1、 Product Introduction
CLJ-3016 type(Upgraded version)Mask factoryDust particle counter2.83LAs a laser light source, it is used to measure the size and number of dust particles per unit volume of air in clean environments, and can directly detect clean environments with cleanliness levels ranging from level 10 to 300000. This instrument adopts a semiconductor laser light source, a large LCD screen display, small size, light weight, high detection accuracy, simple and clear functional operation, microprocessor control, can store and print measurement results, and is very convenient for testing in a clean environment.
2、 Technical parameters
1. Sampling volume: 2.83L/min (1cfm/min)
2. Detection scope:100 to 300000 levels (A, B, C, D, E levels)
3. Sampling period: 1-10 (min)
4. Self purification time: ≤ 10 (min)
5. Measurement method:Simultaneous display of six gears
6. UCL report: compliant with FS-209E and Chinese GMP standards
7. Working hours: 8 hours
8. Working environment: Temperature: 10-35 ℃; Relative humidity: 20-75% RH
9. Range and accuracy of measuring temperature and humidity: (optional) Temperature: 0-50 ℃± 1 ℃; Humidity: 0-100% RH ± 5%
10. Dimensions: 285 × 130 × 380
11. Particle size channel:0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μ m (counting six particle sizes simultaneously)
3、 Instrument features
1. Equipped with a high-performance battery, it can be used for both AC and DC, and has a long service life; High detection accuracy;
2. Built in thermal printer, which can be converted to M3 printing;
3. Small size, light weight, easy operation, and convenient use;
4,Mask factoryDust particle counter2.83LShort self-cleaning time, with built-in flow meter;
5,Equipped with storage function, UCL confidence value, and instrument level alarm function.