Odor detector for sewage treatment plant

NegotiableUpdate on 02/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Online odor detector is the core tool for modern odor monitoring. It provides strong support for addressing odor complaints, ensuring corporate compliance, improving environmental management, and maintaining public health through continuous and data-driven monitoring methods. When selecting, it is essential to closely consider monitoring objectives, application environment, and budget, and choose products with mature technology, reliable performance, and guaranteed services.

Product Details

在线式恶臭检测仪

Online odor detector is a fixed instrument equipment that continuously, automatically, and in real-time monitors the concentration of odorous gases (or specific odor components) in the ambient air and is usually equipped with data transmission function. They are widely used in important places that require continuous monitoring of odor emissions and air quality.

  1、 Core functions and purposes:

1. Continuous monitoring: Working 24/7 without interruption, providing real-time air quality data.

2. Real time warning and alarm: When the odor concentration exceeds the preset threshold, immediately trigger an audible and visual alarm or send an alarm message (SMS, email, platform notification, etc.) for quick response.

3. Traceability and supervision: Identify the source of pollution, record the trend of concentration changes, and provide data support for environmental management and compliant emissions.

4. Compliance verification: Assist polluting units and enterprises in monitoring whether their emissions comply with national and local odor pollutant emission standards.

5. Process control and optimization: In industrial sites, it can be used to monitor odor leaks during the process and guide process optimization to reduce emissions.

6. Data networking transmission: Data is usually transmitted to monitoring platforms or environmental regulatory departments' platforms through 4G/5G, Ethernet, RS485, and other methods.

  2、 Main application scenarios:

1. Sewage treatment plant (grid, biochemical tank, sludge treatment area)

2. Landfill/garbage transfer station/garbage incineration plant

3. Fecal treatment plant/kitchen waste treatment plant

4. Food processing plant/slaughterhouse

5. Chemical plant/petrochemical plant/pharmaceutical plant

6. Paint production/printing factory

7. Livestock farms (breeding areas, manure storage and treatment facilities)

8. Odor monitoring points in public toilets/densely populated urban areas

9. Real time monitoring of odor at the boundary of the park

10. Environmental research in research institutions

  3、 Detection principle and technology:

Sensor array (electronic nose, applied to "comprehensive odor concentration"): This isoftenThe method of seeing is used to approximate the determination of "odor concentration (OU value)". It uses a set (usually 6-18) of gas sensors with different selectivity (such as metal oxide semiconductors, electrochemical sensors, etc.) to form a "sensor array". The instrument collects the response signals of all sensors and forms an "odor fingerprint". Using built-in complex mathematical models (such as PCA, PLS, ANN, etc.) and a large amount of empirical data, it "smells" and converts it into a comprehensive odor concentration index (OU value without scale) that simulates human olfactory perception. This is in line with the simulation of standard methods such as the three-point comparative odor bag method.

1. High precision specific component analyzer: for high-precision quantitative analysis of single component gases that have a significant impact on odor or require key control. Common techniques include:

-PID photoionization detector: detects organic gases below the overall or specific photoionization energy level of VOCs (such as benzene derivatives, thiols, ammonia (indirectly), etc.).

-Electrochemical sensors: detect specific gases (such as H ₂ S, NH ∝, SO ₂, NOx, etc.), with low cost but limited lifespan and anti-interference ability.

-Infrared sensors: NDIR can detect specific gases (such as CH ₄, CO ₂), while FTIR can be used for multi-component analysis (high cost).

-Semiconductor sensor: responds to some reducing gases.

2. Integrated system: The equipment may adopt the above technologies simultaneously, providing both OU values and outputting concentrations of key individual components (such as H ₂ S, NH ∝).

  4、 Key features and advantages:

1. Real time and continuity: addressing the issue of lag in manual sampling.

2. Automation and unmanned operation: significantly reducing labor costs and workload.

3. Data recording and analysis: Automatically save historical data for easy report generation, trend analysis, and tracing of pollution events.

4. Warning and rapid response: timely detection of leaks or exceeding standards, reducing environmental and risk.

5. Remote monitoring: Keep track of monitoring points anytime, anywhere.

6. Environmentally friendly: providing a data foundation for improving regional air quality and resident satisfaction.

  5、 Selection considerations (very important):

1. Detection target: Is it mainly concerned with the comprehensive odor concentration (OU value), or is it necessary to monitor several key compounds (such as H? S, NH?)? 、 TVOCs), Or both?

2. Range and accuracy: Based on the actual concentration range and required accuracy (range: such as 0-100 OU, 0-500 OU?)?; Accuracy: ±? OU) selection. Specific component analyzers need to pay attention to the detection limit.

3. Principle and Applicability: Clarify whether the principle used by the selected instrument (especially the OU simulation part) meets the monitoring purpose and possible regulatory requirements. Confirm its anti-interference ability against complex on-site environments.

4. Protection level: Industrial environments require a protection level of IP65 or even higher.

5. Explosion proof certification: Equipment that has obtained the corresponding explosion-proof level certification (such as Ex d ib mb IIC T4 Gb) must be selected in flammable and explosive areas (such as petrochemical plants).

6. Environmental adaptability: able to withstand the temperature and humidity range on site.

7. Calibration and maintenance: Understand the calibration frequency, calibration gas, convenience and cost of daily maintenance.

8. Data interface and platform: Is it convenient to access existing systems or regulatory platforms? Is the data transmission protocol compatible?

9. Manufacturer strength and after-sales service: stability, reliability, technical support, and after-sales response are crucial.

Odor detector is the core tool for modern odor monitoring. It provides strong support for addressing odor complaints, ensuring corporate compliance, improving environmental management, and maintaining public health through continuous and data-driven monitoring methods. When selecting, it is essential to closely consider monitoring objectives, application environment, and budget, and choose products with mature technology, reliable performance, and guaranteed services.

If you can provide more specific application scenarios or requirements (such as sewage plant imports, chemical fences, landfill areas, etc.), I can also provide more targeted suggestions.

  7、 Technical parameters

serial number module Configuration Name quantity parameter
1 Gas monitoring module EA200-H2S Hydrogen Sulfide Sensor 1 original Reason: electrochemistry
quantity 程: 0-5mg/m3
Detection limit: 0.05mg/m3
Resolution: 0.01mg/m3
essence Degree: ≤ 3% F.S
EA200-NH3 ammonia gas sensor 1 original Reason: electrochemistry
quantity 程: 0-20mg/m3
Detection limit: 0.05mg/m3
Resolution: 0.01mg/m3
essence Degree: ≤ 3% F.S
Odor (electronic nose) 1 original Reason: Odor
quantity Cheng: 0-2000 OU
Detection limit: 5
Resolution: 1
essence Degree: ≤ 3% F.S
EA200- C3H89N Trimethylamine Sensor 1 original Reason: electrochemistry
quantity 程: 0-5mg/m3
Resolution: 0.01mg/m3
essence Degree: ≤ 3% F.S
EA200- CH4S Methyl Thiol Sensor 1 original Reason: electrochemistry
quantity 程: 0-5mg/m3
Detection limit: 0.005mg/m3
Resolution: 0.001mg/m3
essence Degree: ≤ 3% F.S
EA200-C8H8 styrene sensor 1 original Reason: PID
quantity 程: 0-50mg/m3
Detection limit: 0.05mg/m3
Resolution: 0.01mgm3
essence Degree: ≤ 3% F.S
EA200-CS2 Carbon Disulfide Sensor 1 original Reason: electrochemistry
quantity 程: 0-50mg/m3
Detection limit: 0.05mg/m3
Resolution: 0.01mg/m3
essence Degree: ≤ 3% F.S
EA200-CH6S2 dimethyl sensor 1 original Reason: electrochemistry
quantity 程: 0-5mg/m3
Detection limit: 0.05mg/m3
Resolution: 0.01mg/m3
essence Degree: ≤ 3% F.S
EA200-C6H6S Methyl Sulfide Sensor 1 original Reason: electrochemistry
quantity 程: 0-5mg/m3
Detection limit: 0.05mg/m3
Resolution: 0.01mg/m3
essence Degree: ≤ 3% F.S
EA200-TVOC before singing 1 original Reason: PID
quantity 程: 0-50mg/m3
Detection limit: 0.05mg/m3
Resolution: 0.01mgm3
essence Degree: ≤ 3% F.S
2 Meteorological monitoring module Five meteorological parameters 1 Temperature and humidity, atmospheric pressure, wind speed, wind direction
3 Data collection and transmission data acquisition instrument 1 Main control unit/touch screen/acquisition software/remote monitoring/4G DTU
4 sampling system Supporting gas sampling 1 Sampling manifold/fan/three-level preprocessing system
5 chassis Outdoor waterproof chassis 1 Waterproof, dustproof, and anti-corrosion
6 Install the upright pole National Standard 1 3 meters, national standard anti-corrosion, outer diameter 110mm, 79mm, 2mm thick