Changzhou Shuangcheng Thermal Instrument Factory provides long-term servicesNon standard customized glass rotor flowmeterWe specialize in designing and manufacturing imported flow meter replacement products, which replace imported flow meters in terms of product performance and accuracy. We also manufacture non-standard domestic flow meter products to replace mainstream countries such as the United States, Japan, South Korea, and Germany. We also provide customized samples to save customers waiting time, avoid high trade tariffs, and save costs for enterprises. The price of non-standard customization is much lower than that of imported products, making it an ideal choice for domestic manufacturers. Shuangcheng InstrumentNon standard customized glass rotor flowmeterThe minimum order quantity is satisfactory before mass customization production.
Changzhou Shuangcheng Thermal Instrument Factory provides long-term servicesNon standard customized glass rotor flowmeterLZB-( )DSeries glass rotor flowmeter
Overview
LZB-( )DSeries glass rotor flowmeter,LZB-15D stainless steel glass rotor flowmeterBy introducing technology and imitating the structure of the flow meter in Tokyo, Japan, a panel type installation is adopted, which can be equipped with regulating valves. The structure is lightweight, aesthetically pleasing, and easy to install. An alarm switch can be added, making it suitable for use at lower working pressures.
Exterior installation dimensions
LZB-15D stainless steelGlass rotor flowmeterModel specifications and technical parameters
|
path DN (mm) |
model |
Measurement range(L/min) |
accuracy wait level |
Zui high temperature (℃) |
fluid work pressure (Mpa) |
|
|
water 20℃ |
air 20℃ 101325pa |
|||||
15 |
LZB-15D |
0.3~3 0.6~6 |
4~40 10~100 20~200 |
4 |
120 |
≤0.6 |
20 |
LZB-20D |
1~10 |
2~20m³/h |
|||
25 |
LZB-25D |
0.1~1 m³/h |
3~30 m³/h |
|||
30 |
LZB-30D |
0.16~1.6 m³/h |
5~50 m³/h |
|||
Note:1LZB-15D stainless steelGlass rotor flowmeterOur company can customize flow meters with special ranges according to customer needs for measurement range
2LZB-15D stainless steelGlass rotor flowmeterIf you need to install an alarm switch, please specify in the order whether it is a fixed alarm point or an adjustable alarm point. If the switch is a proximity switch and requires a normally closed or long open function, please provide detailed instructions in the order.
Remote transmission glass rotor flowmeter
Instruction Manual



summary:
Remote transmission glass rotor flowmeter LZBSeries remote transmission rotor flowmeter, measuring tube material includesPCAnd two types of high borosilicate glass,PCMaterial suitable for non corrosive, non solvent media, working pressure4.0MPaBoric acid glass is used in corrosive media and has a pressure resistance equal toG/R/FThe connection methods of this remote type rotor flowmeter include threads, hoses, flanges, sanitary clamps, etc. This series of products has the advantages of small size, lightweight structure, beautiful appearance, easy maintenance, safety and reliability, simple installation, high measurement accuracy, low pressure loss, and good repeatability.
Remote transmission glass rotor flowmeterAppearance and installation dimensions:



Installation and Usage

Changzhou Shuangcheng Thermal Instrument Factory provides long-term servicesNon standard customized glass rotor flowmeterRemote transmission glass rotor flowmeterinstall
1Before installation, technical parameters such as measurement range, accuracy level, rated pressure, and temperature parameters should be checked to ensure they meet the usage requirements;
2Before installing the flowmeter, the measuring edge of the float should be carefully checked for damage. For flowmeters with guide rods, the filling material that prevents the float from shaking during transportation should be removed, and the cone tube should be checked for damage. The float should be able to move freely up and down to ensure that it is normal before installation.
3The flowmeter should be installed in a vertical position (the angle between the centerline of the flowmeter and the plumb line should be ≤5It should have reliable support and should not be subjected to any tension or pressure from the pipeline. When installing a new pipeline, the pipeline should be flushed clean before installing a flow meter. The measured fluid enters and exits from the lower end of the flowmeter.Attention: Do not hold any flow meter in your hand for use!
4The upper end (inlet end) of the flowmeter should have5~10It is strongly recommended to install a bypass pipeline next to the flow meter for straight pipe sections with double nominal diameter.
5Large particles of dirt should not be mixed in the measured fluid, otherwise it may cause the float to get stuck or block the flow meter passage. If necessary, a filter should be installed upstream of the flow meter.
6The measured fluid pressure must be stable. Unstable fluid pressure can cause float fluctuations and inaccurate measurement. A buffer or setting device should be installed upstream of the flowmeter.
7If there is backflow in the pipeline, especially due to water hammer, a one-way check valve should be installed after the downstream valve of the flowmeter to prevent damage to the flowmeter.
8If the measured liquid contains bubbles, an exhaust port should be installed upstream of the flowmeter.
use
1The valve upstream of the flowmeter should be slowly opened to prevent the float from suddenly rising and damaging the glass tube. Then, the downstream regulating valve should be used to adjust the flow rate. When stopping work, the upstream valve should be closed first, and then the downstream regulating valve should be closed. Suggest wrapping a metal mesh around the flowmeter to enhance safety protection.
2Avoid sudden temperature changes in the fluid being tested.
3If leakage is found in the flowmeter during use, it is usually due to the failure of the sealing ring and should be replaced.
4When the cone tube and float are contaminated, they should be cleaned in a timely manner.
5Regularly check the error of the flowmeter. Once it exceeds the specified error, the float and cone tube should be replaced or recalibrated.
6When the measured fluid and state (temperature, pressure) are different from the scale and state on the flowmeter, the displayed value must be corrected according to the measured fluid and state (including density, temperature, pressure, etc.) in order to obtain the correct flow rate.
7To obtain accurate measurement accuracy, it is recommended that the commonly used flow rate of the measured fluid should be within the range of the graduated flow rate of the rotor flowmeter60%The above is better.
8Corrosion resistant series flow meters should be selected for measuring corrosive fluids.
9Remote transmission flowmeterIt is strictly prohibited to open the lid with electricity on.
Overview
Changzhou Shuangcheng Thermal Instrument Factory provides long-term servicesNon standard customized glass rotor flowmeterDK900 glass rotor flowmeterIt is a process detection instrument for measuring the flow rate of single-phase non pulsating fluids (liquids or gases) in closed pipelines. It is suitable for measuring highly corrosive media and has the advantages of resistance to strong acids and alkalis, high strength of PVDF material, and strong corrosion resistance.
Changzhou Shuangcheng Thermal Instrument Factory provides long-term servicesNon standard customized glass rotor flowmeterThe new corrosion-resistant PVDF material product developed by Changzhou Shuangcheng Thermal Instrument has a complete range of specifications, advanced manufacturing technology, stable and reliable quality. The glass rotor flowmeter is widely used in chemical, petroleum, light industry, fertilizer, chemical fiber, food, dye, papermaking, national defense, scientific research and other units. It can also be customized with special flow rates and materials for customers.
The glass rotor flowmeter, manufactured with professional technology and equipment, has advantages such as high measurement accuracy, good interchangeability, wide measurement range, multiple connection methods, and easy installation and maintenance compared to similar domestic products. In addition, it can provide users with flow scales for different fluids, states, and viscosities based on their physical quantities such as temperature, pressure, density, and viscosity, solving the problem of correcting measurement display values and facilitating user use.
working principle
Changzhou Shuangcheng Thermal Instrument Factory provides long-term servicesNon standard customized glass rotor flowmeterDK900 glass rotor flowmeterThe series glass rotor flowmeter is a variable area flowmeter, mainly composed of a vertically expanding glass cone tube from bottom to top and a float that can move up and down with the flow rate (see Figure 1). When the fluid flows through the glass cone tube from bottom to top, the lift S and buoyancy A generated by the fluid on the float cause the float to rise. Due to the increased annular flow area between the float and the inner wall of the cone tube, the lift generated by the kinetic energy of the fluid on the float decreases accordingly. When the sum of lift S and buoyancy S is equal to the weight G of the float itself, the float is in equilibrium and stable at a certain height, which represents the flow rate of the fluid through the flowmeter. Because there is a certain proportional relationship between the flow rate through the flowmeter and the rising height of the float, that is, with the flow area of the flowmeter, the height position of the float can be used as two degrees of flow rate.
Changzhou Shuangcheng Thermal Instrument Factory provides long-term servicesNon standard customized glass rotor flowmeterDK900 series glass rotor flowmeter is a professional technology and equipment manufacturing. Depending on its purpose and structural characteristics, it can be installed in various types such as ordinary, corrosion-resistant, and panel type, suitable for measuring small flow rates. The DK900 series glass rotor flowmeter can easily replace the glass cone tube and float without removing them from the pipeline. The DK900-2 model can measure extremely low flow rates, with a small measurement range of 0.002L/h for water and 0.1L/h for air
Technical Specifications Table
|
(1)measurement range Water(20℃)0.002~160L/h air1.2X10⁵pa,20℃)0.1~4300L/h |
(5)浮子形状:球型 , cone |
|
(6)Allow the condition of the fluid being tested High pressure:1.0Mpa, 1.6Mpa Medium temperature: -5℃~+120℃ Ambient temperature-20℃~+100℃ -20℃~+165℃ | |
(2)Scope:1:10 |
(7)Overall length:145mm |
(3)Accuracy level: 2.5level 4level |
(8)Connection method:1/4NPTinternal thread |
|
(4)Cone tube: Light tube, Reinforced pipe Length:100mm ruler Flow scale |
(9)Weight:0.4Kg |
Note: The calculation of accuracy level for imported flow meters is based on standard VDI/VDE3513. Error is taken as 1/4 reference error+3/4 relative error.
Model specification table
path(mm) |
model |
Measurement range(L/h) |
|
Water(20℃) |
air (1.2X10⁵pa,20℃) |
||
2 |
DK900-2 |
0.002~0.02 0.004~0.04 |
0.1~1.3 0.5~2.7 |
|
4 |
DK900-4 |
0.25~2.5 |
0.5~5 0.8~8 1.6~16 4~40 6~60 |
|
6 |
DK900-6 |
0.5~5 1.2~12 2.5~25 4~40 6~60 10~100 16~160 |
100~1000 180~1800 25~250 240~2400 50~500 240~2400 80~800 350~3500 100~1000 430~4300 |
Contact measurement of fluid component materials
model |
Component materials |
||||
float |
base |
stop file |
Sealing rings and gaskets |
needle valve |
|
DK900-( ) |
Agate or stainless steel coated with PTFE |
PVDF |
fluoroplastic |
Fluororubber or solvent resistant rubber |
PEK |
Note: Special materials316or316LThe material can be customized
Outline and installation dimension diagram
model |
DK900-2 DK900-2F |
DK900-4,6 DK900-4F,6F |
D(mm) |
φ9 |
φ11.5 |
E(mm) |
M8X1 |
M10X1 |
Outer diameter of metal tube(mm) |
φ5 |
φ6 |
Note: If the customer requires panel installation, special material requirements, etc., please specify them in the purchase contract. If not specified, basic models will be provided
DK800Glass rotor flowmeter
Changzhou Shuangcheng Thermal Instrument Factory provides long-term servicesNon standard customized glass rotor flowmeterOverview
DK800 glass rotor flowmeter manufacturer nationwideDK800 series glass rotor flowmeterIt is a process detection instrument for measuring the flow rate of single-phase non pulsating fluid (liquid or gas) in a closed pipeline.
DK800 glass rotor flowmeter manufacturer nationwideChangzhou Shuangcheng Thermal Instrument Factory-DK800 glass rotor flowmeter manufacturerintroduceThe company's products are divided into two categories: domestic and domestic, with complete specifications and varieties, advanced manufacturing technology, and stable and reliable quality,DK800The series of glass rotor flow meters are widely used in chemical, petroleum, light industry, fertilizer, synthetic fiber, food, dye, papermaking, national defense, scientific research and other units. They can also be customized with special flow rates and materials for customers.
Glass rotor flowmeter manufacturerintroduceThe glass rotor flowmeter manufactured by the company's professional technology and equipment has the advantages of high measurement accuracy, good interchangeability, wide measurement range, multiple connection methods, and easy installation and maintenance compared to similar domestic products. In addition, it can provide users with flow scales for different fluids, different states, and different viscosities according to the physical quantities such as temperature, pressure, density, and viscosity of different fluids, solving the problem of correcting measurement display values and facilitating user use.
working principle
DK800 glass rotor flowmeter DK800 alarm series glass rotor flowmeterIt is a variable area flowmeter mainly composed of a vertically expanding glass cone tube from bottom to top and a float that can move up and down with the flow rate (see Figure 1). When the fluid flows through the glass cone tube from bottom to top, the lift generated by the fluid on the floatSThe buoyancy of fluidsARaise the float, as the annular flow area between the float and the inner wall of the cone tube increases, the lift generated by fluid kinetic energy on the float decreases accordingly. When liftSWith buoyancySThe sum is equal to the weight of the float itselfGWhen the float is in equilibrium, it stabilizes at a certain height, which represents the flow rate of the fluid through the flowmeter. Because there is a certain proportional relationship between the flow rate through the flowmeter and the rising height of the float, that is, the flow area of the flowmeter, the height position of the float can be used as two degrees of flow rate.
oneDK800Glass rotor flowmeter
Changzhou Shuangcheng Thermal Instrument Factory provides long-term servicesNon standard customized glass rotor flowmeterDK800 glass rotor flowmeter * grid manufacturer- DK800 alarm series glass rotor flowmeterIntroducing GermanyThe company specializes in technical expertise and equipment manufacturing. Depending on the purpose and structural characteristics, there are various types of installations, including ordinary, corrosion-resistant, and panel type, suitable for measuring small flow rates.DK800The series of glass rotor flow meters can be easily replaced with glass cone tubes and floats without the need to remove them from the pipeline. among whichDK800-2Type can measure extremely small flow rates, with the smallest measurement range reaching water0.002L/h,air0.1L/h
DK800 glass rotor flowmeterTechnical Specifications Table
|
(1)measurement range Water(20℃)0.002~160L/h air1.2X10?pa,20℃)0.1~4300L/h |
(5)浮子形状:球型 , cone |
|
(6)Allow the condition of the fluid being tested The biggest pressure:1.0Mpa, 1.6Mpa Medium temperature: -5℃~+120℃ Ambient temperature-20℃~+100℃ -20℃~+165℃ | |
(2)Scope:1:10 |
(7)Overall length:145mm |
(3)Accuracy level: 2.5level 4level |
(8)Connection methods: hose, metal tube, quick connector, card sleeve |
|
(4)Cone tube: Light tube, Reinforced pipe Length:100mm ruler Flow scale |
(9)Weight:0.4Kg |
Note: The calculation of the accuracy level of the imported flowmeter complies with the * standardVDI/VDE3513Error taking1/4Citation error+3/4Relative error.
Model specification table
path(mm) |
model |
Measurement range(L/h) |
|
Water(20℃) |
air (1.2X10?pa,20℃) |
||
2 |
DK800-2 DK800-2F |
0.002~0.02 0.004~0.04 |
0.1~1.3 0.5~2.7 |
|
4 |
DK800-4 DK800-4F |
0.25~2.5 |
0.5~5 0.8~8 1.6~16 4~40 6~60 |
|
6 |
DK800-6 DK800-6F |
0.5~5 1.2~12 2.5~25 4~40 6~60 10~100 16~160 |
100~1000 180~1800 25~250 240~2400 50~500 240~2400 80~800 350~3500 100~1000 430~4300 |
Contact measurement of fluid component materials
model |
Component materials |
||||
float |
base |
stop file |
Sealing rings and gaskets |
needle valve |
|
DK800-( ) |
Agate or316Lstainless steel |
HPb59-1brass |
nylon |
Nitrile rubber |
304stainless steel |
DK800-( ) F |
304stainless steel |
fluoroplastic |
Fluororubber or solvent resistant rubber |
||
Note: Special materials316or316LThe material can be customized
Outline and installation dimension diagram
model |
DK800-2 DK800-2F |
DK800-4,6 DK800-4F,6F |
D(mm) |
φ9 |
φ11.5 |
E(mm) |
M8X1 |
M10X1 |
Outer diameter of metal tube(mm) |
φ5 |
φ6 |
Note: If the customer requires panel installation, special material requirements, etc., please specify them in the purchase contract. If not specified, basic models will be provided