Cold and hot shock test chamber/main technical indicators:
1. Temperature range: High temperature chamber: 60~+200 ℃; Low temperature box: -70~0 ℃; Test chamber: -55~85 ℃.
2. Temperature fluctuation: ± 0.5 ℃
3. Temperature deviation: ≤± 2 ℃ (with load)
4. Dimensions: Depth 1100 * Width 1200 * Height 1850mm;
5. Studio dimensions: depth 400 * width 400 * height 500mm;
6. Refrigeration system: Bitzer semi enclosed compressor unit, water-cooled; The remaining main refrigeration components are all imported parts.
7. Heating system: Stainless steel dedicated heating tube with aluminum fins for heat dissipation.
8. Sheet metal structure: Made of SUS304 all stainless steel.
9. Heating power: 23KW;
10. Control system: Adopting Japanese OYO touch screen program temperature controller, all other major electrical appliances are imported parts.
11. Operation mode: Program running
Cold and hot shock test chamber/equipment usage:
This cold and hot temperature shock test chamber is mainly designed for adaptability testing of electronic and electrical products, as well as their raw components and other materials, during storage, transportation, and use in environments with rapid conversion from high to low temperatures. This cold and hot temperature shock test chamber is mainly used to conduct environmental simulation tests on the physical and other related characteristics of products under low and high temperature rapid impact conversion conditions in accordance with national standards or user defined requirements. After testing, the performance of the product is judged through inspection to determine whether it still meets the predetermined requirements, for product design, improvement, identification, and factory inspection.
Cold and hot shock test chamber/safety protection device:
1. Power overload and short circuit protection
2. Grounding protection
3. Overtemperature protection
4. Compressor overpressure protection
4. To protect the equipment, all alarms will automatically cut off the power and sound a warning.