Price of supply sealing machine system

NegotiableUpdate on 03/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The single station high vacuum sealing machine system is mainly used for oxygen free and anhydrous vacuum sealing preservation of samples and high-temperature solid-phase synthesis. The entire system consists of a vacuum sealing machine, a hydrogen oxygen flame machine, a vacuum system, and quartz tube machine tube joints. Standardized customized quartz tubes and quartz columns ensure the coordination of other specially designed tube joints, improving the sealing performance of quartz tube packaging and achieving higher standards of vacuum sealing.

Product Details

Single station high vacuum sealing machine systemAdvantage:

Quartz tube and built-in quartz column are welded at high temperature, standardized treatment, and good repeatability.

The quartz tube is automatically rotated with a dynamic sealing system, which is easy to operate and evenly heated.

The vacuum system is equipped with a side suction device to prevent powder materials from entering the vacuum pump and extend the service life of the vacuum pump.

The hydrogen oxygen machine uses electrolyzed water gas, which is produced and used immediately, with a high safety factor.

This device is standardized in operation, ready to use, simple and convenient.

Technical Specifications:


Single station sealing machine

rotation speed

0-30rpm

Main parameters

Quartz tube specification: Φ 10/15/20/45 * 170mm (other special requirements can be customized)

Quartz tube wall thickness: 1.5-2mm (depending on flame size)

Inflatable interface: Φ 3/6mm

Whole machine leakage rate 2 * 10-10Pa.M3/s

Vacuum degree: 10-1. If higher vacuum degree is required, a molecular pump (10-4-10-5Pa) needs to be configured

Vacuum pipeline interface: KF16

structure

The device is designed with a vertical structure


Overall dimensions

600mm(L) ×260mm(W) × 290mm(H)

voltage

220V 50Hz

Net weight

15Kg

Hydrogen oxygen flame machine

Introduction

Easy to operate:No gas cylinders are needed, as long as there is water and electricity, gas can be supplied. Therefore, gas can be supplied anytime, anywhere, without being limited by time and space.

On demand gas supply:Turn on the power switch for 10 seconds to supply gas, produce as much as needed. When there is a lot of gas, the gas production will automatically stop. When the gas is not enough, it will automatically turn on to produce gas.

Non toxic and odorless:Hydrogen and oxygen are both non-toxic and odorless gases, with no risk of poisoning

Operational safety:The gas produced by the hydrogen oxygen flame machine is produced and used simultaneously without storage,

The gas supply pressure is below 0.1Mpa, so all the gas produced is used up, unlike gas cylinders which are stored under high pressure. Even with such a safe machine, we have installed six additional flame arresters: the first one is a flame arrester installed on the flame gun, the second one is a flame arrester installed on the pipeline, the third one is a flame arrester installed inside the machine, the fourth one is a one-way valve installed inside the machine, the fifth one is an explosion-proof membrane, and the sixth one is a pressure relief valve.

Variable temperature characteristics:The flame temperature can reach up to 2800 degrees and has variable temperature characteristics. When the temperature of the heated object exceeds 2800 degrees, the flame temperature also increases. For example, the hydrogen oxygen flame can melt tungsten.

火力集中:The firepower of the hydrogen oxygen flame machine is concentrated without divergence, with fast heating speed and high operational efficiency.

Catalytic characteristics:Hydrogen oxygen flame can catalyze the combustion of other solids, liquids, and gases, such as waste incineration to eliminate dioxins, and boiler combustion to eliminate waste smoke.
Multiple safeguards:The machine is equipped with leakage protection, overcurrent protection, over temperature protection, water shortage protection, and overvoltage protection.

model

OKFKJ-1000

Power input voltage(V)

220 50/60HZ

power(W/h)

3500

Types of electrolytic power sources

Efficient electrolytic power supply

gas production(rise/time)

0-1000(0-100% infinitely adjustable)

Raw material (water)

Purified water or distilled water

Working Voltage

35V

operating current

83A

Hydrogen oxygen ratio

2:1

work pressure(kg/cm2)

0.9

pressure protection(kg/cm2)

2

water consumption(L/h)

0.5

Electrolyte capacity

13Kg

security level

IP21S

Water supply mode

manual

size- LxWxH (mm)

620*505*725

gross weight(kg)

70

vacuum system

LVU-110

housing size

600 (L) x 600 (W) x 750(H)mm

Maximum carrying capacity

1000 Lbs

mechanical pump

Extraction rate:10m³/h

Oil capacity: 1.1L

Motor power: 400W

Ultimate pressure: 6 × 10-2Pa

molecular pump

Extraction rate: 100L/S

Ultimate pressure: 6 × 10-6Pa

Start time:<2 minutes

Rated speed: 4300 revolutions per minute

Cooling method: ambient temperature 5-32When it comes to air cooling; 5-40Time wise, water-cooled.

Molecular pump controller

Voltage: 220V ± 22V

Starting current: ≤ 7A

Input frequency: 47HZ-63HZ

Maximum output power: ≤ 150W

Maximum acceleration voltage: ≤ 40V

Acceleration time: ≤ 3min

Frequency (dual speed): High speed 705Hz ± 10Hz

Low speed 430Hz ± 5HZ


Composite vacuum gauge

Measurement channels: 2 channels (1 resistance gauge and 1 ionization gauge)

Working mode: manual/automatic (switchable)

Resistance unit parameters

Regulatory model: ZJ-52T resistance gauge

Measurement range: 1.0 × 105Pa~1.0 × 10-1Pa

Effective range: 2.5 × 103Pa~5.0 × 10-1Pa

Control range: 2.5 × 103Pa~5.0 × 10-1Pa

Ionizing unit parameters

Regulatory model: ZJ-27 ionization gauge

Measurable range: 5.0Pa~1.0 × 10-5Pa

Effective range: 1.0Pa~5.0 × 10-5Pa

Control range: 1.0Pa~5.0 × 10-5Pa

Regulatory degassing method: Joule degassing

Control mode: jog or zone control/with power-off memory

Control accuracy: ± 1%

Sampling time: 1 second

Power supply: 220V ± 10% 50Hz

Power consumption: 50W

Operating environment temperature: 0 ℃~45 ℃

Humidity: ≤ 85%

warranty period

One year warranty, lifetime technical support.

Special reminder: 1. Quartz tubes and quartz columns are consumables.