Filtering of large volume culture media through particle filtration; Pilot scale production; Liquids that require pre filtration, such as media containing milk slurry; Sterilization and filtration of buffer solution; Remove mycoplasma through a 0.1 μ m membrane.
Particle removal filtration
500, 1000, and 1500Bag Filter

material
Filter material: Supor membrane (hydrophilic polyether sulfone)
Shell, ventilation holes and carrier material: polypropylene
Sealing technology: thermal bonding
Dust cover: polycarbonate
aperture size
0.1/0.1, 0.2/0.2, 0.8/0.2, and
0.8/0.45um
Effective filtration area
AcroPak 500 series: 500 cm2
AcroPak 1000 series: 1000cm2
AcroPak 1500 series: 1500 cm2
size
Diameter: 6.9cm (2.7in.)
Total length (without dust cover)
500 series products: 14.5cm (5.7in.)
1000 series products: 19.3cm (7.6in.)
1500 series products: 22.9cm (9.0in.)
Entrance/exit connection
AcroPak 500 and 1000 series products:
6.4-12.7mm (1/4-1/2-inch) hose,
Wear protective cover.
AcroPak 1500 series products:
12.7mm (1/2-inch) straight pipe interface, outlet
There is no dust cover on the mouth.
Typical residual volume of samples
(Blowing air at a pressure of 10psi)
500 series product: 30ml
1000 series products: 45ml
Large operating temperature
At 2.1 bar (210kPa, 30psi), it is
60°C (140°F)
High operational pressure
Continuous: 4.1 bar at ambient temperature
(410kPa,60psi)
Recommended integrity check small bubble point - water
0.2um: 3.5bar(350kPa、51psi)
0.45μm: 1.7bar (170kPa, 24psi)
60% IPA/40% water (v: v)
0.1μm: 2.4bar (240kPa, 35psi)
Typical water flow rate
bacterial retention
The membrane with a pore size of 0.1/0.1 μ m has achieved the desired results
A. Laidlawii has a low retention rate of no less than 107 cfu/cm2 (according to ASTM F38-83 current process).
All 0 The membranes with a pore size of 2 μ m have achieved the desired results
B. The low retention rate of diminuta bacteria shall not be less than 107rcfu/cm2 (according to ASTM F38-83 process).
When using horseshoe crab deformed cell lysate (LAL) for endotoxin level detection, it should be less than 0.25eu
Passed the United States Pharmacopeia (USP) biological reaction test
测 “In Vivo”<88>。
disinfect
Sterilization by gamma rays; If necessary, you can useUse the previous temperature range of 121-123 ° C (250-253 ° F)Sterilize under high pressure once, usually for 20 minutesThe clock.
High processing capacity and fast flow rate.
Suitable for solutions that require low protein adsorption.
The built-in pre filtration membrane increases the processing capacity, therebySaved costs.
Reliable integrity testing to ensure sterilizationFilter.
Through AcroPak capsules with 0.1 μ m Supor membraneUse a filter to ensure the removal of mycoplasma.
Oxyacetylene welding components can reduce extractable substances.
Eliminating possible EtO residues through gamma ray sterilizationPollution caused by objects.
Particle removal filtrationApplication:
Large volume culture medium filtration.
Pilot scale production.
Liquids that require pre filtration, such as those containingThe medium of milk slurry.
Sterilization and filtration of buffer solution.
Remove mycoplasma through a 0.1 μ m membrane.