Introduction to integrated temperature transmitter with HART protocol:
Integrated temperature transmitter with HART protocolComposed of a temperature sensor and a signal converter, the signal converter is installed in the cold junction box of the temperature sensor, directly converting the voltage and resistance signals detected by the temperature sensor into 4-20mA current output. Convert the temperature signal within the range of -200~+1600 ℃ into a two-wire 4-20mA DC electrical signal in a very simple way, and transmit it to display instruments, regulators, recorders, DCS, etc., to achieve accurate measurement and control of temperature.
Integrated temperature transmitter with HART protocolIt is an updated product for temperature measurement and control in modern industrial sites and research institutes, and is the * product of distributed systems and digital bus systems.
Integrated temperature transmitter with HART protocolType principle
The integrated temperature transmitter generally consists of a temperature measuring probe (thermocouple or thermistor sensor) and a two-wire solid-state electronic unit. The temperature probe is directly installed in the junction box in the form of a solid module, forming an integrated transmitter. Integrated temperature transmitters are generally divided into two types: thermistor and thermocouple.
The thermal resistance temperature transmitter is composed of a reference unit, R/V conversion unit, linear circuit, reverse protection, current limiting protection, V/I conversion unit, etc. After the thermal resistance signal is converted and amplified, the non-linear relationship between temperature and resistance is compensated by a linear circuit. After the V/I conversion circuit, a constant current signal of 4-20mA is output, which is linearly related to the measured temperature.
A temperature transmitter generally consists of circuit units such as a reference source, cold end compensation, amplification unit, linearization processing, V/I conversion, disconnection processing, reverse connection protection, and current limiting protection. It amplifies the thermoelectric potential generated by the thermocouple through cold junction compensation, then eliminates the nonlinear error between thermoelectric potential and temperature through a linear circuit, and finally amplifies and converts it into a 4-20mA current output signal. To prevent accidents caused by temperature control failure due to thermocouple wire breakage during thermocouple measurement, the transmitter is also equipped with a power-off protection circuit. When the thermocouple breaks or is poorly connected, the transmitter will output the maximum value (28mA) to cut off the power supply of the instrument.
The integrated temperature transmitter has the advantages of simple structure, wire saving, large output signal, strong resistance, good linearity, simple display instrument, solid module seismic and moisture-proof, reverse connection protection and current limiting protection, and reliable operation.
The output of the integrated temperature transmitter is a unified 4-20mA signal; Can be used in conjunction with microcomputer systems or other conventional instruments. Users can also request to make explosion-proof or fireproof measuring instruments.
The SBW series temperature transmitter module is a 24V powered, two-wire integrated transmitter. The product adopts imported integrated circuits to amplify the signals of thermal resistors or thermocouples and convert them into 4-20mA output current or 0-5V output voltage. The armored transmitter can directly measure the temperature of gases or liquids, and is particularly suitable for low-temperature range measurement, overcoming the influence of condensed water on temperature measurement
●Integrated temperature transmitter with HART protocolfeature
Ultra small (module diameter 44 × 18) integrated, with strong versatility
Two line system with 4-20mA DC output. long transmission distance
Cold end, temperature drift, non-linear automatic compensation.
High measurement accuracy and good long-term stability.
The temperature module adopts epoxy resin casting technology internally, which is suitable for use in various harsh and dangerous places.
Integrated design, simple and reasonable structure, can directly replace ordinary assembled thermocouples and thermistors.
Mechanical protection IP65.
Using thermocouple temperature change can eliminate the need for compensating wires and reduce costs
Various indication functions such as LCD, digital display, pointer, etc. facilitate timely monitoring on site.
When the on-site ambient temperature is above 70 ℃, the transmitter and on-site display instrument can be installed separately (isolated)
Explosion proof rating: dIIBT4, dIIBT5.
Protection level: IP54
●Integrated temperature transmitter with HART protocoltechnical indicators
| Category XS-SBW Modular Temperature Transformer XS-SBW Integrated Temperature Transformer Accuracy 0.2% 0.5% Input Thermocouples: B, S, T, K, J Thermal Resistors: Pt100, Pt10, Cu100, Cu50 Output Two wire 4-20mA DC Operating Temperature -25-85 ℃ (0-60 ℃ when integrated LCD meter head) Temperature Influence ≤ 0.05%/℃ Humidity 5-95% RH On site Display None 3 1/2 LED 3 1/2 LCD 0-Divisional Scale Display Accuracy None Digital: 0.5 Level Pointer Type: 2.0 Level Load Capacity<600 Ω (Rated Load 250 Ω) Dimensions 44 × 1870 × 100 (Relay) |
●Integrated temperature transmitter with HART protocolSelection method
model |
category |
temperature sensing element |
on-site display |
install and fix |
wiring |
protect |
Explosion proof sign |
Core structure |
Protective tube features |
Instructions |
XS-SBW |
Temperature Transmitter |
|||||||||
R |
thermocouple |
|||||||||
Z |
thermal resistor |
|||||||||
M |
镍铬硅-镍铬{ N } |
|||||||||
N |
Nickel chromium nickel silicon {K} |
|||||||||
E |
Nickel chromium copper nickel {E} |
|||||||||
F |
Iron Copper Nickel {J} |
|||||||||
C |
Copper Copper Nickel {T} |
|||||||||
P |
Platinum {Pt100} |
|||||||||
C |
Copper {Cu50} |
|||||||||
Y |
On site LCD display |
|||||||||
1 |
No fixed device |
|||||||||
2 |
fixed thread |
|||||||||
3 |
loose flange |
|||||||||
4 |
Fixed Flange |
|||||||||
5 |
Flexible tube connector type |
|||||||||
6 |
Fixed thread cone form |
|||||||||
7 |
Straight pipe joint type |
|||||||||
8 |
Fixed threaded pipe joint type |
|||||||||
9 |
Active threaded pipe joint type |
|||||||||
2 |
Anti spray type |
|||||||||
3 |
waterproof type |
|||||||||
4 |
Explosion proof type |
|||||||||
0 |
F16 |
|||||||||
1 |
F12 |
|||||||||
2 |
Ø 16 high alumina pipe |
|||||||||
3 |
Ø 20 high alumina pipe |
|||||||||
B |
flameproof |
|||||||||
none |
Ordinary component |
|||||||||
K |
Armor components |
|||||||||
F |
corrosion-resistant type |
|||||||||
N |
Wear resistant type |
|||||||||
XS-SBW |
R |
N |
Y |
2 |
4 |
0 |
B |
K |
F |
Typical Model Selection |
Integrated digital temperature transmitterThe series of products include: digital integrated temperature transmitter, integrated temperature transmitter with HART protocol, integrated temperature transmitter with thermocouple, integrated temperature transmitter with thermal resistance, intelligent temperature transmitter, etc.