Differential Scanning Calorimeter (DSC) quotation

NegotiableUpdate on 02/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The main features of the imported TA differential scanning calorimeter DSC from the United States are: truly synchronized TGA/DTA, TGA/DSC measurement dual balance design, truly differential heat flow signal isolated reaction gas pathway, dual sample TGA function correction technology, dynamic normalization processing of DSC data
Product Details

TA Differential Scanning Calorimeter (DSC) imported from the United StatesTechnical parameters:

Structural Design: Horizontal Furnace and Balance

Balance design: Dual bar dual balance design (automatic expansion compensation)

Sample capacity: 200mg (including sample tray up to 350mg)

Balance sensitivity: 0.1 μ g

Furnace type: Double wire winding

Temperature range: Room temperature~1500 ℃

Heating rate - from room temperature to 1000 ℃: 0.1-100 ℃/min Heating rate

Heating rate - from room temperature to 1500 ℃: 0.1-25 ℃/min Heating rate

Furnace cooling: forced air (from 1500 ℃ to 50 ℃<30 minutes)

Thermocouple: Platinum/Platinum Rhodium (R-type)

Temperature correction: Curie point of metal standard sample (one to five points)

DTA sensitivity: 0.001 ℃

Calorimetry accuracy/precision:+/-2% (based on metal standards)

Digital Mass Flow Controller

And gas automatic gas switch: standard configuration

Vacuum degree: up to 7Pa (0.05Torr)

Reactive gas inlet: standard (independent intake pipe)

Double sample TGA testing: standard configuration

Automatic optimized cloth step constant temperature technology: standard configuration

Sample crucible:

Platinum: 40 μ L, 110 μ L

Alumina: 40 μ L, 90 μ L

TA Differential Scanning Calorimeter (DSC) imported from the United StatesKey Features:

Truly synchronized TGA/DTA, TGA/DSC measurements

Dual balance design

True differential heat flow signal

Isolated reaction gas pathway

Dual sample TGA function

Correction technology

Dynamic normalization processing of DSC data

Thermal balance

The Q600 adopts a highly reliable horizontal dual arm double balance structure, which can simultaneously complete DSC and TGA measurements. The weight signal given is the difference between the weight signals of the sample arm and the reference arm. In fact, both will automatically deduct the thermal expansion and buoyancy effects of the balance arm. Therefore, compared to the design of a single arm beam, its result drift is smaller, and the accuracy and precision of weight testing are also higher. Users can benefit from the high sensitivity, accuracy, and precision of the instrument when testing small weight changes (0.1 μ g). Meanwhile, the uniqueness of the instrument lies in its ability to independently perform TGA measurements on two samples simultaneously.

Purging gas system

The Q600 adopts a blowing air path design with proven performance level through long-term practice. The Q600 is equipped with a digital mass flow controller and a gas automatic switch, which controls the horizontal flow of the blowing gas through the heating furnace body, passes through the sample and reference plate, and then flows out of the furnace chamber. Reactive gases can enter through the independent Inconel600 gas tube, which can protect the balance components and effectively blow the sample. Export can be easily combined with mass spectrometers or infrared analyzers. This design ensures better baseline stability, smaller buoyancy effects, prevents gas backflow, and effectively carries decomposed substances out of the sample area.

High resolution SDT

If the standard method (maintaining a linear heating rate throughout the experiment) cannot separate adjacent weight loss phenomena, Q600 also provides an automatic step constant temperature (SWI) method, a classic technique for increasing TGA resolution. This method involves heating the sample at a constant heating rate until the weight loss rate or total weight loss exceeds the limit SHI set by the operator, and the instrument remains at that temperature until the weight loss process is complete. Every time the weight loss process occurs, this heating and constant temperature step is repeated to obtain the weight loss resolution.

After sales service commitment:

Warranty period: 1 year

Can the warranty period be extended: Yes

On site technical consultation: Yes

Free training: unlimited number of times

Free instrument maintenance: once a year

Warranty maintenance commitment: 1 year warranty period

Repair commitment: arrive at the site within 8-24 hours