E-mail
13001661057@163.com
-
Phone
15376395192
-
Address
No.16 Longteng Road, Shangma Industrial Park
Qingdao Xinye Environmental Protection Technology Co., Ltd
13001661057@163.com
15376395192
No.16 Longteng Road, Shangma Industrial Park
Xinye XY-6900A Portable Open Channel Flow Meter APP Version

1、 Technical background and application
In order to implement the Environmental Protection Law of the People's Republic of China and the Water Pollution Prevention and Control Law of the People's Republic of China, protect the ecological environment, and safeguard peoplePhysical health, and2019year12moon24On the day, the "Online Monitoring System for Water Pollution Sources" was released(CODCrTheNH3-N wait)Installation TechnologyStandardization and Online Monitoring System for Water Pollution Sources(CODCrTheNH3-N wait)Acceptance Technical Specifications. In the 'Installation Technical Specification', it is proposed toIn the composition of the online monitoring system, a flow monitoring unit is required. For the discharge units that need to measure the flow, a standardized metering weir for open channels should be built
(Slot))And the construction of the weir should be able to conduct comparison work of open channel flow meters. It is recommended to use triangular weir, rectangular weir, and Bacher trough. In the 'Acceptance Techniques'In the "Technical Specifications", specific requirements are proposed for the acceptance method of water pollution source flow monitoring units, which are divided into liquid level error comparison and flow error comparison
According to the above requirements, it can be seen that portable open channel flow meters are required for on-site acceptance, and continuous statistical records should be kept during the acceptance processLiquid level data and flow data need to be provided in12Synchronize recording of online open channel flow meters and portable sewage flow meters within minutes6A liquid level data, and in
10Synchronize recording of online open channel flow meters and portable sewage flow meters within minutes2Accumulated data of open channel flow, and because the sewage flow has been monitoredCheng is irreversible. Once there are problems during the recording process, it is necessary to conduct a new comparison and acceptance, and provide on-site verification in both time and spaceCollecting work has brought difficulties.
In response to the current lack of portable sewage flow meters in China that can easily and quickly complete the above acceptance tasks, our company utilizes multiple methodsYears of experience in developing environmental monitoring instruments, combined with the 'Online Monitoring System for Water Pollution Sources'(CODCrTheNH3-N wait)Installation Technical Specifications "and" Online Monitoring System for Water Pollution Sources "(CODCrTheNH3-N wait)Acceptance Technical Specifications "and《HJ 15-2019Technical requirements for ultrasonic open channel sewage flowmeterDevelop a portable open channel flowmeter that meets the on-site acceptance requirements for flow meters based on the technical and functional requirements outlined in the "Exploration and Testing Methods"Flowmeter.
This portable open channel flow meter is mainly used for on-site technical parameter evaluation and acceptance of online open channel sewage flow meters, and can also be extended to flow measurement of open channel sewage discharge in enterprises.
IIXinye XY-6900A Portable Open Channel Flow Meter APP VersionFeatures
(1)adapt totenType of Weir: Triangle Weir Rectangular weir Equal width weir Basher troughRectangular wide topped weir、Circular edged broad topped weir、Trapezoidal thin-walled weir、No throat groove、Triangular section weir、flatVType weir;
(2)High precision signal acquisition module,24 Accuracy of data collection, accurate and valid measurement data;
(3)7inchLarge screen color LCD touch screen, touch guided operation, easy operation process;
(4)Surrounding environment display, capable of measuring atmospheric pressurestrongTemperature recording;
(5)OptionalPositioning function, supportsBDS/GPSSingle system positioning of satellite navigation systems, as well as multi system joint positioning in any combination;
(6)A friendly human-computer interaction interface, combining graphics and text, allowing for instrument operation without the need for professional knowledge;
(7)The instrument is equipped with a micro printer, which can directly print measurement data on site;
(8)Data recording can be done throughUSBexportUplate,Output to the computer for easy statistical analysis of data by users;
(9)storable 20000 The measurement history of the second time;
(10)Contains a large capacity lithium battery that can be continuously measured on a single charge72 Hour;
(11)The flowmeter is equipped with an intelligent power management system, which extends the battery life;
(12)Can be operated through a mobile phone for long-distance communication, not limited by spatial distance;
(13)Handheld box design, lightweight and convenient for users to carry.
IIItechnical indicators
ØFlow measurement range:0~40m3/s;
ØFlow measurement frequency:3 time/s;
ØLiquid level resolution:0.1mm
ØLiquid level measurement:≤0.5mm;
ØFlow measurement five times:≤±1%;
ØSensor range:1Meter (standard),2Rice (optional).
ØSignal output mode:USB;
ØWorking environment humidity:≤85%;
ØWorking environment temperature: 10℃~40℃;
ØMeasurement temperature range:-40℃-80℃
ØMeasurement range of atmospheric pressure:0-120Kpa
Ø定位精度:2.5Mi,Cold start capture sensitivity:-148dBmTracking sensitivity:-162dBm(optional)
Øchargepower supplyAC 220V ±15%;
ØBuilt in battery:DC16.8VLithium batteries; Battery powered continuous working time:72 h;
ØOverall dimensions:400mm×300mm×110mm(host),900100 x 100 (Attachment Package);
ØTotal weight of the machine about4kg.
Ø
4execution standard:
JJG711-1990 "Trial Verification Regulations for Open Channel Weir Flow Meter"
HJ/T15-2019 "Technical Requirements and Testing Methods for Ultrasonic Open Channel Sewage Flowmeters"
HJ 354-2019 Technical Specification for Acceptance of Online Monitoring System for Water Pollution Sources (CODCr, NH3-N, etc.)
HJ355-2019 Technical Specification for Operation of Online Monitoring System for Water Pollution Sources (CODc, NH-N, etc.)