YW Explosion proof Submersible Sewage Pump Product Overview
The YW submersible sewage pump is a vertical submersible structure. During operation, the pump body is immersed in water, and the depth of the liquid can reach 0.5-5m. It adopts a unique single blade or double blade impeller structure, which can effectively pass fiber materials with a diameter of 5 times the pump diameter and solid particles with a diameter of 50% of the diameter. The product complies with the JB/T6525-92 "Technical Conditions for Centrifugal Sewage Pumps" standard.
Product features of YW explosion-proof submersible sewage pump
1. Variable liquid level installation depth: The unit is a vertical underwater structure, which can be installed at different depths according to user requirements, making it extremely convenient to use.
2. Single tube or double tube installation: This type of pump can be installed in different ways according to user requirements; Single or double tube installation is available.
3. Reduce maintenance costs: The mechanical seal made of new materials and high-quality bearings greatly improve the safety of the seal and the reliability of the unit.
4. Strong overcurrent capability: The special impeller anti blocking design ensures efficient and unobstructed operation.
Working conditions of YW explosion-proof submersible sewage pump
Flow rate: 2-850 m3/h
Head range: 3-45m
Rated speed n: 1450~2900r/min
Medium temperature: -15 ℃~+60 ℃
Medium density: ≤ 1.3 × 103kg/m3
Medium pH value: 5-9
System high working pressure: ≤ 0.6Mpa
Structural diagram of YW explosion-proof submersible sewage pump| Serial Number | Component Name | Serial Number | Component Name | ![]() |
| 1 | electrical machinery | 5 | main shaft | |
| 2 | coupling | 6 | mechanical seal | |
| 3 | Motor support | 7 | pump body | |
| 4 | Outlet pipe | 8 | impeller |
| Serial Number | Component Name | Serial Number | Component Name | ![]() |
| 1 | electrical machinery | 5 | main shaft | |
| 2 | coupling | 6 | mechanical seal | |
| 3 | Motor support | 7 | pump body | |
| 4 | Outlet pipe | 8 | impeller |
| Serial Number | Component Name | Serial Number | Component Name | ![]() |
| 1 | electrical machinery | 5 | main shaft | |
| 2 | coupling | 6 | mechanical seal | |
| 3 | Motor support | 7 | pump body | |
| 4 | Outlet pipe | 8 | impeller |
For details, please refer to: YW type submerged unobstructed sewage pump (structural diagram) YW type submerged unobstructed sewage pump (curve diagram) YW type submerged unobstructed sewage pump (installation dimensions)
YW explosion-proof submersible sewage pump product usage
Enterprise wastewater discharge. Urban sewage treatment plant discharge system. Subway, basement, civil air defense system drainage station. Wastewater discharge from hospitals, hotels, and high-rise buildings. Sewage drainage stations in residential areas. Discharge of slurry in municipal engineering and construction sites. The water supply system of a water plant. YW submersible sewage pump for wastewater discharge from aquaculture farms and irrigation of rural farmland. Exploration of YW submersible sewage pump for mining and supporting water treatment equipment. Instead of carrying people's shoulders, suck and transport river mud. The operating conditions for YW submersible sewage pump are water temperature ≤ 60 ℃ and liquid pH value between 4-10.
| Model number | Caliber (mm) |
Traffic volume (m3/h) |
Head lift (m) |
Power (kw) |
Rotational speed (r/min) |
Efficiency (%) |
| YW25-8-22-1.1 | 25 | 8 | 22 | 1.1 | 2825 | 38.5 |
| YW32-12-15-1.1 | 32 | 12 | 15 | 1.1 | 2825 | 40 |
| YW40-15-15-1.5 | 40 | 15 | 15 | 1.5 | 2840 | 45.1 |
| YW40-15-30-2.2 | 40 | 15 | 30 | 2.2 | 2840 | 48 |
| YW50-20-7-0.75 | 50 | 20 | 7 | 0.75 | 1390 | 54 |
| YW50-10-10-0.75 | 50 | 10 | 10 | 0.75 | 1390 | 56 |
| YW50-20-15-1.5 | 50 | 20 | 15 | 1.5 | 2840 | 55 |
| YW50-15-25-2.2 | 50 | 15 | 25 | 2.2 | 2840 | 56 |
| YW50-18-30-3 | 50 | 18 | 30 | 3 | 2880 | 58 |
| YW50-25-32-5.5 | 50 | 25 | 32 | 5.5 | 2900 | 53 |
| YW50-20-40-7.5 | 50 | 20 | 40 | 7.5 | 2900 | 55 |
| YW65-25-15-2.2 | 65 | 25 | 15 | 2.2 | 2840 | 52 |
| YW65-37-13-3 | 65 | 37 | 13 | 3 | 2880 | 55 |
| YW65-25-30-4 | 65 | 25 | 30 | 4 | 2890 | 58 |
| YW65-30-40-7.5 | 65 | 30 | 40 | 7.5 | 2900 | 56 |
| YW65-35-50-11 | 65 | 35 | 50 | 11 | 2930 | 60 |
| YW65-35-60-15 | 65 | 35 | 60 | 15 | 2930 | 63 |
| YW80-40-7-2.2 | 80 | 40 | 7 | 2.2 | 1420 | 52 |
| YW80-43-13-3 | 80 | 43 | 13 | 3 | 2880 | 50 |
| YW80-40-15-4 | 80 | 40 | 15 | 4 | 2890 | 57 |
| YW80-65-25-7.5 | 80 | 65 | 25 | 7.5 | 2900 | 56 |
| YW100-80-10-4 | 100 | 80 | 10 | 4 | 1440 | 62 |
| YW100-110-10-5.5 | 100 | 110 | 10 | 5.5 | 1440 | 66 |
| YW100-100-15-7.5 | 100 | 100 | 15 | 7.5 | 1440 | 67 |
| YW100-85-20-7.5 | 100 | 85 | 20 | 7.5 | 1440 | 68 |
| YW100-100-25-11 | 100 | 100 | 25 | 11 | 1460 | 65 |
| YW100-100-30-15 | 100 | 100 | 30 | 15 | 1460 | 66 |
| YW100-100-35-18.5 | 100 | 100 | 35 | 18.5 | 1470 | 65 |
| YW125-130-15-11 | 125 | 130 | 15 | 11 | 1460 | 62 |
| YW120-130-20-15 | 125 | 130 | 20 | 15 | 1460 | 63 |
| YW150-145-9-7.5 | 150 | 145 | 9 | 7.5 | 1440 | 63 |
| YW150-180-15-15 | 150 | 180 | 15 | 15 | 1460 | 65 |
| YW150-180-20-18.5 | 150 | 180 | 20 | 18.5 | 1470 | 75 |
| YW150-180-25-22 | 150 | 180 | 25 | 22 | 1470 | 76 |
| YW150-130-30-22 | 150 | 130 | 30 | 22 | 1470 | 75 |
| YW150-180-30-30 | 150 | 180 | 30 | 30 | 1470 | 73 |
| YW150-200-30-37 | 150 | 200 | 30 | 37 | 1480 | 70 |
| YW200-300-7-11 | 200 | 300 | 7 | 11 | 970 | 73 |
| YW200-250-11-15 | 200 | 250 | 11 | 15 | 970 | 74 |
| YW200-400-10-22 | 200 | 400 | 10 | 22 | 1470 | 76 |
| YW200-400-13-30 | 200 | 400 | 13 | 30 | 1470 | 73 |
| YW200-250-15-18.5 | 200 | 250 | 15 | 18.5 | 1470 | 72 |
| YW200-300-15-22 | 200 | 300 | 15 | 22 | 1470 | 73 |
| YW200-250-22-30 | 200 | 250 | 22 | 30 | 1470 | 71 |
| YW200-350-25-37 | 200 | 350 | 25 | 37 | 1980 | 75 |
| YW200-400-30-55 | 200 | 400 | 30 | 55 | 1480 | 70 |
| YW250-600-9-30 | 250 | 600 | 9 | 30 | 980 | 74 |
| YW250-600-12-37 | 250 | 600 | 12 | 37 | 1480 | 78 |
| YW250-600-15-45 | 250 | 600 | 15 | 45 | 1480 | 75 |
| YW250-600-20-55 | 250 | 600 | 20 | 55 | 1480 | 73 |
| YW250-600-25-75 | 250 | 600 | 25 | 75 | 1480 | 73 |
| YW300-800-12-45 | 300 | 800 | 12 | 45 | 980 | 76 |
| YW300-500-15-45 | 300 | 500 | 15 | 45 | 980 | 70 |
| YW300-800-15-55 | 300 | 800 | 15 | 55 | 980 | 73 |
| YW300-600-20-55 | 300 | 600 | 20 | 55 | 980 | 75 |
| YW300-800-20-75 | 300 | 800 | 20 | 75 | 980 | 78 |
| YW300-950-20-90 | 300 | 950 | 20 | 90 | 980 | 80 |
| YW300-1000-25-110 | 300 | 1000 | 25 | 110 | 980 | 82 |
| YW350-1100-10-55 | 350 | 1100 | 10 | 55 | 980 | 84.5 |
| YW350-1500-15-90 | 350 | 1500 | 15 | 90 | 980 | 82.5 |
| YW350-1200-18-90 | 350 | 1200 | 18 | 90 | 980 | 83.1 |
| YW350-1100-28-132 | 350 | 1100 | 28 | 132 | 740 | 83.2 |
| YW350-1000-36-160 | 350 | 1000 | 36 | 160 | 740 | 78.5 |
| YW400-1500-10-75 | 400 | 1500 | 10 | 75 | 980 | 82.1 |
| YW400-2000-15-132 | 400 | 2000 | 15 | 132 | 740 | 85.5 |
| YW400-1700-22-160 | 400 | 1700 | 22 | 160 | 740 | 82.1 |
| YW400-1500-26-160 | 400 | 1500 | 26 | 160 | 740 | 83.5 |
| YW400-1700-30-200 | 400 | 1700 | 30 | 200 | 740 | 83.5 |
| YW400-1800-32-250 | 400 | 1800 | 32 | 250 | 740 | 82.1 |
| YW500-2500-10-110 | 500 | 2500 | 10 | 110 | 740 | 82 |
| YW500-2600-15-160 | 500 | 2600 | 15 | 160 | 740 | 83 |
| YW500-2400-22-220 | 500 | 2400 | 22 | 220 | 740 | 84 |
| YW500-2600-24-250 | 500 | 2600 | 24 | 250 | 740 | 82 |
Before using the pump, carefully inspect the pump and motor for any damage Check the tightness of fasteners.
2. Check for any friction sound when turning the pump Simultaneously check the concentricity between the pump shaft and the motor shaft The deviation of the outer circle of the two couplings shall not exceed 0.5mm
3. Connect the pipeline to the pump outlet A separate bracket should be installed It is not allowed to add its weight to the pump body.
4. Unless otherwise specified, the water pump must be equipped with a fully automatic water pump control cabinet Do not directly connect to the power grid or use a knife switch to connect the current Ensure the normal operation of the water pump
5. Do not operate the water pump in a low head state for a long time (generally, the head used should not be less than 60% of the rated head) It can be controlled within the recommended range of head The motor of the waterproof pump was burned out due to overload
Maintenance and upkeep
1. The water pump should be managed and used by a dedicated person Regularly check the circuit and operation of the water pump.
2. After each use, especially for thicker and more viscous slurries The water pump should be placed in the cooling water and run for several minutes Prevent sedimentation inside the pump Ensure the cleanliness of the water pump.
3. Under normal conditions The pump should be filled or replaced with oil (10-30 # oil) in the oil chamber every 300-500 hours of use Keep the mechanical seal in good lubrication condition Improve the service life of mechanical seals.
The sealing ring between the impeller and the pump body has a sealing function If the sealing ring is damaged, it will directly affect the performance of the pump If necessary, it should be replaced.
Ordering Notice
1、 ① Product name and model of submersible sewage pump ② Diameter of submersible sewage pump ③ Head of submersible sewage pump (m) ④ Motor power of submersible sewage pump (KW) ⑥ Rotation speed of submersible sewage pump (r/min) ⑦ Voltage of submersible sewage pump [V] ⑧ Suction stroke of submersible sewage pump (m) ⑨ Whether the submersible sewage pump comes with accessories for us to correctly select for you.
2、 If the design unit has already selected the model of our company's submersible sewage pump product, please order directly from the sales department of Yangtze River Pump Industry Company according to the model of the submersible sewage pump.
3、 When the usage situation is very important or the environment is complex, please provide design drawings and detailed parameters as much as possible, and our technical experts from Yangtze River Pump Industry will review and control them for you.