DC high voltage generatorAdopting an intermediate frequency voltage doubling circuit, utilizing PWM intermediate frequency pulse width modulation technology, closed-loop adjustment, and adopting voltage feedback to significantly improve voltage stability. Use high-performance high-power IGBT devices and their driving technology, and adopt special shielding, isolation, and grounding measures based on electromagnetic compatibility theory. makeDC high voltage generatorIt has high quality, portability, and can withstand rated voltage discharge without damage.
The main components of the instrument are selected from advanced technologies from countries such as the United States, Germany, and Japan, making the instrument more reliable and stable. The pressure doubling cylinder has a small volume, large capacity, strong overload capacity, and is convenient for on-site operation and testing. Our company regards quality and reputation as our lifeblood, constantly improving our technological level and developing high-quality products to meet the needs of our customers.
1. On site DC high voltage testing by the power supply department, such as DC withstand voltage and leakage testing of power cables, conductivity current and 1mA reference voltage testing of magnetic blown lightning arresters and zinc oxide lightning arresters.
2. It can be used as a laser power supply and also for electrostatic spraying, electrostatic weaving, and other applications.
3. Other occasions that require high DC voltage.
4. The addition of high-precision 75% VDC-1mA function brings great convenience to the measurement of zinc oxide lightning arresters. A gentle press does not require calculation. There are 75% voltage function keys on the control box of this instrument. During the lightning arrester test, when the current rises to 1000uA, press 0.75UDC
5. All products manufactured by our company have undergone strict quality inspection, and all indicators are superior to the requirements of the power industry standard DL447.2-92 of the People's Republic of China.

Main parameters:
1. Power supply: AC220V ± 10%, 50Hz ± 1%
2. Rated output voltage: 60kV, 120kV, 200kV, 300kV, 400kV, 600kV, 800kV
3. Rated output current: 2mA, 3mA, 5mA, 8mA, 10mA
4. Output current indication accuracy:<1 level<>
5. Output voltage indication accuracy:<1 level<>
6. Ripple factor: ≤ 0.5
7. 0.75 times output voltage indication accuracy:<1 level, with latch>
all-in-one
Specifications and Technical Parameters |
40/3 |
60/2 |
60/3 |
60/5 |
80/2 |
100/2 |
120/2 |
120/5 |
Rated voltage (kV) |
40 |
60 |
60 |
60 |
80 |
100 |
120 |
120 |
Rated current (mA) |
3 |
2 |
3 |
5 |
2 |
2 |
2 |
5 |
Rated power (W) |
120 |
120 |
180 |
300 |
160 |
200 |
240 |
600 |
Chassis weight (kg) |
7 |
2 |
2 |
4.5 |
2 |
3 |
3 |
4.5 |
Double pressure weight (kg) |
integrated |
2.5 |
3 |
3.8 |
2.5 |
4 |
4 |
4.5 |
Double pressure height (mm) |
integrated |
400 |
400 |
500 |
400 |
500 |
500 |
500 |
Voltage measurement accuracy |
Digital display meter ± (1.0% reading ± 2 words) |
|||||||
Accuracy of current measurement |
Digital display meter ± (1.0% reading ± 2 words) |
|||||||
Ripple coefficient |
≤1% |
|||||||
voltage stability |
Random fluctuation, ≤ 1% when the power supply voltage changes by ± 10% |
|||||||
overload capacity |
The no-load voltage can exceed the rated voltage by 10% and be used for ten minutes. The maximum charging current is 1.5 times the rated current |
|||||||
power supply |
Single phase AC 50Hz 220V ± 10% |
|||||||
working method |
Intermittent use |
|||||||
The longest continuous time is 30 minutes | ||||||||
working environment |
Temperature: -10~40 ℃ |
|||||||
Relative humidity: not exceeding 85% at room temperature of 25 ℃ (no condensation) | ||||||||
Altitude: below 1500 meters | ||||||||
Capacity with capacitive load |
The capacitance of the test sample is unlimited |
|||||||
Can be charged with 1.5 times the rated current | ||||||||
structural characteristics |
Epoxy fiberglass electrical insulation double pressure cylinder |
|||||||
Air insulation, no leakage concerns | ||||||||
Characteristics of the operation box |
High precision 0.75UDC1mA single touch button (accuracy ≤ 1.0%) zinc oxide lightning arrester test |
|||||||
Overvoltage protection adopts a toggle setting, which is clear at a glance | ||||||||
Place an aluminum alloy box with double voltage on the chassis, and the entire machine can be lifted with one hand | ||||||||
split-type unit
Specifications |
200/2 |
200/3 |
200/5 |
300/2 |
300/3 |
300/5 |
Rated voltage (kV) |
200 |
200 |
200 |
300 |
300 |
300 |
Rated current (mA) |
2 |
3 |
5 |
2 |
3 |
5 |
Rated power (W) |
400 |
600 |
1000 |
600 |
900 |
1500 |
Chassis weight (kg) |
4.5 |
4.5 |
4.5 |
5.5 |
5.5 |
5.5 |
Double pressure weight (kg) |
7.9 |
7.9 |
8.3 |
11 |
11 |
11.5 |
Double pressure height (mm) |
970 |
970 |
970 |
1250 |
1250 |
1250 |
Voltage measurement accuracy |
Digital display meter ± (1.5% reading ± 2 words) |
|||||
Accuracy of current measurement |
Digital display meter ± (1.5% reading ± 2 words) |
|||||
Ripple coefficient |
≤3% |
|||||
voltage stability |
Random fluctuation, ≤ 1% when the power supply voltage changes by ± 10% |
|||||
overload capacity |
The no-load voltage can exceed the rated voltage by 10% and be used for ten minutes |
|||||
power supply |
Single phase AC 50HZ 220V ± 10% |
|||||
working method |
Intermittent use |
|||||
The longest continuous time is 10 minutes | ||||||
working environment |
Temperature: -10~40 ℃ |
|||||
Relative humidity: not exceeding 85% at room temperature of 25 ℃ (no condensation) | ||||||
Altitude: below 1500 meters | ||||||
With capacitor |
The capacitance of the test sample is unlimited |
|||||
Can be charged with 1.5 times the rated current | ||||||
structural characteristics |
Epoxy fiberglass electrical insulation double pressure cylinder |
|||||
Air insulation, no leakage concerns | ||||||
Characteristics of the operation box |
High precision 0.75UDC1mA single touch button (accuracy ≤ 3%) |
|||||
Overvoltage protection adopts a toggle setting, which is clear at a glance | ||||||
Dual use standard chassis for standing and sleeping, convenient for on-site use | ||||||