The NIBP non-invasive blood pressure performance tester is used for performance testing, which can be used alone or connected to a PC. It provides a wide range of blood pressure simulation, adjustable pulse envelope lines, and a pressure time chart with a draggable cursor, suitable for the development and laboratory use of various types of blood pressure. Meets international medical standard testing requirements: IEC 80601-2-30, YY9706.230, and blood pressure simulator standard: ISO/TS 81060-5

BPA700Non invasive blood pressure performance tester
NIBP for performance testingNon invasive blood pressure simulatorIt can be used alone or connected to a PC, providing a wide range of blood pressure simulation, adjustable pulse envelope lines, and draggable pressure time charts, suitable for the development and laboratory use of various types of blood pressure
Meets international medical standard testing requirements: IEC 80601-2-30, YY9706.230, and blood pressure simulator standard: ISO/TS 81060-5
Product details of non-invasive blood pressure performance tester
Perform IEC80601-2-30 standard testing to ensure consistency and repeatability of dynamic blood pressure monitoring
Adjustable pulse envelope, simulating different blood pressure states
Suitable for various types of blood pressure, including wrist, arm, and tunnel styles, etc
Wide display range: including dynamic blood pressure range (10-300mmHg) and static pressure range (20-400mmHg)
At pulse volume, the dynamic pressure repeatability reaches 2mmHg, providing highly accurate test results
Provide a Software Development Kit where users can develop custom or automated testing software to improve usability and automation
The Auto sequence function assists users in easily developing semi-automatic testing processes for more efficient and automated testing
Standard auxiliary software can be selected to simplify the testing steps. Click on the option to complete the testing project for standard requirements
Standard auxiliary software automatically generates test reports and saves test records in HTML file format
rulegrid
| parameter |
specification |
| pressure unit |
Millimeter of mercury (mmHg), kilopascal (kPa) |
| Blood pressure ji |
Range: 0 to 400 mmHg Resolution: 0.1mmHg Accuracy: ± (0.3% of reading+0.5mmHg) |
| stressor |
Target pressure: 20 to 400 mmHg Stable time: 5 seconds Resolution: 1 mmHg Accuracy: ± 0.5 mmHg |
| pulse rate |
Range: 30-300 bpm Accuracy: ± 1 bpm Pulse amplitude: 2mmHg value (500ml air reserve tank) Pulse volume: 0 to 2 ml |
| waveform |
oscilloscope |
| leak test |
Test time: 0 to 300 seconds Target pressure: 20 to 400 mmHg Range: 0 to 300 mmHg/min |
| Overpressure test |
Release time: 0 to 300 seconds Range: Automatic inflation, instantaneous 0 to 400 mmHg |
| Packet offset |
Systolic pressure range: ± 20 mmHg Diastolic blood pressure range: ± 20 mmHg |
| Dynamic range |
Systolic pressure range: 10 to 250 mmHg Diastolic blood pressure range: 25 to 300 mmHg |
| Dynamic NIBP simulation repeatability |
±. 2 mmHg 0.05mmHg standard deviation |
| Self leakage rate |
< 1 mmHg = '> (500 ml air storage tank volume)
|
| environment |
Operating temperature: 10 ℃ to 40 ℃ Storage temperature: 0 ℃ to 50 ℃ Humidity: 0-90% RH (non condensing) |
| Appearance |
Size: 326.4 x 315 x 88mm Display screen: LCD (resolution 320 x 240 pixels) Weight: 4.5 kilograms |
| Connection method |
USB |
| power supply |
AC 100-240V,50/60 Hz |