E-mail
317650740@qq.com
-
Phone
13956326558
-
Address
No. 20 Renhe South Road, Tianchang City, Anhui Province
Anhui Tiankang (Group) Co., Ltd
317650740@qq.com
13956326558
No. 20 Renhe South Road, Tianchang City, Anhui Province
range specification
category |
code name |
graduation mark |
Temperature measurement range ℃ |
accuracy class |
Allowable deviation △ t |
Nickel chromium nickel silicon |
WRNT |
K |
0-800 |
I |
± 1.5 ℃ or ± 0.004 ∣ t ∣ |
II |
± 2.5 ℃ or ± 0.0075 ∣ t ∣ |
||||
Nickel chromium copper nickel |
WRET |
E |
0-600 |
I |
± 1.5 ℃ or ± 0.004 ∣ t ∣ |
II |
± 2.5 ℃ or ± 0.0075 ∣ t ∣ |
||||
Copper Copper Nickel |
WRCT |
T |
-40-350 |
I |
± 0.5 ℃ or ± 0.004 ∣ t ∣ |
II |
± 1 ℃ or ± 0.75% t |
||||
rtd |
WZPT |
Pt100 |
-200-500 |
* |
±(0.15+0.002∣t∣) |
Grade B |
±(0.30+0.005∣t∣) |
||||
copper resistance |
WZCT |
Cu50 |
-50-100 |
II |
±(0.30+6.0X10-3t) |
Note: "t" represents the measured temperature of the temperature sensing element, while for platinum and copper resistors, it represents the measured temperature of the temperature sensing element.
Nominal Pressure
Generally refers to the static external pressure that the protective tube can withstand without breaking at room temperature, and the test pressure is generally 1.5 times the nominal pressure. In fact, the allowable working pressure is not only related to the material, diameter, and wall thickness of the protective tube, but also to its structural form, installation method, insertion depth, as well as the flow rate and type of the measured medium.
Thermocouple insulation resistance:
The test voltage for room temperature insulation resistance is 500V DC. The atmospheric conditions for measuring room temperature insulation resistance are: temperature 15-35 ℃, relative humidity 45%, and atmospheric pressure 86-106Kpa.
For thermocouples with a length exceeding 1 meter, the product of their insulation resistance at room temperature and their length shall not be less than 100 megaohms per meter,
Namely: Rr · L ≥ 100M Ω m L > 1m
In the formula: Rr - the insulation resistance value of the thermocouple at room temperature, M Ω;
The length of the L-thermocouple, m。
For thermocouples with a length of 1 meter or less, their insulation resistance at room temperature should not be less than 100 M Ω.
Thermal resistance insulation resistance:
The test voltage for insulation resistance at room temperature can be any value between 10-100V DC, the ambient temperature should be within the range of 15-35 ℃, the relative humidity should not exceed 80%, and the insulation resistance value at room temperature should not be less than 100 M Ω.