Features:
1. Digital sensor, direct outputRs-485 digital signal, supporting MODBUS/RTU
2. Built in temperature and pressure sensors, capable of automatic compensation; Built in salinity compensation
3. Optical design, no need to consume electrolyte, measurement without consuming oxygen
4. Add filter design, anti light source interference, good stability
5. No preheating required, no polarization required, fast response speed,40 second response time (T90)
6. The fluorescent cap head is easy to replace, with lower maintenance costs and a longer service life
7. Surface anti-corrosion and passivation treatment
8. Low power consumption of sensors and anti-interference design of internal circuits
Technical Specifications
name |
parameter |
output signal |
supportRs-485,MODBUS/RTUagreement |
measurement method |
fluorescence quenching |
range |
0~20mg/L(0~200%saturation) |
precision |
±2%F.S.,±0.5℃ |
resolution |
0.01mg/L,0.1℃ |
working conditions |
0~45℃、<0.2mpa<> |
calibration method |
two-point calibration |
response time |
40 seconds T90 |
temperature compensation |
Automatic temperature compensation(Pt1000) |
power supply |
12 or 24VDC ± 10%, 10mA; |
size |
diameter30mm;length189mm; |
Protection level |
IP68;水深20 meters; |
service life |
sensor3 years or more; Membrane head: 1 year or more |
Cable length |
5 meters (default), customizable |
Sensor housing material |
stainless steel or POM(Other) |
|

Maintenance and precautions
lSuggest everyClean the sensor membrane head attachment within 30 days; Avoid using hard objects to scratch the fluorescent film head during cleaning; Please wipe with a soft damp cloth.
lIt is recommended to clean the outer surface of the sensor with water flow. If there are still debris residues, please wipe them with a damp soft cloth.
lFluorescent film head: Do not use sharp objects to scratch the fluorescent film head;Once the fluorescent material is scraped off, the dissolved oxygen value cannot be accurately measured and the fluorescent film head needs to be replaced.
lReplace the fluorescent cap: The fluorescent cap is connected to the sensor body through threaded fastening, and a waterproof sealing ring is used in the middle; Do not miss the sealing ring when replacing.
lInstallation measurement: Avoid conducting installation measurement in areas with turbulent water flow to reduce the impact of water bubbles on the measurement.
lDaily storage: When not in use for a long time, use a protective cover with moist cotton for storage. Long term dry storage requires soaking before useUse after 48 hours.
Suggestion: Choose our company's protective cover to prevent microbial attachment from affecting measurement results