The LPII Rod standard vibrating rod level switch LP.II.Rod is an electronic vibration measurement system that uses mechanical principles to induce materials. The oscillating crystal causes the rod to vibrate in the air. When the material comes into contact with the rod, the vibration amplitude of the rod decreases due to the damping effect of the material; After the material leaves, it returns to free vibration. Therefore, it is not affected by the dielectric constant of the material and is very effective in the detection of lightweight powders and solid particles.
Venture must test LPII Rod standard vibrating rod level switch
Venture must test LPII Rod standard vibrating rod level switch
Venture America Must Test, LPII Rod Standard Vibration Rod Material Level Switch
Overview
LP. II. Rod switch is an electronic vibration measurement system that uses mechanical principles to
The material undergoes induction, and the oscillating crystal causes the rod to vibrate in the air. When the material comes into contact with the rod
At that time, due to the damping effect of the material, the vibration amplitude of the rod decreased; After the material leaves,
Return to free vibration. Therefore, it will not be affected by the dielectric constant of the material, especially in lightweight powders and particles
It is very effective in the detection of granular solid materials.
LP. II. Rod. Vibration rod single rod design, not easy to *, good impact resistance, sensitivity can be
Adjustment and installation are simple and fast, saving time and resources.
LP. II. Rod. vibration rod does not require calibration, achieving simple and fast installation, saving time and resources
Source. . AC/DC universal power module, convenient for flexible on-site configuration, operating within its temperature range
Within the enclosure, it can provide a low-cost and comprehensive on-site solution.
Characteristics and advantages
•AC/DC adaptive input power supplyWide voltage range to adapt to various on-site environments
•Adjustable delayBasic units are allowed LP. II. Red detected material and equipment alarms on the probe
Set a time delay between them. Enhanced units are allowed LP.II.. Red in Material Contact/Departure Detection
When using the pole, the alarm time delay can be set.
•Adjustable sensitivityDifferent sensitivities can be set according to the characteristics of different materials, with the highest possible value
Up to 24kg/m3
•Split type moduleApplied in high temperature or strong vibration environments, electronic units can reach a maximum distance of
15M
•Basic modelandEnhancedOptional, adaptable to different on-site application environments
•modular designSelection and use are more convenient
Optional interface for British metric outlet holes
Multiple process connections to adapt to on-site requirements
Comparison between Basic and Enhanced Types
| Basic model |
Enhanced |
| 2. Adjustable sensitivity |
3. Adjustable sensitivity |
| smallLong. 6-second delay
|
smallLong. 150 second delay
|
| Open the lid and use the button test |
Test using magnetic plates without opening the cover |
| AC/DC universal input power supply |
AC/DC universal input power supply |
| LED. Status indicator light |
|
| auxiliary relay |
|
Basic Parameters
| AC/DC adaptive power supply |
(± 10%),. 120~240. VAC/50/60.Hz. or. 24~48.VDC |
| power |
4.W.AC; 4.W.DC |
| fuse |
Slow melting insurance tube. 0.5. A.300. V. (non replaceable) |
| Operating Temperature |
|
| Electronic unit |
Basic type: -40 ℃~70 ℃ Explosion proof type: -20 ℃~70 ℃ (special type can achieve -40 ℃~70 ℃) |
| ... rod body |
Basic type: -30 ℃ to 95 ℃ High temperature type: -30 ℃~160 ℃ |
| output |
|
| Main relay |
8. A.DPDT. @. 240.VAC. or. 30.VDC. (resistive) |
| Auxiliary relay -. Only enhanced type |
0.46. A.SPDT. @. 150.VAC. or. 1A. @. 30.VDC |
performance
| pressure |
28.kg/cm2. (Stainless steel threaded connection) 3.5kg/cm2. (Cast aluminum threaded connection) |
| Delay - Basic model |
Delay adjustable within the range of 1 to 6 seconds |
| Delay - Enhanced |
Delay adjustable within the range of 1 to 150 seconds |
| Failure safety |
High and low material level failure safety optional |
| Sensitivity - Basic model |
Adjustable range, as small as 56kg/m3
|
| Sensitivity - Enhanced |
Adjustable range, as small as 24kg/m3
|
physics
| Shell material |
Polyester or epoxy coated cast aluminum shell or. 304. Stainless steel shell |
| Rod material |
316. Stainless steel |
| Double wire screw hole |
3/4”. NPT. or M20.x.1.5 |
| Extended steel pipe material |
316. Stainless steel |
| Shipping weight |
Basic type without extension: 4 kg |
Product Certification
UL (US & Canada)
•Ordinary places, NEMA.Type.4X; IP66
•Explosion proof places, Type.4X; IP66.
. . Class. I,. Division.1,. Groups. C.&. D
. . Class. II. ,. Division.1,. Group. E,. F.&. G
CE
•Electromagnetic compatibility certification
•Low Voltage Directive