Hot press flat plate oil heater hot press flat plate mold temperature machineUsing an electric heater as the heating element and thermal oil as the heat transfer medium, the thermal oil is driven by a circulating oil pump to circulate between the flat plate and the heater, achieving the purpose of heating and temperature control. Suitable for heating rubber vulcanization plates, EVA plastic foam plates, automotive roof molding hot plates, SMC composite material molding molds, plywood veneer hot pressing plates, etc.
Features:
1.zuiHigh operating temperature of 300 ℃
2. Explosion proof device for pipelines
3. Air blowing and oil return function (optional)
4. Return oil temperature display table
5. Heating power switching function
6. Negative pressure system operation (optional)
7. Instant cooling startup function (optional)
8. Isolation type electrical control box, extending the service life of electrical appliances
9. RS485 communication function for automated management (optional)
10. Hot oil BY-PASS pressure relief circuit
11. Multi point temperature control unit can be customized
12. Oil pump horsepower and heating power can be customized
13. Electrical appliances use OMRON, FUJI, TE, LG, MOELLER, ABB, WEST
14.304 stainless steel integrated pipeline, reducing pipe resistance and rust scale
15. Control method: Adopting imported microcomputer or (optional) PLC control
16. Comprehensive safety protection, fault display, no need for professional personnel for repair and maintenance
Detailed parameters:
model |
unit |
AEOT-20 |
AEOT-30 |
AEOT-40 |
AEOT-50 |
AEOT-75 |
AEOT-100 |
AEOT-150 |
Model |
Unit |
|||||||
Temperature control range |
℃ |
room temperature-300℃ Normal temperature-300℃ |
||||||
Tempe. range | ||||||||
Temperature control accuracy |
℃ |
PID+1℃ |
||||||
Temp. accuracy | ||||||||
power supply |
AC3∮380V 50HZ (3Phase+Earth) |
|||||||
Power | ||||||||
Heat transfer medium |
oilThermal Oil |
|||||||
Heat transfer medium | ||||||||
cooling method |
Indirect coolingIndirect cooling |
|||||||
Cooling method | ||||||||
Expansion tank capacity |
L |
35 |
35 |
40 |
40 |
75 |
75 |
100 |
Expansion tank capacity | ||||||||
heating power |
KW |
18 |
25 |
36 |
45 |
50 |
60 |
60*2 |
Heating capacity | ||||||||
Pump horsepower |
KW |
1.5 |
2.2 |
3.0 |
4.0 |
5.5 |
7.5 |
11.0 |
Pump capacity | ||||||||
Pump working flow rate |
m3/h |
1.5 |
10 |
12.5 |
16 |
12.5(18) |
25(30) |
12.5(18) |
Pump flow | ||||||||
System work pressure |
Kg/cm3 |
2.2 |
2.8 |
3.0 |
3.2 |
5.0(4.0) |
5.0(4.8) |
8.0(7.0) |
Pump pressure | ||||||||
zuiLarge power consumption |
KW |
20 |
28 |
40 |
50 |
62 |
70 |
132 |
Full capacity | ||||||||
Alarm function |
Pump reversal/lack of oil/overtemperature/overload/oil spill/Abnormal heating alarm Pump reverse/Water shortage/Over-temperature/Overload/Oil overflow /Alarm for abnormal heating |
|||||||
Alarm | ||||||||
Cooling water piping |
DN |
DN15 |
DN15 |
DN15 |
DN20 |
DN20 |
DN20 |
DN20 |
Cooling water pipe | ||||||||
Circulating water piping |
DN |
DN20 |
DN25 |
DN32 |
DN32 |
DN40 |
DN50 |
DN60 |
Circulation water pipe | ||||||||
Overall dimensions |
MM |
1200*420*1000 |
1200*420*1000 |
1500*500*1250 |
1500*550*1250 |
1750*600*1200 |
1750*600*1200 |
2000*750*1850 |
L*W*H | ||||||||