High Temperature Aging Chamber
Product Introduction:
The walk-in high-temperature laboratory is used for temperature environment testing of electronic, automotive, rubber, plastic, aerospace technology, technology and communication equipment or large products that require a large amount or scale simultaneously. So as to determine whether the reliability and stability performance parameters of the product are qualified. We will provide you with a basis for predicting and improving the quality and reliability of our products.
Purpose:
This product is widely used in high and low temperature laboratory for routine high and low temperature tests, cold resistance tests, and low temperature storage of large parts, semi-finished products, and finished products, in order to analyze and evaluate the performance and behavior under the proposed environmental conditions during the test.
Main features of high temperature laboratory:
1. It is mainly composed of control panel, distribution panel, insulation storage board, air supply fan, heater, and freezer. The main specifications are divided into six standard internal dimensions and twenty-four different test specifications under different conditions.
2. Adopting a combination of storage board units, the content area can be arbitrarily enlarged, easy to disassemble and assemble, and can be designed according to customer size requirements, and can be adjusted to accommodate customer relocation during factory expansion.
3. The material inside the warehouse board is made of SUS # 304 stainless steel, and the outer material is made of SECC or color steel plate with spray coating treatment. The structure is sturdy, waterproof, and beautiful.
4. Axial flow fan is used, and the upper air duct of the laboratory is designed with upper air outlet and lower return air to avoid any dead corners and ensure even distribution of indoor temperature and humidity.
5. Programmable touch screen controllers such as WINCON from the United States, UNIQUE from Japan, and OYO can be connected to a computer via RS-232 interface. Users can design programs, collect test data and records, call program execution, and remotely control machine power on/off on the computer screen.
When an abnormal situation occurs, the controller screen automatically displays the fault status in real time, cuts off the computer switch, and provides troubleshooting methods.
7. The refrigeration unit adopts European and American compressors and uses environmentally friendly refrigerants. The refrigeration system adopts a binary cascade refrigeration design and uses different compressors to work in different temperature ranges to increase the service life of the equipment.
High Temperature Aging Chamber
Main technical parameters:
Model XF-6.8P
Test area size (W × H × D cm) 180 × 210 × 180
Performance temperature range+85 ℃~-65 ℃ (A: 0 ℃; B: -20℃; C: -40℃; D: -65℃)
Temperature fluctuation ± 0.5 ℃
Temperature deviation: ± 2.0 ℃
Heating time+25 ℃~+85 ℃
≤60min
Cooling time+25 ℃~Limit low temperature
30min-180min (varies depending on different models)
External material: SECC steel plate+foundation make-up baking paint
Internal material SUS # 304 stainless steel plate
Insulation material PU and insulation cotton
Temperature and humidity regulation system, refrigeration machine, European and American * fully enclosed or semi enclosed compressor
Refrigerant R134a/R404a/R23
Axial flow fan, side blowing or upward blowing
High performance heater
Cooling method: Air cooled or water-cooled binary cascade cooling method
The controller display can be programmed with touch screen series from WINCON in the United States, UNIQUE in Japan, and OYO; Standard models: RKC, OYO series
Programmable display accuracy: WINCON from the United States, UNIQUE from Japan, OYO: temperature 0.01 ℃;
Standard type: RKC: Temperature 0.1 ℃
Running mode, program mode, constant value mode
Control method, calculus operation, PID
Signal input platinum resistor PT100
Observation window multi-layer hollow coated heating glass
Other accessory testing holes (two with a diameter of Φ 50mm or depending on the customer), one lighting fixture inside the box or depending on the customer
Safety device over temperature protection; Leakage protection; Compressor overpressure, overload
Overcurrent protection; Fan overload protection; phase sequence protection
Power supply AC 380V (1 ± 10%) V, 50 ± 0.5HZ, three-phase four wire+protective ground wire
Optional temperature and humidity recorder, capable of simultaneously recording temperature signals
High Temperature Aging Chamber
We can also produce according to the size requirements of the customer to meet their needs.
ZBG stands for walk-in high and low temperature
P is programmable, S is standard type
A. B, C, D represent temperature range (A: 0 ℃; B: -20℃; C: -40℃; D: -65℃