Welcome Customer !

Membership

Help

Shanghai Lifutong Technology Co., Ltd
Custom manufacturer

Main Products:

plast-mach>Products
Product Categories

Shanghai Lifutong Technology Co., Ltd

  • E-mail

    lisa815@yeah.net

  • Phone

    13671818969

  • Address

    No. 8 Dongxin Street, Maqiao Town

Contact Now

How much does a static non-invasive blood pressure performance tester cost

NegotiableUpdate on 01/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The NIBP non-invasive blood pressure performance tester is used for performance testing, which can be used alone or connected to a PC. It provides a wide range of blood pressure simulation, adjustable pulse envelope lines, and a pressure time chart with a draggable cursor, suitable for the development and laboratory use of various types of blood pressure. Meets international medical standard testing requirements: IEC 80601-2-30, YY9706.230, and blood pressure simulator standard: ISO/TS 81060-5

Product Details

638296834613365114363.png

BPA700Non invasive blood pressure performance tester

NIBP for performance testingNon invasive blood pressure simulatorIt can be used alone or connected to a PC, providing a wide range of blood pressure simulation, adjustable pulse envelope lines, and draggable pressure time charts, suitable for the development and laboratory use of various types of blood pressure

Meets international medical standard testing requirements: IEC 80601-2-30, YY9706.230, and blood pressure simulator standard: ISO/TS 81060-5

Product details of non-invasive blood pressure performance tester


    • Perform IEC80601-2-30 standard testing to ensure consistency and repeatability of dynamic blood pressure monitoring

    • Adjustable pulse envelope, simulating different blood pressure states

    • Suitable for various types of blood pressure, including wrist, arm, and tunnel styles, etc

    • Wide display range: including dynamic blood pressure range (10-300mmHg) and static pressure range (20-400mmHg)

    • At pulse volume, the dynamic pressure repeatability reaches 2mmHg, providing highly accurate test results

    • Provide a Software Development Kit where users can develop custom or automated testing software to improve usability and automation

    • The Auto sequence function assists users in easily developing semi-automatic testing processes for more efficient and automated testing

    • Standard auxiliary software can be selected to simplify the testing steps. Click on the option to complete the testing project for standard requirements

    • Standard auxiliary software automatically generates test reports and saves test records in HTML file format

rulegrid

parameter specification
pressure unit Millimeter of mercury (mmHg), kilopascal (kPa)
Blood pressure ji Range: 0 to 400 mmHg
Resolution: 0.1mmHg
Accuracy: ± (0.3% of reading+0.5mmHg)
stressor Target pressure: 20 to 400 mmHg
Stable time: 5 seconds
Resolution: 1 mmHg
Accuracy: ± 0.5 mmHg
pulse rate Range: 30-300 bpm
Accuracy: ± 1 bpm
Pulse amplitude: 2mmHg value (500ml air reserve tank)
Pulse volume: 0 to 2 ml
waveform oscilloscope
leak test Test time: 0 to 300 seconds
Target pressure: 20 to 400 mmHg
Range: 0 to 300 mmHg/min
Overpressure test Release time: 0 to 300 seconds
Range: Automatic inflation, instantaneous 0 to 400 mmHg
Packet offset Systolic pressure range: ± 20 mmHg
Diastolic blood pressure range: ± 20 mmHg
Dynamic range Systolic pressure range: 10 to 250 mmHg
Diastolic blood pressure range: 25 to 300 mmHg
Dynamic NIBP simulation repeatability ±. 2 mmHg
0.05mmHg standard deviation
Self leakage rate < 1 mmHg = '> (500 ml air storage tank volume)
environment Operating temperature: 10 ℃ to 40 ℃
Storage temperature: 0 ℃ to 50 ℃
Humidity: 0-90% RH (non condensing)
Appearance Size: 326.4 x 315 x 88mm
Display screen: LCD (resolution 320 x 240 pixels)
Weight: 4.5 kilograms
Connection method USB
power supply AC 100-240V,50/60 Hz