Fully automatic Shanghai vibration testing platform manufacturer

NegotiableUpdate on 01/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Shanghai vibration testing platform complies with the standards and test methods: GB/T2423.10-2008 "Environmental Testing for Electrical and Electronic Products - Part 2: Test Methods - Test Fc: Vibration (Sinusoidal)"; GB/T18287-2013 "Technical specifications for safety certification of lithium-ion batteries and battery packs for portable electronic products"; GB31241-2014 "Safety Requirements for Lithium ion Batteries and Battery Packs for Portable Electronic Products" UN38.3 IATA "Dangerous Goods Regulations"; GJB4477-200

Product Details

ShanghaiVibration TestTaiwanIt simulates various vibration environments encountered by products during production, assembly, transportation, and operation, and realizes all functions required for vibration testing, including sine wave, frequency modulation, sweep frequency, programmable, frequency doubling, logarithmic, large acceleration, amplitude modulation, and time control. It is used to identify whether products can withstand various complex environmental vibrations and is suitable for research, development, quality control, and manufacturing in various industries such as electronics, electromechanical, automotive, toys, packaging, etc. It is a high-tech equipment for improving product quality reliability and entering the high-quality field.

Shanghai Vibration Testing Platform

Implement standards and test methods that meet the requirements:

GB/T2423.10-2008 "Environmental testing for electrical and electronic products - Part 2: Test methods - Test Fc: Vibration (sine)";

GB/T18287-2013 "Technical specifications for safety certification of lithium-ion batteries and battery packs for portable electronic products";

GB31241-2014 "Safety Requirements for Lithium ion Batteries and Battery Packs for Portable Electronic Products"

UN38.3 IATA Dangerous Goods Regulations;

GJB4477-2002 "Standard: General Specification for Lithium ion Battery Pack";

QC/T743-2006 "Lithium ion Batteries for Electric Vehicles";

UL1642 "Lithium Battery Standard" and other related standards.

GB4351.1-2005《Portable fire extinguishers can undergo vibration tests on dry powder fire extinguishers.

Shanghai Vibration Testing Platform

model

Table size(mm)

direction of vibration

XF / ICT-500VT

500*500

vertical+level+longitudinalDirection is optional

XF/ZDT-750VT

750*750

vertical+level+longitudinalDirection is optional

XF/ZDT-010VT

1000*1000

vertical+level+longitudinalDirection is optional

material

high-quality steel plate/Iron plate/stainless steel / aluminiumoptional

Test load

100 kg (load can be increased according to demand)

frequency range

1Hz~600Hz/5000Hz (adjustable) higher frequency range available for selection

amplitude/displacement

0-5mm (adjustable)

Large acceleration

≤20g-30gM/s2 (per square second per meter)

direction of vibration

X- Y - ZUp and down, left and right, front and back

Vibration waveform

Sine wave (half wave/full wave)

function

sineWave, FM, sweep, programmable

time control

Any time can be set (in seconds)

frequency converter

Taiwan, China Delta / ABB Precision 0.1Hz

power supply

220v50Hz

power

0.75 / 2.2 / 3.5KW

calculation formula

1. High acceleration 20g (1g=9.8 m/s2), adjust the amplitude to determine the acceleration,Large acceleration=0.002 × f2 (frequency HZ) × D (amplitude MMP-p),Example: 10Hz high acceleration=0.002 × 102 × 5=1g,Acceleration should not exceed 20g at any frequency

2. Large amplitude<5mm.Large amplitude=20/(0.002 × f2)

Example: 100Hz large amplitude=20/(0.002 × 1002)=1mm,The amplitude cannot exceed 5mm at any frequency

3. The higher the frequency, the smaller the amplitude

To see the correct numbers for amplitude and acceleration, a measuring instrument needs to be purchased separately

Special table size, special test load, special amplitude customization