The DPD residual chlorine online analyzer detects the concentration of residual chlorine, which is an accurate, cost-effective, and low maintenance instrument suitable for measuring residual chlorine during chlorination disinfection and monitoring residual chlorine concentration in drinking water pipe networks. The reagent usage for continuous operation for 30 days (based on a 5-minute measurement cycle) enables unmanned operation with low operation and maintenance costs.
DPD residual chlorine online analyzer
GNST-CL201 uses DPD colorimetric method to detect the concentration of residual chlorine, which is a measurement toolaccurateA cost-effective and low maintenance instrument,
Suitable for measuring residual chlorine during chlorination disinfection and monitoring residual chlorine concentration in drinking water pipelines. Continuous operation for 30 days (measured in 5 minutes)
The reagent usage of the cycle meter enables unmanned operation and low operation and maintenance costs.
Application field
Suitable for residual chlorine/total chlorine measurement in chlorine disinfection processes such as tap water, circulating cooling water, and sewage, as well as residual chlorine/total chlorine measurement in tap water pipelines.
Wide power input,
7Inch touch screen design
More accurate measurement
more stableAutomatic diagnosis and calibration
Measurement cycle can be selected
Can choose between automatic or manual mode4-20mAandRS485output
relay controlData storage function, supportingUDisk export
Product Features
1DPD residual chlorine online analyzer
2Continuous operation for 30 days without the need to replace reagents, simple operation, and low maintenance costs;
3Equipped with automatic cleaning function, reducing maintenance workload;
4MODBUS RS485 output;
5Having data storage function;
6Equipped with reagent remaining alarm function;
7Measurement mode: continuous measurement mode, periodic measurement mode (adjustable measurement period).
performance
Accuracy:+/-1%
Reproducibility:+/-0.01 mg/L
Automatic zeroing: Automatically zeroing before each measurement reading
Water flow monitoring: rotating impeller water flow indicator switch
Measurable parameter: residual chlorine
5-9999min adjustable, the default factory setting of the system is 5min
Measurement range: 0.01-10 ppm (Cl); 0~14 (pH); PT100 temperature probe
Output: Analog output: 2-channel 4-20mA, expandable to 6-channel 4-20mA; Digital output: MODBUSRTU
Operation password: Yes, operator and technician
Shell: IP65 (NEMA 4)
Display: 5.5-inch monochrome character LCD display, backlight and display of alarm and status information
Job requirements
Maintenance: Replace reagents and clean filters every 1-2 months
Calibration: 6 months (pH and ORP)
Reagent consumption: up to 2 months
Power supply: 100-115 VAC, 50/60 Hz, 1.0 A or 200-230 VAC, 50/60 Hz, 0.5 A
Weight: 11kg