process, keeping you away from noise troubles;

16. Special solvent suction pump design eliminates the siphon phenomenon caused by air pressure, which stops immediately upon pressing, allowing you to control the amount of solvent

name Technical Specifications
model S-300
measurement range 10ppm-99% water
resolution 1ppm
Polarization current ±1000MA
Small liquid inlet 1μL
burette 20ml
Accuracy of burette 1/20000
repetitiveness ≥ 99.7% (10 milligrams of water)
Large error <1%<>
resolution 1ppm
Featured Features Custom endpoint delay and titration delay; One click cleaning; Real time display of current
display screen 4.3-inch ultra large LCD display screen
Usage environment Temperature+5~+40 ℃; Humidity<80%<>
power supply 110-250V 50Hz
instrument size 340x240x300mm
Instrument weight

4kg

Guidelines for Supporting Devices

serial number name Model and Specifications
01 Automatic Karl Fischer moisture analyzer S300
02 Reaction cup components 1 set
03 drying bottle 4 of them
04 Link pipeline 13 pieces
05 reagent bottle 3 of them
06 burette assembly 1 set

Typical application

MedicationAntibiotics, chemically synthesized drugs and intermediates, pharmaceutical preparations

Organic chemical industry: Hydrocarbons, alcohols, lipids, aldehydes, organic acids

Inorganic chemical engineeringSalt, acid, alkali

petrochemicalCrude oil, gasoline, engine oil, lubricating oil

Fertilizer: Urea

pesticides: Pesticides, pesticide emulsifiers

DyeBrightener, dye, dye intermediate

Food and BeverageRice, flour, milk powder, beer

surfactantWashing powder, detergent, fabric softener

Cosmetics: facial cleanser, skincare cream, hair cream, hand oil, toothpaste